Electrocoagulation for removal of chemical oxygen demand and heavy metals in leachate from Jeram sanitary landfill, Malaysia

The increasing amount of solid waste generation in Malaysia has become a problem in Solid Waste Management (SWM), since it creates serious impact to the environment especially on the landfill site. The generation of leachate during landfilling operation may impair environment by contaminating sur...

Full description

Saved in:
Bibliographic Details
Main Author: Jotin, Rosie
Format: Thesis
Language:English
Published: 2013
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/91441/1/FPAS%202013%205%20-%20IR.pdf
http://psasir.upm.edu.my/id/eprint/91441/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.91441
record_format eprints
spelling my.upm.eprints.914412021-12-15T08:03:39Z http://psasir.upm.edu.my/id/eprint/91441/ Electrocoagulation for removal of chemical oxygen demand and heavy metals in leachate from Jeram sanitary landfill, Malaysia Jotin, Rosie The increasing amount of solid waste generation in Malaysia has become a problem in Solid Waste Management (SWM), since it creates serious impact to the environment especially on the landfill site. The generation of leachate during landfilling operation may impair environment by contaminating surface and ground water system either directly or indirectly from the site. Eventhough at a present most sanitary landfill is equipt with high level of leachate treatment facilities, leachate is still considered as a significant source of environmental pollution because their constituent that are difficult to be treated successfully. Therefore, innovative, cheap and effective techniques of purifying landfill leachate are needed before the leachate being discharged into water systems. The present study was conducted to investigate the efficiency of electrocoagulation processes in the removal of Chemical Oxygen Demand (COD) and heavy metals (Zn and Cu) from Jeram Sanitary Landfill leachate influenced by several parameters, thus proposing the optimum condition for pollutants removal. The electrocoagulation reaction was conducted in a batch reactor using aluminum as sacrificial electrodes. The effecting parameters such as applied voltage, conductivity and initial pH were studied to determine the condition of optimum removal. The variation of conductivity, pH and temperature also were noted during the electrocoagulation process. In this process, samples of 25 mL were taken out from the beaker at 10, 20, 40, 60, 80 and 100 minutes of electrolysis time. From the results obtained, the optimum operation conditions of the electrocoagulation process for the removal of COD, Zn and Cu was found to be as follows: applied voltage of 10 V 0=0.0207 m.A/cm"), conductivity of 28.00 mS/cm or lower, initial pH of 6 and 100 minuntes of electrolysis time. At these conditions, approximately, 61.86 % COD, 74.41 % Zn and 97.47 % Cu removals can be reached. In this study, the electrocoagulation process has proved to be effective in the removal of COD and heavy metals from sanitary landfill leachate. 2013-06 Thesis NonPeerReviewed text en http://psasir.upm.edu.my/id/eprint/91441/1/FPAS%202013%205%20-%20IR.pdf Jotin, Rosie (2013) Electrocoagulation for removal of chemical oxygen demand and heavy metals in leachate from Jeram sanitary landfill, Malaysia. Masters thesis, Universiti Putra Malaysia. Sanitary landfills - Leaching - Malaysia Heavy metals - Environmental aspects - Malaysia Electrocoagulation - Research
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
topic Sanitary landfills - Leaching - Malaysia
Heavy metals - Environmental aspects - Malaysia
Electrocoagulation - Research
spellingShingle Sanitary landfills - Leaching - Malaysia
Heavy metals - Environmental aspects - Malaysia
Electrocoagulation - Research
Jotin, Rosie
Electrocoagulation for removal of chemical oxygen demand and heavy metals in leachate from Jeram sanitary landfill, Malaysia
description The increasing amount of solid waste generation in Malaysia has become a problem in Solid Waste Management (SWM), since it creates serious impact to the environment especially on the landfill site. The generation of leachate during landfilling operation may impair environment by contaminating surface and ground water system either directly or indirectly from the site. Eventhough at a present most sanitary landfill is equipt with high level of leachate treatment facilities, leachate is still considered as a significant source of environmental pollution because their constituent that are difficult to be treated successfully. Therefore, innovative, cheap and effective techniques of purifying landfill leachate are needed before the leachate being discharged into water systems. The present study was conducted to investigate the efficiency of electrocoagulation processes in the removal of Chemical Oxygen Demand (COD) and heavy metals (Zn and Cu) from Jeram Sanitary Landfill leachate influenced by several parameters, thus proposing the optimum condition for pollutants removal. The electrocoagulation reaction was conducted in a batch reactor using aluminum as sacrificial electrodes. The effecting parameters such as applied voltage, conductivity and initial pH were studied to determine the condition of optimum removal. The variation of conductivity, pH and temperature also were noted during the electrocoagulation process. In this process, samples of 25 mL were taken out from the beaker at 10, 20, 40, 60, 80 and 100 minutes of electrolysis time. From the results obtained, the optimum operation conditions of the electrocoagulation process for the removal of COD, Zn and Cu was found to be as follows: applied voltage of 10 V 0=0.0207 m.A/cm"), conductivity of 28.00 mS/cm or lower, initial pH of 6 and 100 minuntes of electrolysis time. At these conditions, approximately, 61.86 % COD, 74.41 % Zn and 97.47 % Cu removals can be reached. In this study, the electrocoagulation process has proved to be effective in the removal of COD and heavy metals from sanitary landfill leachate.
format Thesis
author Jotin, Rosie
author_facet Jotin, Rosie
author_sort Jotin, Rosie
title Electrocoagulation for removal of chemical oxygen demand and heavy metals in leachate from Jeram sanitary landfill, Malaysia
title_short Electrocoagulation for removal of chemical oxygen demand and heavy metals in leachate from Jeram sanitary landfill, Malaysia
title_full Electrocoagulation for removal of chemical oxygen demand and heavy metals in leachate from Jeram sanitary landfill, Malaysia
title_fullStr Electrocoagulation for removal of chemical oxygen demand and heavy metals in leachate from Jeram sanitary landfill, Malaysia
title_full_unstemmed Electrocoagulation for removal of chemical oxygen demand and heavy metals in leachate from Jeram sanitary landfill, Malaysia
title_sort electrocoagulation for removal of chemical oxygen demand and heavy metals in leachate from jeram sanitary landfill, malaysia
publishDate 2013
url http://psasir.upm.edu.my/id/eprint/91441/1/FPAS%202013%205%20-%20IR.pdf
http://psasir.upm.edu.my/id/eprint/91441/
_version_ 1720438540849905664
score 13.222552