Computation of energy absorption and residual voltage in a fourth rail LRT station arresters in EMTP-RV: a comparative study

This paper presents a study on the performance of a fourth rail direct current (DC) urban transit affected by an indirect lightning strike. The indirect lightning strike was replicated and represented by a lightning-induced overvoltage by means of the Rusck model, with the sum of two Heidler functio...

Full description

Saved in:
Bibliographic Details
Main Authors: Abd Rahman, Farah Asyikin, Ab Kadir, Mohd Zainal Abidin, Ungku Amirulddin Al Amin, Ungku Anisa, Osman, Miszaina
Format: Article
Published: Springer 2021
Online Access:http://psasir.upm.edu.my/id/eprint/96495/
https://link.springer.com/article/10.1007/s40864-021-00143-w
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.96495
record_format eprints
spelling my.upm.eprints.964952023-01-11T08:50:48Z http://psasir.upm.edu.my/id/eprint/96495/ Computation of energy absorption and residual voltage in a fourth rail LRT station arresters in EMTP-RV: a comparative study Abd Rahman, Farah Asyikin Ab Kadir, Mohd Zainal Abidin Ungku Amirulddin Al Amin, Ungku Anisa Osman, Miszaina This paper presents a study on the performance of a fourth rail direct current (DC) urban transit affected by an indirect lightning strike. The indirect lightning strike was replicated and represented by a lightning-induced overvoltage by means of the Rusck model, with the sum of two Heidler functions as its lightning channel base current input, on a perfect conducting ground. This study aims to determine whether an indirect lightning strike has any influence with regard to the performance of the LRT Kelana Jaya line, a fourth rail DC urban transit station arrester. The simulations were carried out using the Electromagnetic Transients Program–Restructured Version (EMTP–RV), which includes the comparison performance results between the 3EB4-010 arrester and PDTA09 arrester when induced by a 90 kA (9/200 µs). The results demonstrated that the PDTA09 arrester showed better coordination with the insulated rail bracket of the fourth rail. It allowed a lower residual voltage and a more dynamic response, eventually resulting in better voltage gradient in the pre-breakdown region and decreased residual voltage ratio in the high current region. Springer 2021 Article PeerReviewed Abd Rahman, Farah Asyikin and Ab Kadir, Mohd Zainal Abidin and Ungku Amirulddin Al Amin, Ungku Anisa and Osman, Miszaina (2021) Computation of energy absorption and residual voltage in a fourth rail LRT station arresters in EMTP-RV: a comparative study. Urban Rail Transit, 7. 71 - 83. ISSN 2199-6687; ESSN: 2199-6679 https://link.springer.com/article/10.1007/s40864-021-00143-w 10.1007/s40864-021-00143-w
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
description This paper presents a study on the performance of a fourth rail direct current (DC) urban transit affected by an indirect lightning strike. The indirect lightning strike was replicated and represented by a lightning-induced overvoltage by means of the Rusck model, with the sum of two Heidler functions as its lightning channel base current input, on a perfect conducting ground. This study aims to determine whether an indirect lightning strike has any influence with regard to the performance of the LRT Kelana Jaya line, a fourth rail DC urban transit station arrester. The simulations were carried out using the Electromagnetic Transients Program–Restructured Version (EMTP–RV), which includes the comparison performance results between the 3EB4-010 arrester and PDTA09 arrester when induced by a 90 kA (9/200 µs). The results demonstrated that the PDTA09 arrester showed better coordination with the insulated rail bracket of the fourth rail. It allowed a lower residual voltage and a more dynamic response, eventually resulting in better voltage gradient in the pre-breakdown region and decreased residual voltage ratio in the high current region.
format Article
author Abd Rahman, Farah Asyikin
Ab Kadir, Mohd Zainal Abidin
Ungku Amirulddin Al Amin, Ungku Anisa
Osman, Miszaina
spellingShingle Abd Rahman, Farah Asyikin
Ab Kadir, Mohd Zainal Abidin
Ungku Amirulddin Al Amin, Ungku Anisa
Osman, Miszaina
Computation of energy absorption and residual voltage in a fourth rail LRT station arresters in EMTP-RV: a comparative study
author_facet Abd Rahman, Farah Asyikin
Ab Kadir, Mohd Zainal Abidin
Ungku Amirulddin Al Amin, Ungku Anisa
Osman, Miszaina
author_sort Abd Rahman, Farah Asyikin
title Computation of energy absorption and residual voltage in a fourth rail LRT station arresters in EMTP-RV: a comparative study
title_short Computation of energy absorption and residual voltage in a fourth rail LRT station arresters in EMTP-RV: a comparative study
title_full Computation of energy absorption and residual voltage in a fourth rail LRT station arresters in EMTP-RV: a comparative study
title_fullStr Computation of energy absorption and residual voltage in a fourth rail LRT station arresters in EMTP-RV: a comparative study
title_full_unstemmed Computation of energy absorption and residual voltage in a fourth rail LRT station arresters in EMTP-RV: a comparative study
title_sort computation of energy absorption and residual voltage in a fourth rail lrt station arresters in emtp-rv: a comparative study
publisher Springer
publishDate 2021
url http://psasir.upm.edu.my/id/eprint/96495/
https://link.springer.com/article/10.1007/s40864-021-00143-w
_version_ 1755873907272843264
score 13.211869