Correlation of furfural and moisture content with age of transformers

This paper is aimed at analysis of correlation between age of 132/33kV and 33/11kV transformers with furfural concentration and carbon oxides content of oil. Also, the correlation of moisture content and relative humidity of oil/paper insulation system with furfural concentration of oil is investiga...

Full description

Saved in:
Bibliographic Details
Main Authors: Aminian, Masoud, Ab Kadir, Mohd Zainal Abidin, Ali, Salmiaton, Wan Ahmad, Wan Fatinhamamah, Ishak, Mohd Taufiq, Izadi, Mahdi
Format: Conference or Workshop Item
Language:English
Published: IEEE 2013
Online Access:http://psasir.upm.edu.my/id/eprint/47752/1/Correlation%20of%20furfural%20and%20moisture%20content%20with%20age%20of%20transformers.pdf
http://psasir.upm.edu.my/id/eprint/47752/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.47752
record_format eprints
spelling my.upm.eprints.477522016-07-14T09:38:44Z http://psasir.upm.edu.my/id/eprint/47752/ Correlation of furfural and moisture content with age of transformers Aminian, Masoud Ab Kadir, Mohd Zainal Abidin Ali, Salmiaton Wan Ahmad, Wan Fatinhamamah Ishak, Mohd Taufiq Izadi, Mahdi This paper is aimed at analysis of correlation between age of 132/33kV and 33/11kV transformers with furfural concentration and carbon oxides content of oil. Also, the correlation of moisture content and relative humidity of oil/paper insulation system with furfural concentration of oil is investigated. The secondary data was obtained from the raw data of research studies which have been done in Malaysia on inservice power transformers. As a result, it is not only confirmed that furfural content in the oil was increased by increasing moisture content of the oil, but also there is a good correlation and significant relationship between furfural concentration of the oil and relative humidity of oil/paper insulation system. Also, descriptive statistics such as mean, standard deviation and normal distribution of furfural and moisture content per year of service of transformers described the level of evolution of moisture and furfural for these transformers at normal temperature. IEEE 2013 Conference or Workshop Item PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/47752/1/Correlation%20of%20furfural%20and%20moisture%20content%20with%20age%20of%20transformers.pdf Aminian, Masoud and Ab Kadir, Mohd Zainal Abidin and Ali, Salmiaton and Wan Ahmad, Wan Fatinhamamah and Ishak, Mohd Taufiq and Izadi, Mahdi (2013) Correlation of furfural and moisture content with age of transformers. In: 2013 IEEE 7th International Power Engineering and Optimization Conference (PEOCO 2013), 3-4 June 2013, Langkawi, Kedah. (pp. 366-368). 10.1109/PEOCO.2013.6564574
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description This paper is aimed at analysis of correlation between age of 132/33kV and 33/11kV transformers with furfural concentration and carbon oxides content of oil. Also, the correlation of moisture content and relative humidity of oil/paper insulation system with furfural concentration of oil is investigated. The secondary data was obtained from the raw data of research studies which have been done in Malaysia on inservice power transformers. As a result, it is not only confirmed that furfural content in the oil was increased by increasing moisture content of the oil, but also there is a good correlation and significant relationship between furfural concentration of the oil and relative humidity of oil/paper insulation system. Also, descriptive statistics such as mean, standard deviation and normal distribution of furfural and moisture content per year of service of transformers described the level of evolution of moisture and furfural for these transformers at normal temperature.
format Conference or Workshop Item
author Aminian, Masoud
Ab Kadir, Mohd Zainal Abidin
Ali, Salmiaton
Wan Ahmad, Wan Fatinhamamah
Ishak, Mohd Taufiq
Izadi, Mahdi
spellingShingle Aminian, Masoud
Ab Kadir, Mohd Zainal Abidin
Ali, Salmiaton
Wan Ahmad, Wan Fatinhamamah
Ishak, Mohd Taufiq
Izadi, Mahdi
Correlation of furfural and moisture content with age of transformers
author_facet Aminian, Masoud
Ab Kadir, Mohd Zainal Abidin
Ali, Salmiaton
Wan Ahmad, Wan Fatinhamamah
Ishak, Mohd Taufiq
Izadi, Mahdi
author_sort Aminian, Masoud
title Correlation of furfural and moisture content with age of transformers
title_short Correlation of furfural and moisture content with age of transformers
title_full Correlation of furfural and moisture content with age of transformers
title_fullStr Correlation of furfural and moisture content with age of transformers
title_full_unstemmed Correlation of furfural and moisture content with age of transformers
title_sort correlation of furfural and moisture content with age of transformers
publisher IEEE
publishDate 2013
url http://psasir.upm.edu.my/id/eprint/47752/1/Correlation%20of%20furfural%20and%20moisture%20content%20with%20age%20of%20transformers.pdf
http://psasir.upm.edu.my/id/eprint/47752/
_version_ 1643833972273184768
score 13.211869