Determining islanding operation using micro grid phasor measurement unit parameters
For improving the reliability of the micro grid network, a robust islanding detection algorithm is required. For creating a vigorous islanding detection algorithm voltage angle and current angle should be detected appropriately from the grid. The main objective of this research is to determine and c...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
World Academy of Research in Science and Engineering
2020
|
Online Access: | http://psasir.upm.edu.my/id/eprint/88405/1/ABSTRACT.pdf http://psasir.upm.edu.my/id/eprint/88405/ http://www.warse.org/IJETER/archives/archivesDetiles/?heading=Vol%208%20No%201.1%20(2020)%20S%20I |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.upm.eprints.88405 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.884052021-12-27T04:21:32Z http://psasir.upm.edu.my/id/eprint/88405/ Determining islanding operation using micro grid phasor measurement unit parameters Arefin, Ahmed Amirul Md Hasan, Khairul Nisak Romlie, Mohd Fakhizan Abdullah, Mohd Faris Ali, Mohd Nazri Othman, Mohammad Lutfi For improving the reliability of the micro grid network, a robust islanding detection algorithm is required. For creating a vigorous islanding detection algorithm voltage angle and current angle should be detected appropriately from the grid. The main objective of this research is to determine and compare the voltage angle and current angle with normal operation and islanding operation of the micro grid to develop multilevel islanding detection algorithm to ensure the higher reliability. In this work, IEEE 30 bus network phasor measurement unit parameters have been determined in Power World Simulator. The result shows that the proposed methodology can appropriately determine the islanding event and the comparative study shows an incredible change in phasor measurement unit parameters when grid goes on islanding operation. World Academy of Research in Science and Engineering 2020 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/88405/1/ABSTRACT.pdf Arefin, Ahmed Amirul and Md Hasan, Khairul Nisak and Romlie, Mohd Fakhizan and Abdullah, Mohd Faris and Ali, Mohd Nazri and Othman, Mohammad Lutfi (2020) Determining islanding operation using micro grid phasor measurement unit parameters. International Journal of Emerging Trends in Engineering Research, 8 (1 spec. 1). 97 - 101. ISSN 2347-3983 http://www.warse.org/IJETER/archives/archivesDetiles/?heading=Vol%208%20No%201.1%20(2020)%20S%20I 10.30534/ijeter/2020/1581.12020 |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
For improving the reliability of the micro grid network, a robust islanding detection algorithm is required. For creating a vigorous islanding detection algorithm voltage angle and current angle should be detected appropriately from the grid. The main objective of this research is to determine and compare the voltage angle and current angle with normal operation and islanding operation of the micro grid to develop multilevel islanding detection algorithm to ensure the higher reliability. In this work, IEEE 30 bus network phasor measurement unit parameters have been determined in Power World Simulator. The result shows that the proposed methodology can appropriately determine the islanding event and the comparative study shows an incredible change in phasor measurement unit parameters when grid goes on islanding operation. |
format |
Article |
author |
Arefin, Ahmed Amirul Md Hasan, Khairul Nisak Romlie, Mohd Fakhizan Abdullah, Mohd Faris Ali, Mohd Nazri Othman, Mohammad Lutfi |
spellingShingle |
Arefin, Ahmed Amirul Md Hasan, Khairul Nisak Romlie, Mohd Fakhizan Abdullah, Mohd Faris Ali, Mohd Nazri Othman, Mohammad Lutfi Determining islanding operation using micro grid phasor measurement unit parameters |
author_facet |
Arefin, Ahmed Amirul Md Hasan, Khairul Nisak Romlie, Mohd Fakhizan Abdullah, Mohd Faris Ali, Mohd Nazri Othman, Mohammad Lutfi |
author_sort |
Arefin, Ahmed Amirul |
title |
Determining islanding operation using micro grid phasor
measurement unit parameters |
title_short |
Determining islanding operation using micro grid phasor
measurement unit parameters |
title_full |
Determining islanding operation using micro grid phasor
measurement unit parameters |
title_fullStr |
Determining islanding operation using micro grid phasor
measurement unit parameters |
title_full_unstemmed |
Determining islanding operation using micro grid phasor
measurement unit parameters |
title_sort |
determining islanding operation using micro grid phasor
measurement unit parameters |
publisher |
World Academy of Research in Science and Engineering |
publishDate |
2020 |
url |
http://psasir.upm.edu.my/id/eprint/88405/1/ABSTRACT.pdf http://psasir.upm.edu.my/id/eprint/88405/ http://www.warse.org/IJETER/archives/archivesDetiles/?heading=Vol%208%20No%201.1%20(2020)%20S%20I |
_version_ |
1724075506462097408 |
score |
13.211869 |