Preliminary results from attenuation correction for MCNP-generated PET image
This paper presents the preliminary results of PET system simulation using Monte Carlo code. We also present the implementation of attenuation correction for MCNP-generated PET image. Using MCNP5 we constructed a data base for a uniform cylindrical source. The data obtained from the simulation were...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
IEEE
2012
|
Online Access: | http://psasir.upm.edu.my/id/eprint/41243/1/Preliminary%20results%20from%20attenuation%20correction%20for%20MCNP-generated%20PET%20image.pdf http://psasir.upm.edu.my/id/eprint/41243/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.upm.eprints.41243 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.412432018-10-26T07:04:46Z http://psasir.upm.edu.my/id/eprint/41243/ Preliminary results from attenuation correction for MCNP-generated PET image Musarudin, Marianie Saripan, M. Iqbal Mashohor, Syamsiah Mohd Saad, Wira Hidayat Hashim, Suhairul Nordin, Abdul Jalil This paper presents the preliminary results of PET system simulation using Monte Carlo code. We also present the implementation of attenuation correction for MCNP-generated PET image. Using MCNP5 we constructed a data base for a uniform cylindrical source. The data obtained from the simulation were then used for PET image reconstruction. During the image reconstruction, calculated attenuation correction method was implemented to the PET raw data. This method was chosen due to the fact that our study involved homogeneous and simple geometry phantom. IEEE 2012 Conference or Workshop Item PeerReviewed text en http://psasir.upm.edu.my/id/eprint/41243/1/Preliminary%20results%20from%20attenuation%20correction%20for%20MCNP-generated%20PET%20image.pdf Musarudin, Marianie and Saripan, M. Iqbal and Mashohor, Syamsiah and Mohd Saad, Wira Hidayat and Hashim, Suhairul and Nordin, Abdul Jalil (2012) Preliminary results from attenuation correction for MCNP-generated PET image. In: 2012 IEEE-EMBS Conference on Biomedical Engineering and Sciences (IECBES 2012), 17-19 Dec. 2012, Langkawi, Kedah, Malaysia. (pp. 907-910). 10.1109/IECBES.2012.6498037 |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
This paper presents the preliminary results of PET system simulation using Monte Carlo code. We also present the implementation of attenuation correction for MCNP-generated PET image. Using MCNP5 we constructed a data base for a uniform cylindrical source. The data obtained from the simulation were then used for PET image reconstruction. During the image reconstruction, calculated attenuation correction method was implemented to the PET raw data. This method was chosen due to the fact that our study involved homogeneous and simple geometry phantom. |
format |
Conference or Workshop Item |
author |
Musarudin, Marianie Saripan, M. Iqbal Mashohor, Syamsiah Mohd Saad, Wira Hidayat Hashim, Suhairul Nordin, Abdul Jalil |
spellingShingle |
Musarudin, Marianie Saripan, M. Iqbal Mashohor, Syamsiah Mohd Saad, Wira Hidayat Hashim, Suhairul Nordin, Abdul Jalil Preliminary results from attenuation correction for MCNP-generated PET image |
author_facet |
Musarudin, Marianie Saripan, M. Iqbal Mashohor, Syamsiah Mohd Saad, Wira Hidayat Hashim, Suhairul Nordin, Abdul Jalil |
author_sort |
Musarudin, Marianie |
title |
Preliminary results from attenuation correction for MCNP-generated PET image |
title_short |
Preliminary results from attenuation correction for MCNP-generated PET image |
title_full |
Preliminary results from attenuation correction for MCNP-generated PET image |
title_fullStr |
Preliminary results from attenuation correction for MCNP-generated PET image |
title_full_unstemmed |
Preliminary results from attenuation correction for MCNP-generated PET image |
title_sort |
preliminary results from attenuation correction for mcnp-generated pet image |
publisher |
IEEE |
publishDate |
2012 |
url |
http://psasir.upm.edu.my/id/eprint/41243/1/Preliminary%20results%20from%20attenuation%20correction%20for%20MCNP-generated%20PET%20image.pdf http://psasir.upm.edu.my/id/eprint/41243/ |
_version_ |
1643832942135345152 |
score |
13.211869 |