Computational fluid dynamic analysis on microvascular vein grafting: effect of mismatched conduit diameters

An artery disease of upper extremity is uncommon happened. The most common cause of artery disease in upper extremity is atherosclerosis. In few patients with artery disease, surgical vein bypassing or vein interposition is frequently performed. However, one or more the internal diameters of applied...

Full description

Saved in:
Bibliographic Details
Main Authors: Yahya, Muhd Nur Rahman, Abu Bakar, Shahriman, Za'aba, Siti Khadijah, Syed Waseem Ahmad, Sharifah Roohi, Wan Ahmad, Wan Khairunizam, Ismail, Abdul Halim
Format: Conference or Workshop Item
Language:English
Published: IEEE 2012
Online Access:http://psasir.upm.edu.my/id/eprint/68192/1/Computational%20fluid%20dynamic%20analysis%20on%20microvascular%20vein%20grafting%20effect%20of%20mismatched%20conduit%20diameters.pdf
http://psasir.upm.edu.my/id/eprint/68192/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.68192
record_format eprints
spelling my.upm.eprints.681922019-05-09T03:38:35Z http://psasir.upm.edu.my/id/eprint/68192/ Computational fluid dynamic analysis on microvascular vein grafting: effect of mismatched conduit diameters Yahya, Muhd Nur Rahman Abu Bakar, Shahriman Za'aba, Siti Khadijah Syed Waseem Ahmad, Sharifah Roohi Wan Ahmad, Wan Khairunizam Ismail, Abdul Halim An artery disease of upper extremity is uncommon happened. The most common cause of artery disease in upper extremity is atherosclerosis. In few patients with artery disease, surgical vein bypassing or vein interposition is frequently performed. However, one or more the internal diameters of applied vein graft are blocked or severely norrowed due to the mismatched diameter between existing artery and vein graft. The objective of this study is to investigate the blood flow influence on vein graft with mismatched diameter failure. The 3-D computational fluid dynamic method was employed to determine pulsatile flow velocity, pulsatile pressure gradient, and wall shear stress impact on the mismatched diameter of artery-vein graft model. We expect that pulsatile flow velocity, pulsatile pressure gradient, and wall shear stress impact on mismatched diameter of artery-vein graft model to behave non-hydraulically compared to an ideal matched model. IEEE 2012 Conference or Workshop Item PeerReviewed text en http://psasir.upm.edu.my/id/eprint/68192/1/Computational%20fluid%20dynamic%20analysis%20on%20microvascular%20vein%20grafting%20effect%20of%20mismatched%20conduit%20diameters.pdf Yahya, Muhd Nur Rahman and Abu Bakar, Shahriman and Za'aba, Siti Khadijah and Syed Waseem Ahmad, Sharifah Roohi and Wan Ahmad, Wan Khairunizam and Ismail, Abdul Halim (2012) Computational fluid dynamic analysis on microvascular vein grafting: effect of mismatched conduit diameters. In: 2012 IEEE-EMBS Conference on Biomedical Engineering and Sciences (IECBES 2012), 17-19 Dec. 2012, Langkawi, Kedah, Malaysia. (pp. 583-588). 10.1109/IECBES.2012.6498087
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description An artery disease of upper extremity is uncommon happened. The most common cause of artery disease in upper extremity is atherosclerosis. In few patients with artery disease, surgical vein bypassing or vein interposition is frequently performed. However, one or more the internal diameters of applied vein graft are blocked or severely norrowed due to the mismatched diameter between existing artery and vein graft. The objective of this study is to investigate the blood flow influence on vein graft with mismatched diameter failure. The 3-D computational fluid dynamic method was employed to determine pulsatile flow velocity, pulsatile pressure gradient, and wall shear stress impact on the mismatched diameter of artery-vein graft model. We expect that pulsatile flow velocity, pulsatile pressure gradient, and wall shear stress impact on mismatched diameter of artery-vein graft model to behave non-hydraulically compared to an ideal matched model.
format Conference or Workshop Item
author Yahya, Muhd Nur Rahman
Abu Bakar, Shahriman
Za'aba, Siti Khadijah
Syed Waseem Ahmad, Sharifah Roohi
Wan Ahmad, Wan Khairunizam
Ismail, Abdul Halim
spellingShingle Yahya, Muhd Nur Rahman
Abu Bakar, Shahriman
Za'aba, Siti Khadijah
Syed Waseem Ahmad, Sharifah Roohi
Wan Ahmad, Wan Khairunizam
Ismail, Abdul Halim
Computational fluid dynamic analysis on microvascular vein grafting: effect of mismatched conduit diameters
author_facet Yahya, Muhd Nur Rahman
Abu Bakar, Shahriman
Za'aba, Siti Khadijah
Syed Waseem Ahmad, Sharifah Roohi
Wan Ahmad, Wan Khairunizam
Ismail, Abdul Halim
author_sort Yahya, Muhd Nur Rahman
title Computational fluid dynamic analysis on microvascular vein grafting: effect of mismatched conduit diameters
title_short Computational fluid dynamic analysis on microvascular vein grafting: effect of mismatched conduit diameters
title_full Computational fluid dynamic analysis on microvascular vein grafting: effect of mismatched conduit diameters
title_fullStr Computational fluid dynamic analysis on microvascular vein grafting: effect of mismatched conduit diameters
title_full_unstemmed Computational fluid dynamic analysis on microvascular vein grafting: effect of mismatched conduit diameters
title_sort computational fluid dynamic analysis on microvascular vein grafting: effect of mismatched conduit diameters
publisher IEEE
publishDate 2012
url http://psasir.upm.edu.my/id/eprint/68192/1/Computational%20fluid%20dynamic%20analysis%20on%20microvascular%20vein%20grafting%20effect%20of%20mismatched%20conduit%20diameters.pdf
http://psasir.upm.edu.my/id/eprint/68192/
_version_ 1643839128414978048
score 13.211869