CFD analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies

Most of the industrial chemical products encounter natural environmental risk in the process. The indoor release of hazardous dense gases is especial topic for discussion nowadays because the clouds of heavier gases have a tendency to stay near the ground level, causing fatal and injuries the people...

Full description

Saved in:
Bibliographic Details
Main Authors: Safakar, Masiha, Syam, Syafiie, Yunus, Robiah
Format: Conference or Workshop Item
Language:English
Published: IEEE 2014
Online Access:http://psasir.upm.edu.my/id/eprint/39917/1/CFD%20analysis%20chlorine%20gas%20dispersion%20in%20indoor%20storage%20temperatures%20with%20wind%20velocities%20effect%20studies.pdf
http://psasir.upm.edu.my/id/eprint/39917/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.39917
record_format eprints
spelling my.upm.eprints.399172017-06-06T09:15:35Z http://psasir.upm.edu.my/id/eprint/39917/ CFD analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies Safakar, Masiha Syam, Syafiie Yunus, Robiah Most of the industrial chemical products encounter natural environmental risk in the process. The indoor release of hazardous dense gases is especial topic for discussion nowadays because the clouds of heavier gases have a tendency to stay near the ground level, causing fatal and injuries the people. In this article a computational fluid dynamics (CFD) code FLUENT was employed in order to model the accidental indoor dispersion of chlorine from a small undetected leak in an indoor industrial space. The results of simulation represented that the chlorine gas spread would behave like liquid and flows on the floor, also the concentration of chlorine increased to above the ground level slowly. The effects of various temperatures and wind velocities on dispersion of heavier gas will help to better identify the potential risks. In this paper, the effects of the environmental situations with the release and spread of chlorine in the indoor space were meticulously examined. IEEE 2014 Conference or Workshop Item NonPeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/39917/1/CFD%20analysis%20chlorine%20gas%20dispersion%20in%20indoor%20storage%20temperatures%20with%20wind%20velocities%20effect%20studies.pdf Safakar, Masiha and Syam, Syafiie and Yunus, Robiah (2014) CFD analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies. In: 2014 IEEE International Conference on Industrial Engineering and Engineering Management (IEEM), 9-12 Dec. 2014, Bandar Sunway, Selangor, Malaysia. (pp. 1219-1222). 10.1109/IEEM.2014.7058832
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Most of the industrial chemical products encounter natural environmental risk in the process. The indoor release of hazardous dense gases is especial topic for discussion nowadays because the clouds of heavier gases have a tendency to stay near the ground level, causing fatal and injuries the people. In this article a computational fluid dynamics (CFD) code FLUENT was employed in order to model the accidental indoor dispersion of chlorine from a small undetected leak in an indoor industrial space. The results of simulation represented that the chlorine gas spread would behave like liquid and flows on the floor, also the concentration of chlorine increased to above the ground level slowly. The effects of various temperatures and wind velocities on dispersion of heavier gas will help to better identify the potential risks. In this paper, the effects of the environmental situations with the release and spread of chlorine in the indoor space were meticulously examined.
format Conference or Workshop Item
author Safakar, Masiha
Syam, Syafiie
Yunus, Robiah
spellingShingle Safakar, Masiha
Syam, Syafiie
Yunus, Robiah
CFD analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies
author_facet Safakar, Masiha
Syam, Syafiie
Yunus, Robiah
author_sort Safakar, Masiha
title CFD analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies
title_short CFD analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies
title_full CFD analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies
title_fullStr CFD analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies
title_full_unstemmed CFD analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies
title_sort cfd analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies
publisher IEEE
publishDate 2014
url http://psasir.upm.edu.my/id/eprint/39917/1/CFD%20analysis%20chlorine%20gas%20dispersion%20in%20indoor%20storage%20temperatures%20with%20wind%20velocities%20effect%20studies.pdf
http://psasir.upm.edu.my/id/eprint/39917/
_version_ 1643832562697633792
score 13.223943