Comparative study between methods of pre-operative measurement of intramedullary nail length in fracture shaft of femur

Introduction Fractures shaft of the femur are among the most common fractures encountered in orthopaedic practice. Locked femoral intramedullary nailing is accepted as the standard treatment of choice for most femoral shaft fractures. As most of operation room inventory in our setup does not hav...

Full description

Saved in:
Bibliographic Details
Main Author: Mat Rodi, Mohd Saiful Adzuwan
Format: Thesis
Language:English
Published: 2015
Subjects:
Online Access:http://eprints.usm.my/39817/1/Dr_Mohd_Saiful_Adzuwan_Mat_Rodi-24_pages.pdf
http://eprints.usm.my/39817/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.39817
record_format eprints
spelling my.usm.eprints.39817 http://eprints.usm.my/39817/ Comparative study between methods of pre-operative measurement of intramedullary nail length in fracture shaft of femur Mat Rodi, Mohd Saiful Adzuwan RD701-811 Orthopedic surgery Introduction Fractures shaft of the femur are among the most common fractures encountered in orthopaedic practice. Locked femoral intramedullary nailing is accepted as the standard treatment of choice for most femoral shaft fractures. As most of operation room inventory in our setup does not have a complete range of the intramedullary nails, most surgeons estimate the size and length of the intramedullary nail preoperatively by various methods and keep a size bigger and smaller the assessed length for the planned surgery. Objective The main objective was to study the accuracy and validity of pre-operative clinical measurement of intramedullary nail length in fracture shaft of femur. We also studied the inter-observer reliability of each method tested. Methodology This research was a prospective randomized study that involved analysis of data taken clinically as well from plain radiograph. This study was done as a clinical assessment. One hundred and thirty patients were enrolled. Measurement of femoral shaft was performed by using three different methods, which were tested by three investigators from different level of medical background. Method 1 was measurement taken from the tip of greater trochanter to the lateral knee joint line of the opposite limb minus 2 centimeters (standard AO), Method 2 was measurement taken from the tip of the greater trochanter to the upper pole of patella on the opposite limb (alternative AO) and Method 3 was measurement taken from the tip of the olecranon process to the tip of the little finger on any side (the “tip-to-tip” method). Results Analysis showed that there were significant differences in inter-observer variability in the measurement taken using Method 1 (p = 0.0001) and Method 2 (p = 0.0001) but not in Method 3 (p = 0.763). All methods were well correlated with radiology measurements. The average length of measurement for Method 3 were 1.7 cm longer in female patients and 2.5 cm longer in male patients than average length of measurement by radiograph. Conclusions Method 3 is valid and can be applied in clinical practice with accuracy by subtracting 1.7 cm from the measurement in a female patient and 2.5 cm from the measurement in a male patient. It also has significant inter-observer reliability. It is simple to perform, radiation-free and can be applied in a patient with bilateral femur fractures. 2015 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/39817/1/Dr_Mohd_Saiful_Adzuwan_Mat_Rodi-24_pages.pdf Mat Rodi, Mohd Saiful Adzuwan (2015) Comparative study between methods of pre-operative measurement of intramedullary nail length in fracture shaft of femur. Masters thesis, Universiti Sains Malaysia.
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic RD701-811 Orthopedic surgery
spellingShingle RD701-811 Orthopedic surgery
Mat Rodi, Mohd Saiful Adzuwan
Comparative study between methods of pre-operative measurement of intramedullary nail length in fracture shaft of femur
description Introduction Fractures shaft of the femur are among the most common fractures encountered in orthopaedic practice. Locked femoral intramedullary nailing is accepted as the standard treatment of choice for most femoral shaft fractures. As most of operation room inventory in our setup does not have a complete range of the intramedullary nails, most surgeons estimate the size and length of the intramedullary nail preoperatively by various methods and keep a size bigger and smaller the assessed length for the planned surgery. Objective The main objective was to study the accuracy and validity of pre-operative clinical measurement of intramedullary nail length in fracture shaft of femur. We also studied the inter-observer reliability of each method tested. Methodology This research was a prospective randomized study that involved analysis of data taken clinically as well from plain radiograph. This study was done as a clinical assessment. One hundred and thirty patients were enrolled. Measurement of femoral shaft was performed by using three different methods, which were tested by three investigators from different level of medical background. Method 1 was measurement taken from the tip of greater trochanter to the lateral knee joint line of the opposite limb minus 2 centimeters (standard AO), Method 2 was measurement taken from the tip of the greater trochanter to the upper pole of patella on the opposite limb (alternative AO) and Method 3 was measurement taken from the tip of the olecranon process to the tip of the little finger on any side (the “tip-to-tip” method). Results Analysis showed that there were significant differences in inter-observer variability in the measurement taken using Method 1 (p = 0.0001) and Method 2 (p = 0.0001) but not in Method 3 (p = 0.763). All methods were well correlated with radiology measurements. The average length of measurement for Method 3 were 1.7 cm longer in female patients and 2.5 cm longer in male patients than average length of measurement by radiograph. Conclusions Method 3 is valid and can be applied in clinical practice with accuracy by subtracting 1.7 cm from the measurement in a female patient and 2.5 cm from the measurement in a male patient. It also has significant inter-observer reliability. It is simple to perform, radiation-free and can be applied in a patient with bilateral femur fractures.
format Thesis
author Mat Rodi, Mohd Saiful Adzuwan
author_facet Mat Rodi, Mohd Saiful Adzuwan
author_sort Mat Rodi, Mohd Saiful Adzuwan
title Comparative study between methods of pre-operative measurement of intramedullary nail length in fracture shaft of femur
title_short Comparative study between methods of pre-operative measurement of intramedullary nail length in fracture shaft of femur
title_full Comparative study between methods of pre-operative measurement of intramedullary nail length in fracture shaft of femur
title_fullStr Comparative study between methods of pre-operative measurement of intramedullary nail length in fracture shaft of femur
title_full_unstemmed Comparative study between methods of pre-operative measurement of intramedullary nail length in fracture shaft of femur
title_sort comparative study between methods of pre-operative measurement of intramedullary nail length in fracture shaft of femur
publishDate 2015
url http://eprints.usm.my/39817/1/Dr_Mohd_Saiful_Adzuwan_Mat_Rodi-24_pages.pdf
http://eprints.usm.my/39817/
_version_ 1643709763741024256
score 13.211869