Determining the ultrasound time of response using FPGA-based electronics read-out
This paper presents a system to measure accurate value of time of response (TOR) for ultrasound transducer pairs based on Field Programmable Gate Arrays (FPGA). In the experiment, the transmitter is set to transmit the pulse to the target object and the reflected signal is then captured by the recei...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
IEEE
2016
|
Online Access: | http://psasir.upm.edu.my/id/eprint/55939/1/Determining%20the%20ultrasound%20time%20of%20response%20using%20FPGA-based%20electronics%20read-out.pdf http://psasir.upm.edu.my/id/eprint/55939/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.upm.eprints.55939 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.559392017-06-30T09:55:04Z http://psasir.upm.edu.my/id/eprint/55939/ Determining the ultrasound time of response using FPGA-based electronics read-out Ahmad, Norhayati Saripan, M. Iqbal Marhaban, Mohammad Hamiruce Rokhani, Fakhrul Zaman Mohd Saad, Wira Hidayat This paper presents a system to measure accurate value of time of response (TOR) for ultrasound transducer pairs based on Field Programmable Gate Arrays (FPGA). In the experiment, the transmitter is set to transmit the pulse to the target object and the reflected signal is then captured by the receiver. The time taken for the signal to travel back to the receiver is measured by TOR. FPGA technology and data acquisition system were used to generate a pulse at the transmitter site. The pulse is projected directly to the targeted object and the signal that has been reflected from the object will be captured three times by the receiver. The results show that the TOR value obtained can be calculated accurately. The best TOR found in this study is the signal capture 1 with the lowest percentage error of 0.819%. IEEE 2016 Conference or Workshop Item PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/55939/1/Determining%20the%20ultrasound%20time%20of%20response%20using%20FPGA-based%20electronics%20read-out.pdf Ahmad, Norhayati and Saripan, M. Iqbal and Marhaban, Mohammad Hamiruce and Rokhani, Fakhrul Zaman and Mohd Saad, Wira Hidayat (2016) Determining the ultrasound time of response using FPGA-based electronics read-out. In: 2016 IEEE-EMBS Conference on Biomedical Engineering and Sciences (IECBES), 4-8 Dec. 2016, Kuala Lumpur, Malaysia. (pp. 769-773). 10.1109/IECBES.2016.7843554 |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
This paper presents a system to measure accurate value of time of response (TOR) for ultrasound transducer pairs based on Field Programmable Gate Arrays (FPGA). In the experiment, the transmitter is set to transmit the pulse to the target object and the reflected signal is then captured by the receiver. The time taken for the signal to travel back to the receiver is measured by TOR. FPGA technology and data acquisition system were used to generate a pulse at the transmitter site. The pulse is projected directly to the targeted object and the signal that has been reflected from the object will be captured three times by the receiver. The results show that the TOR value obtained can be calculated accurately. The best TOR found in this study is the signal capture 1 with the lowest percentage error of 0.819%. |
format |
Conference or Workshop Item |
author |
Ahmad, Norhayati Saripan, M. Iqbal Marhaban, Mohammad Hamiruce Rokhani, Fakhrul Zaman Mohd Saad, Wira Hidayat |
spellingShingle |
Ahmad, Norhayati Saripan, M. Iqbal Marhaban, Mohammad Hamiruce Rokhani, Fakhrul Zaman Mohd Saad, Wira Hidayat Determining the ultrasound time of response using FPGA-based electronics read-out |
author_facet |
Ahmad, Norhayati Saripan, M. Iqbal Marhaban, Mohammad Hamiruce Rokhani, Fakhrul Zaman Mohd Saad, Wira Hidayat |
author_sort |
Ahmad, Norhayati |
title |
Determining the ultrasound time of response using FPGA-based electronics read-out |
title_short |
Determining the ultrasound time of response using FPGA-based electronics read-out |
title_full |
Determining the ultrasound time of response using FPGA-based electronics read-out |
title_fullStr |
Determining the ultrasound time of response using FPGA-based electronics read-out |
title_full_unstemmed |
Determining the ultrasound time of response using FPGA-based electronics read-out |
title_sort |
determining the ultrasound time of response using fpga-based electronics read-out |
publisher |
IEEE |
publishDate |
2016 |
url |
http://psasir.upm.edu.my/id/eprint/55939/1/Determining%20the%20ultrasound%20time%20of%20response%20using%20FPGA-based%20electronics%20read-out.pdf http://psasir.upm.edu.my/id/eprint/55939/ |
_version_ |
1643836042646650880 |
score |
13.211869 |