Development of convenient quality control analysis method and improvement on the radiochemical yield using F-18-Labelled choline

Prostate cancer continues to be the most prevalent cancer in men in Malaysia. It is anticipated that the number of prostate cancer sufferers’ will increase in future. In the case of Positron Emission Tomography / Computed Tomography (PET/CT), clinicians cannot solely rely on F-18 Fluorodeoxyglucose...

Full description

Saved in:
Bibliographic Details
Main Author: Hassan, Muhammad Hishar
Format: Thesis
Language:English
Published: 2016
Online Access:http://psasir.upm.edu.my/id/eprint/75302/1/FPSK%28M%29%202016%2027%20IR.pdf
http://psasir.upm.edu.my/id/eprint/75302/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.75302
record_format eprints
spelling my.upm.eprints.753022019-10-17T08:27:55Z http://psasir.upm.edu.my/id/eprint/75302/ Development of convenient quality control analysis method and improvement on the radiochemical yield using F-18-Labelled choline Hassan, Muhammad Hishar Prostate cancer continues to be the most prevalent cancer in men in Malaysia. It is anticipated that the number of prostate cancer sufferers’ will increase in future. In the case of Positron Emission Tomography / Computed Tomography (PET/CT), clinicians cannot solely rely on F-18 Fluorodeoxyglucose (F-18 FDG) as there were few studies demonstrated the use of F-18 FDG was pointless in prostate cancer imaging. Thus, this current study presents development of convenient quality control analysis method and improvement performed on the azeotropic drying of no-carrier-added (n.c.a.) F-18 Fluorine to increase the F-18 Fluorocholine (F-18 FCH) radiochemical yield. From these studies, a convenient, efficient and reliable method for quality control analysis of F-18 FCH was successfully developed and validated to comply all the release criteria even in a limited equipment set-up. As most of the equipment set-up in the quality control laboratory in the present study was meant for the routine quality control analysis of F-18 FDG, several parameters were changed in order to adapt to the F-18 FCH quality control method without affecting the routine quality control analysis of F-18 FDG. The synthesis of F-18 FCH was successfully performed on a commercial synthesis module, GE TracerLab MxFDG with fairly good radiochemical yields, between 5 to 15%, which decay is not corrected. Interestingly, the finding from this study shows the potential of improvement on the azeotropic drying condition of n.c.a F-18 Fluorine as a preferred technique to improve the radiochemical yield of F-18 FCH. 2016-09 Thesis NonPeerReviewed text en http://psasir.upm.edu.my/id/eprint/75302/1/FPSK%28M%29%202016%2027%20IR.pdf Hassan, Muhammad Hishar (2016) Development of convenient quality control analysis method and improvement on the radiochemical yield using F-18-Labelled choline. Masters thesis, Universiti Putra Malaysia.
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Prostate cancer continues to be the most prevalent cancer in men in Malaysia. It is anticipated that the number of prostate cancer sufferers’ will increase in future. In the case of Positron Emission Tomography / Computed Tomography (PET/CT), clinicians cannot solely rely on F-18 Fluorodeoxyglucose (F-18 FDG) as there were few studies demonstrated the use of F-18 FDG was pointless in prostate cancer imaging. Thus, this current study presents development of convenient quality control analysis method and improvement performed on the azeotropic drying of no-carrier-added (n.c.a.) F-18 Fluorine to increase the F-18 Fluorocholine (F-18 FCH) radiochemical yield. From these studies, a convenient, efficient and reliable method for quality control analysis of F-18 FCH was successfully developed and validated to comply all the release criteria even in a limited equipment set-up. As most of the equipment set-up in the quality control laboratory in the present study was meant for the routine quality control analysis of F-18 FDG, several parameters were changed in order to adapt to the F-18 FCH quality control method without affecting the routine quality control analysis of F-18 FDG. The synthesis of F-18 FCH was successfully performed on a commercial synthesis module, GE TracerLab MxFDG with fairly good radiochemical yields, between 5 to 15%, which decay is not corrected. Interestingly, the finding from this study shows the potential of improvement on the azeotropic drying condition of n.c.a F-18 Fluorine as a preferred technique to improve the radiochemical yield of F-18 FCH.
format Thesis
author Hassan, Muhammad Hishar
spellingShingle Hassan, Muhammad Hishar
Development of convenient quality control analysis method and improvement on the radiochemical yield using F-18-Labelled choline
author_facet Hassan, Muhammad Hishar
author_sort Hassan, Muhammad Hishar
title Development of convenient quality control analysis method and improvement on the radiochemical yield using F-18-Labelled choline
title_short Development of convenient quality control analysis method and improvement on the radiochemical yield using F-18-Labelled choline
title_full Development of convenient quality control analysis method and improvement on the radiochemical yield using F-18-Labelled choline
title_fullStr Development of convenient quality control analysis method and improvement on the radiochemical yield using F-18-Labelled choline
title_full_unstemmed Development of convenient quality control analysis method and improvement on the radiochemical yield using F-18-Labelled choline
title_sort development of convenient quality control analysis method and improvement on the radiochemical yield using f-18-labelled choline
publishDate 2016
url http://psasir.upm.edu.my/id/eprint/75302/1/FPSK%28M%29%202016%2027%20IR.pdf
http://psasir.upm.edu.my/id/eprint/75302/
_version_ 1648738194895667200
score 13.211869