Distribution of dissolved and particulate Fe in an estuarine system at Bagan Pasir, Perak

The distribution of dissolved iron (dFe) and particulate iron in the estuarine system was studied where in-situ water sampling stations were selected at Bagan Pasir, Perak. The concentration of dFe was 1.17±0.28 mg/L on average at the estuary, while in freshwater samples its concentration was 0.08±0...

Full description

Saved in:
Bibliographic Details
Main Authors: Muhamad Kamel, Syaza Syafiqah, Mohamed @ Mohd Ramli, Khairul Nizam, Mohamat Yusuff, Ferdius @ Ferdaus, Amiruddin, Abd Muhaimin
Format: Article
Language:English
Published: Universiti Putra Malaysia Press 2019
Online Access:http://psasir.upm.edu.my/id/eprint/76344/1/49%20JST%28S%29-0486-2019.pdf
http://psasir.upm.edu.my/id/eprint/76344/
http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2027%20(4)%20Oct.%202019/49%20JST(S)-0486-2019.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.76344
record_format eprints
spelling my.upm.eprints.763442020-02-04T03:58:48Z http://psasir.upm.edu.my/id/eprint/76344/ Distribution of dissolved and particulate Fe in an estuarine system at Bagan Pasir, Perak Muhamad Kamel, Syaza Syafiqah Mohamed @ Mohd Ramli, Khairul Nizam Mohamat Yusuff, Ferdius @ Ferdaus Amiruddin, Abd Muhaimin The distribution of dissolved iron (dFe) and particulate iron in the estuarine system was studied where in-situ water sampling stations were selected at Bagan Pasir, Perak. The concentration of dFe was 1.17±0.28 mg/L on average at the estuary, while in freshwater samples its concentration was 0.08±0.00 mg/L. This study found that the concentration of particulate Fe in freshwater system was higher than that in the estuary system. The Fe concentration was 0.95±0.03 mg/kg and 0.80±0.18 mg/kg at the freshwater and estuary systems, respectively. We have applied a distribution coefficient (KD) in order to quantify the partitioning of Fe between the particulate (>0.45 µm) and dissolved (<0.45 µm) phases. The KD value of Fe in the freshwater system was much higher compared to that in the estuary, where the KD value was 12.18 in freshwater and 0.48 -1.31 in the estuary. This indicated that Fe in this area has a strong affinity with the particulate phase in a freshwater system and this is probably due to the anthropogenic input. On the other hand, Fe may exist in colloidal or organic ligands which probably originate from surface sediment or a biological process in water columns at the estuarine area. Universiti Putra Malaysia Press 2019 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/76344/1/49%20JST%28S%29-0486-2019.pdf Muhamad Kamel, Syaza Syafiqah and Mohamed @ Mohd Ramli, Khairul Nizam and Mohamat Yusuff, Ferdius @ Ferdaus and Amiruddin, Abd Muhaimin (2019) Distribution of dissolved and particulate Fe in an estuarine system at Bagan Pasir, Perak. Pertanika Journal of Science & Technology, 27 (4). pp. 2317-2331. ISSN 0128-7680; ESSN: 2231-8526 http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2027%20(4)%20Oct.%202019/49%20JST(S)-0486-2019.pdf
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description The distribution of dissolved iron (dFe) and particulate iron in the estuarine system was studied where in-situ water sampling stations were selected at Bagan Pasir, Perak. The concentration of dFe was 1.17±0.28 mg/L on average at the estuary, while in freshwater samples its concentration was 0.08±0.00 mg/L. This study found that the concentration of particulate Fe in freshwater system was higher than that in the estuary system. The Fe concentration was 0.95±0.03 mg/kg and 0.80±0.18 mg/kg at the freshwater and estuary systems, respectively. We have applied a distribution coefficient (KD) in order to quantify the partitioning of Fe between the particulate (>0.45 µm) and dissolved (<0.45 µm) phases. The KD value of Fe in the freshwater system was much higher compared to that in the estuary, where the KD value was 12.18 in freshwater and 0.48 -1.31 in the estuary. This indicated that Fe in this area has a strong affinity with the particulate phase in a freshwater system and this is probably due to the anthropogenic input. On the other hand, Fe may exist in colloidal or organic ligands which probably originate from surface sediment or a biological process in water columns at the estuarine area.
format Article
author Muhamad Kamel, Syaza Syafiqah
Mohamed @ Mohd Ramli, Khairul Nizam
Mohamat Yusuff, Ferdius @ Ferdaus
Amiruddin, Abd Muhaimin
spellingShingle Muhamad Kamel, Syaza Syafiqah
Mohamed @ Mohd Ramli, Khairul Nizam
Mohamat Yusuff, Ferdius @ Ferdaus
Amiruddin, Abd Muhaimin
Distribution of dissolved and particulate Fe in an estuarine system at Bagan Pasir, Perak
author_facet Muhamad Kamel, Syaza Syafiqah
Mohamed @ Mohd Ramli, Khairul Nizam
Mohamat Yusuff, Ferdius @ Ferdaus
Amiruddin, Abd Muhaimin
author_sort Muhamad Kamel, Syaza Syafiqah
title Distribution of dissolved and particulate Fe in an estuarine system at Bagan Pasir, Perak
title_short Distribution of dissolved and particulate Fe in an estuarine system at Bagan Pasir, Perak
title_full Distribution of dissolved and particulate Fe in an estuarine system at Bagan Pasir, Perak
title_fullStr Distribution of dissolved and particulate Fe in an estuarine system at Bagan Pasir, Perak
title_full_unstemmed Distribution of dissolved and particulate Fe in an estuarine system at Bagan Pasir, Perak
title_sort distribution of dissolved and particulate fe in an estuarine system at bagan pasir, perak
publisher Universiti Putra Malaysia Press
publishDate 2019
url http://psasir.upm.edu.my/id/eprint/76344/1/49%20JST%28S%29-0486-2019.pdf
http://psasir.upm.edu.my/id/eprint/76344/
http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2027%20(4)%20Oct.%202019/49%20JST(S)-0486-2019.pdf
_version_ 1662756512448118784
score 13.211869