Effects of Organic Load on Basic Geotechnical Properties of Compacted Sand-kaolinite Mixture
In the laboratory, four PVC sand-kaolinite mixture columns, each of 150 cm depth and 15 cm diameter, were fed with solutions of sodium acetate equivalent to 20,000 p.p.m., 30,000 p.p.m., 40,000 p.p.m., and 50,000 p.p.m. BOD (biochemical oxygen demand). Soil physical and chemical properties, such as...
Saved in:
Main Authors: | , |
---|---|
格式: | Article |
語言: | English English |
出版: |
Universiti Putra Malaysia Press
1995
|
在線閱讀: | http://psasir.upm.edu.my/id/eprint/3852/1/Effects_of_Organic_Load_on_Basic_Geotechnical_Properties_of.pdf http://psasir.upm.edu.my/id/eprint/3852/ |
標簽: |
添加標簽
沒有標簽, 成為第一個標記此記錄!
|
總結: | In the laboratory, four PVC sand-kaolinite mixture columns, each of 150 cm depth and 15 cm diameter, were fed with solutions of sodium acetate equivalent to 20,000 p.p.m., 30,000 p.p.m., 40,000 p.p.m., and 50,000 p.p.m. BOD (biochemical oxygen demand). Soil physical and chemical properties, such as Atterberg limits, specific gravity, soil pH and soil organic content, altered markedly within 40 days of continuous feeding. The results showed that feed