Development of in-pipe water pollution detection system focusing on pH contaminant

Developing an in-pipe water pollution detection system ensures that the contaminated water will not enter the system in the event of water pollution, hence reducing the possibility of a water crisis. In this research, the design of the system was completed using SOLIDWORKS. ANSYS software was used f...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdul Aziz, Nuraini, Chemani@Jumani, Muhammad Aiman, Anuari, Muhammad Safwan, Shamsuddin, Muhammad Aiman Hakimi, Mohamed Ariff, Azmah Hanim
Format: Article
Language:English
Published: Universiti Putra Malaysia Press 2022
Online Access:http://psasir.upm.edu.my/id/eprint/92587/1/10%20JST-3179-2021.pdf
http://psasir.upm.edu.my/id/eprint/92587/
http://www.pertanika.upm.edu.my/pjst/browse/regular-issue?article=JST-3179-2021