Review of surface electrode placement for recording electromyography signals

Background: Surface Electromyography (SEMG) signal has used in monitoring muscle activities. It has been widely applied in many areas, such as body member prosthesis, noise cancellation for brain-computer interface, and robotics. The SEMG acquisition method for collecting the signal with low-noise...

Full description

Saved in:
Bibliographic Details
Main Authors: Ghapanchizadeh, Hossein, Ahmad, Siti Aqlima, Ishak, Asnor Juraiza, Al-quraishi, Maged Saleh Saeed
Format: Article
Language:English
Published: Allied Academies 2016
Online Access:http://psasir.upm.edu.my/id/eprint/62986/1/Review%20of%20surface%20electrode%20placement%20for%20recording%20electromyography%20signals.pdf
http://psasir.upm.edu.my/id/eprint/62986/
https://pdfs.semanticscholar.org/67cd/c26eacd0b84453ddc9984092c52b2d490e7c.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.62986
record_format eprints
spelling my.upm.eprints.629862018-09-28T10:26:42Z http://psasir.upm.edu.my/id/eprint/62986/ Review of surface electrode placement for recording electromyography signals Ghapanchizadeh, Hossein Ahmad, Siti Aqlima Ishak, Asnor Juraiza Al-quraishi, Maged Saleh Saeed Background: Surface Electromyography (SEMG) signal has used in monitoring muscle activities. It has been widely applied in many areas, such as body member prosthesis, noise cancellation for brain-computer interface, and robotics. The SEMG acquisition method for collecting the signal with low-noise has extensively investigated in the last decade. The objective of this study is to review the recent works on electrode position and identify avenues for future research. Methods: A review of the relevant literature published between 1986 and 2015. This study commences with the basics of SEMG and recent methods for electrode position. Result: The different noises affecting SEMG signal include the spread of the innervation zone, cross-talk from neighbour muscles, electrode size, and location of electrode placement. Moreover, electrode placement or displacement effect SEMG signal in both time and frequency domain. Conclusion: Although several SEMG studies examined the effects of electrode position and internal electrode distance on forearm muscles, only a few studies addressed the methodological difficulties of the electrode position. In the majority of studies, electrodes were placed without the specific symptoms of the points along the length or shape of the muscle. Moreover, IED varied in different studies. Allied Academies 2016-07-13 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/62986/1/Review%20of%20surface%20electrode%20placement%20for%20recording%20electromyography%20signals.pdf Ghapanchizadeh, Hossein and Ahmad, Siti Aqlima and Ishak, Asnor Juraiza and Al-quraishi, Maged Saleh Saeed (2016) Review of surface electrode placement for recording electromyography signals. Biomedical Research, 2017. S1-S7. ISSN 0970-938X; ESSN: 0976-1683 https://pdfs.semanticscholar.org/67cd/c26eacd0b84453ddc9984092c52b2d490e7c.pdf
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Background: Surface Electromyography (SEMG) signal has used in monitoring muscle activities. It has been widely applied in many areas, such as body member prosthesis, noise cancellation for brain-computer interface, and robotics. The SEMG acquisition method for collecting the signal with low-noise has extensively investigated in the last decade. The objective of this study is to review the recent works on electrode position and identify avenues for future research. Methods: A review of the relevant literature published between 1986 and 2015. This study commences with the basics of SEMG and recent methods for electrode position. Result: The different noises affecting SEMG signal include the spread of the innervation zone, cross-talk from neighbour muscles, electrode size, and location of electrode placement. Moreover, electrode placement or displacement effect SEMG signal in both time and frequency domain. Conclusion: Although several SEMG studies examined the effects of electrode position and internal electrode distance on forearm muscles, only a few studies addressed the methodological difficulties of the electrode position. In the majority of studies, electrodes were placed without the specific symptoms of the points along the length or shape of the muscle. Moreover, IED varied in different studies.
format Article
author Ghapanchizadeh, Hossein
Ahmad, Siti Aqlima
Ishak, Asnor Juraiza
Al-quraishi, Maged Saleh Saeed
spellingShingle Ghapanchizadeh, Hossein
Ahmad, Siti Aqlima
Ishak, Asnor Juraiza
Al-quraishi, Maged Saleh Saeed
Review of surface electrode placement for recording electromyography signals
author_facet Ghapanchizadeh, Hossein
Ahmad, Siti Aqlima
Ishak, Asnor Juraiza
Al-quraishi, Maged Saleh Saeed
author_sort Ghapanchizadeh, Hossein
title Review of surface electrode placement for recording electromyography signals
title_short Review of surface electrode placement for recording electromyography signals
title_full Review of surface electrode placement for recording electromyography signals
title_fullStr Review of surface electrode placement for recording electromyography signals
title_full_unstemmed Review of surface electrode placement for recording electromyography signals
title_sort review of surface electrode placement for recording electromyography signals
publisher Allied Academies
publishDate 2016
url http://psasir.upm.edu.my/id/eprint/62986/1/Review%20of%20surface%20electrode%20placement%20for%20recording%20electromyography%20signals.pdf
http://psasir.upm.edu.my/id/eprint/62986/
https://pdfs.semanticscholar.org/67cd/c26eacd0b84453ddc9984092c52b2d490e7c.pdf
_version_ 1643837725259857920
score 13.211869