Experimental and numerical study of stenotic flows

Atherosclerosis has been leading cause of deaths in several countries. Recent technical advances have allowed the investigation of stenotic flows and in understanding the implications with increased severity. Such studies shall provide detailed understanding of flow across stenosis and its progressi...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdul Khader, Shah Mohammed, Adathala, Rajeev, Ayachit, Anurag, Pai, Raghuvir, Vayalappil, Muraleedharan C., Zuber, Mohammad, Rao, V. R. K.
Format: Article
Language:English
Published: American Scientific Publishers 2016
Online Access:http://psasir.upm.edu.my/id/eprint/54231/1/Experimental%20and%20numerical%20study%20of%20stenotic%20flows%20.pdf
http://psasir.upm.edu.my/id/eprint/54231/
http://www.ingentaconnect.com/content/asp/jmihi/2016/00000006/00000006/art00025
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.54231
record_format eprints
spelling my.upm.eprints.542312018-03-08T02:35:50Z http://psasir.upm.edu.my/id/eprint/54231/ Experimental and numerical study of stenotic flows Abdul Khader, Shah Mohammed Adathala, Rajeev Ayachit, Anurag Pai, Raghuvir Vayalappil, Muraleedharan C. Zuber, Mohammad Rao, V. R. K. Atherosclerosis has been leading cause of deaths in several countries. Recent technical advances have allowed the investigation of stenotic flows and in understanding the implications with increased severity. Such studies shall provide detailed understanding of flow across stenosis and its progression. In the present study, a large artery representing segment of aorta is considered as test specimen. Experimental study is carried out by generating the pulsatile flow through pulsatile duplicator. Flow across normal and various severities of stenosis such as 25%, 50% and 75% are studied. Numerical simulation using CFD is also carried out in similar normal and stenosed models. A novel concept of using pulse duplicator to generate pulsatile waves and investigate the different stenosed models has been adopted. Results obtained experimentally and numerically are compared and agree well with that of clinical observations. This study demonstrates significant variation of haemodynamic in post-stenotic region with increased stenosis. Increased pulse pressure, phase lag is observed with increased severity. It is also observed that stenosis greater than 75% is significant as flow complexity is induced with considerable disturbance even in early and latter part of pulse cycle. Such study shall be useful in understanding the flow changes in stenosis and enhance clinical observation. American Scientific Publishers 2016-10 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/54231/1/Experimental%20and%20numerical%20study%20of%20stenotic%20flows%20.pdf Abdul Khader, Shah Mohammed and Adathala, Rajeev and Ayachit, Anurag and Pai, Raghuvir and Vayalappil, Muraleedharan C. and Zuber, Mohammad and Rao, V. R. K. (2016) Experimental and numerical study of stenotic flows. Journal of Medical Imaging and Health Informatics, 6 (6). pp. 1500-1506. ISSN 2156-7018; ESSN: 2156-7026 http://www.ingentaconnect.com/content/asp/jmihi/2016/00000006/00000006/art00025 10.1166/jmihi.2016.1838
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Atherosclerosis has been leading cause of deaths in several countries. Recent technical advances have allowed the investigation of stenotic flows and in understanding the implications with increased severity. Such studies shall provide detailed understanding of flow across stenosis and its progression. In the present study, a large artery representing segment of aorta is considered as test specimen. Experimental study is carried out by generating the pulsatile flow through pulsatile duplicator. Flow across normal and various severities of stenosis such as 25%, 50% and 75% are studied. Numerical simulation using CFD is also carried out in similar normal and stenosed models. A novel concept of using pulse duplicator to generate pulsatile waves and investigate the different stenosed models has been adopted. Results obtained experimentally and numerically are compared and agree well with that of clinical observations. This study demonstrates significant variation of haemodynamic in post-stenotic region with increased stenosis. Increased pulse pressure, phase lag is observed with increased severity. It is also observed that stenosis greater than 75% is significant as flow complexity is induced with considerable disturbance even in early and latter part of pulse cycle. Such study shall be useful in understanding the flow changes in stenosis and enhance clinical observation.
format Article
author Abdul Khader, Shah Mohammed
Adathala, Rajeev
Ayachit, Anurag
Pai, Raghuvir
Vayalappil, Muraleedharan C.
Zuber, Mohammad
Rao, V. R. K.
spellingShingle Abdul Khader, Shah Mohammed
Adathala, Rajeev
Ayachit, Anurag
Pai, Raghuvir
Vayalappil, Muraleedharan C.
Zuber, Mohammad
Rao, V. R. K.
Experimental and numerical study of stenotic flows
author_facet Abdul Khader, Shah Mohammed
Adathala, Rajeev
Ayachit, Anurag
Pai, Raghuvir
Vayalappil, Muraleedharan C.
Zuber, Mohammad
Rao, V. R. K.
author_sort Abdul Khader, Shah Mohammed
title Experimental and numerical study of stenotic flows
title_short Experimental and numerical study of stenotic flows
title_full Experimental and numerical study of stenotic flows
title_fullStr Experimental and numerical study of stenotic flows
title_full_unstemmed Experimental and numerical study of stenotic flows
title_sort experimental and numerical study of stenotic flows
publisher American Scientific Publishers
publishDate 2016
url http://psasir.upm.edu.my/id/eprint/54231/1/Experimental%20and%20numerical%20study%20of%20stenotic%20flows%20.pdf
http://psasir.upm.edu.my/id/eprint/54231/
http://www.ingentaconnect.com/content/asp/jmihi/2016/00000006/00000006/art00025
_version_ 1643835593943154688
score 13.211869