Evaluation of magnetic susceptibility artefact induced by personal care product with gold nanoparticles on brain magnetic resonance (MRI) images

MRI is an important diagnostic imaging tool as it provides excellent soft tissue contrast resolution. Artefact in MRI is an undesirable appearance in the image that affect the image quality and may hinder true diagnosis of the pathological events. Gold in bulk form does not cause any artefact in MRI...

Full description

Saved in:
Bibliographic Details
Main Authors: Zaini, Nor Syaza, Mohd, Zanariah, Abdul Karim, Muhammad Khalis
Format: Article
Published: Institute of Physics Publishing 2019
Online Access:http://psasir.upm.edu.my/id/eprint/79761/
https://iopscience.iop.org/article/10.1088/1742-6596/1248/1/012011
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.79761
record_format eprints
spelling my.upm.eprints.797612022-11-02T02:56:05Z http://psasir.upm.edu.my/id/eprint/79761/ Evaluation of magnetic susceptibility artefact induced by personal care product with gold nanoparticles on brain magnetic resonance (MRI) images Zaini, Nor Syaza Mohd, Zanariah Abdul Karim, Muhammad Khalis MRI is an important diagnostic imaging tool as it provides excellent soft tissue contrast resolution. Artefact in MRI is an undesirable appearance in the image that affect the image quality and may hinder true diagnosis of the pathological events. Gold in bulk form does not cause any artefact in MRI as it is diamagnetic whereas in its nanoscale version, it was proven to pose magnetic properties. Previous studies also shown that some personal care products (PCPs) produce artefact in MR images due to the presence of metallic compounds in the PCP. Hence, this study was conducted to investigate the effect of PCP with gold nanoparticles (AuNPs) on brain MRI images. The study was conducted using 1.5 Tesla MRI system where moisturiser and compact powder with AuNPs were tested. The products were applied onto the micropore tape attached to the MRI water phantom. The phantom was placed in an RF coil at the isocentre of the MRI bore and scanned using T1-weighted fast-spin-echo (FSE), T2-weighted FSE and fluid attenuated inversion recovery (FLAIR) sequences. The images were evaluated using Visual Grading Analysis (VGA) checklist by two radiologists. Based on the VGA score, brain MRI images in moisturiser group were all scored ‘1’ which indicate minimal artefact with only loss of fine details seen. Whereas, brain MRI images of compact powder group were all scored ‘0’ which indicate no artefact seen. Therefore, it can be concluded that PCP with AuNPs produce little to no artefact on brain MRI images, thus, there will be no need for the patient who wears PCP with AuNPs to clean their face prior to brain MRI examination. Institute of Physics Publishing 2019 Article PeerReviewed Zaini, Nor Syaza and Mohd, Zanariah and Abdul Karim, Muhammad Khalis (2019) Evaluation of magnetic susceptibility artefact induced by personal care product with gold nanoparticles on brain magnetic resonance (MRI) images. Journal of Physics: Conference Series, 1248 (1). pp. 1-7. ISSN 1742-6588; ESSN: 1742-6596 https://iopscience.iop.org/article/10.1088/1742-6596/1248/1/012011 10.1088/1742-6596/1248/1/012011
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
description MRI is an important diagnostic imaging tool as it provides excellent soft tissue contrast resolution. Artefact in MRI is an undesirable appearance in the image that affect the image quality and may hinder true diagnosis of the pathological events. Gold in bulk form does not cause any artefact in MRI as it is diamagnetic whereas in its nanoscale version, it was proven to pose magnetic properties. Previous studies also shown that some personal care products (PCPs) produce artefact in MR images due to the presence of metallic compounds in the PCP. Hence, this study was conducted to investigate the effect of PCP with gold nanoparticles (AuNPs) on brain MRI images. The study was conducted using 1.5 Tesla MRI system where moisturiser and compact powder with AuNPs were tested. The products were applied onto the micropore tape attached to the MRI water phantom. The phantom was placed in an RF coil at the isocentre of the MRI bore and scanned using T1-weighted fast-spin-echo (FSE), T2-weighted FSE and fluid attenuated inversion recovery (FLAIR) sequences. The images were evaluated using Visual Grading Analysis (VGA) checklist by two radiologists. Based on the VGA score, brain MRI images in moisturiser group were all scored ‘1’ which indicate minimal artefact with only loss of fine details seen. Whereas, brain MRI images of compact powder group were all scored ‘0’ which indicate no artefact seen. Therefore, it can be concluded that PCP with AuNPs produce little to no artefact on brain MRI images, thus, there will be no need for the patient who wears PCP with AuNPs to clean their face prior to brain MRI examination.
format Article
author Zaini, Nor Syaza
Mohd, Zanariah
Abdul Karim, Muhammad Khalis
spellingShingle Zaini, Nor Syaza
Mohd, Zanariah
Abdul Karim, Muhammad Khalis
Evaluation of magnetic susceptibility artefact induced by personal care product with gold nanoparticles on brain magnetic resonance (MRI) images
author_facet Zaini, Nor Syaza
Mohd, Zanariah
Abdul Karim, Muhammad Khalis
author_sort Zaini, Nor Syaza
title Evaluation of magnetic susceptibility artefact induced by personal care product with gold nanoparticles on brain magnetic resonance (MRI) images
title_short Evaluation of magnetic susceptibility artefact induced by personal care product with gold nanoparticles on brain magnetic resonance (MRI) images
title_full Evaluation of magnetic susceptibility artefact induced by personal care product with gold nanoparticles on brain magnetic resonance (MRI) images
title_fullStr Evaluation of magnetic susceptibility artefact induced by personal care product with gold nanoparticles on brain magnetic resonance (MRI) images
title_full_unstemmed Evaluation of magnetic susceptibility artefact induced by personal care product with gold nanoparticles on brain magnetic resonance (MRI) images
title_sort evaluation of magnetic susceptibility artefact induced by personal care product with gold nanoparticles on brain magnetic resonance (mri) images
publisher Institute of Physics Publishing
publishDate 2019
url http://psasir.upm.edu.my/id/eprint/79761/
https://iopscience.iop.org/article/10.1088/1742-6596/1248/1/012011
_version_ 1748704620748734464
score 13.211869