Calibration and accuracy determination of a microwave type sensor for measuring grain flow

Impact type grain flow sensor for crop yield monitoring is known to have problem of some thrown grain by the elevator conveyor in a combine not hitting the sensing impact plate. New technology of microwave solid flow sensor was used to solve the problem of impact-type sensor. A calibration stand wit...

Full description

Saved in:
Bibliographic Details
Main Authors: Renny Eka Putri,, Yahya, Azmi, Adam, Nor Mariah, Abd Aziz, Samsuzana, Ishola, Tajudeen Abiodun
Format: Article
Language:English
Published: Trans Tech Publications 2014
Online Access:http://psasir.upm.edu.my/id/eprint/36693/1/Calibration%20and%20accuracy%20determination%20of%20a%20microwave%20type%20sensor%20for%20measuring%20grain%20flow.pdf
http://psasir.upm.edu.my/id/eprint/36693/
http://www.scientific.net/AMR.931-932.1592
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.36693
record_format eprints
spelling my.upm.eprints.366932018-01-02T05:12:56Z http://psasir.upm.edu.my/id/eprint/36693/ Calibration and accuracy determination of a microwave type sensor for measuring grain flow Renny Eka Putri, Yahya, Azmi Adam, Nor Mariah Abd Aziz, Samsuzana Ishola, Tajudeen Abiodun Impact type grain flow sensor for crop yield monitoring is known to have problem of some thrown grain by the elevator conveyor in a combine not hitting the sensing impact plate. New technology of microwave solid flow sensor was used to solve the problem of impact-type sensor. A calibration stand with its instrumentation systems to stimulate the actual operation of the clean grain auger in a rice combine had been designed and constructed in this study for the purpose of conducting the calibration and evaluation study of the sensor. Two different solid flow sensor orientations and three different solid flow sensor extrusions were investigated in order to find the best positioning of the sensor on the chute for the measurement. Results from the conducted tests indicates that the best sensor positioning is on totally flat ground at 180o orientation and 8 cm extrusion of the chute cross section (R2=0.9400). Then, the solid flow sensor was tested at seven chute pitch angle positions (i.e-4.5o, -3.0o, -1.5o, 0o, +1.5o, + 3.0o, and +4.5 o), seven chute roll angle positions (i.e-4.5o,-3.0o, -1.5 o, 0o, +1.5o, +3.0 o, and +4.5o). Finally, accuracy tests undertaken to compare the real time measurements against the average flow measurements. ANOVA test shows that both pitch angle and roll angle positions have significant effects on the measurement accuracy of the sensor. The measurement errors increased with increasing roll angles and increasing pitch angle. Conclusively, this conducted laboratory study was able to quantify the measurement accuracy of the SWR Solid Flow sensor for real-time measurement of grain flow under a simulated laboratory rice combine test set-up. Trans Tech Publications 2014 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/36693/1/Calibration%20and%20accuracy%20determination%20of%20a%20microwave%20type%20sensor%20for%20measuring%20grain%20flow.pdf Renny Eka Putri, and Yahya, Azmi and Adam, Nor Mariah and Abd Aziz, Samsuzana and Ishola, Tajudeen Abiodun (2014) Calibration and accuracy determination of a microwave type sensor for measuring grain flow. Advanced Materials Research, 931-932. pp. 1592-1596. ISSN 1022-6680; ESSN: 1662-8985 http://www.scientific.net/AMR.931-932.1592 10.4028/www.scientific.net/AMR.931-932.1592
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Impact type grain flow sensor for crop yield monitoring is known to have problem of some thrown grain by the elevator conveyor in a combine not hitting the sensing impact plate. New technology of microwave solid flow sensor was used to solve the problem of impact-type sensor. A calibration stand with its instrumentation systems to stimulate the actual operation of the clean grain auger in a rice combine had been designed and constructed in this study for the purpose of conducting the calibration and evaluation study of the sensor. Two different solid flow sensor orientations and three different solid flow sensor extrusions were investigated in order to find the best positioning of the sensor on the chute for the measurement. Results from the conducted tests indicates that the best sensor positioning is on totally flat ground at 180o orientation and 8 cm extrusion of the chute cross section (R2=0.9400). Then, the solid flow sensor was tested at seven chute pitch angle positions (i.e-4.5o, -3.0o, -1.5o, 0o, +1.5o, + 3.0o, and +4.5 o), seven chute roll angle positions (i.e-4.5o,-3.0o, -1.5 o, 0o, +1.5o, +3.0 o, and +4.5o). Finally, accuracy tests undertaken to compare the real time measurements against the average flow measurements. ANOVA test shows that both pitch angle and roll angle positions have significant effects on the measurement accuracy of the sensor. The measurement errors increased with increasing roll angles and increasing pitch angle. Conclusively, this conducted laboratory study was able to quantify the measurement accuracy of the SWR Solid Flow sensor for real-time measurement of grain flow under a simulated laboratory rice combine test set-up.
format Article
author Renny Eka Putri,
Yahya, Azmi
Adam, Nor Mariah
Abd Aziz, Samsuzana
Ishola, Tajudeen Abiodun
spellingShingle Renny Eka Putri,
Yahya, Azmi
Adam, Nor Mariah
Abd Aziz, Samsuzana
Ishola, Tajudeen Abiodun
Calibration and accuracy determination of a microwave type sensor for measuring grain flow
author_facet Renny Eka Putri,
Yahya, Azmi
Adam, Nor Mariah
Abd Aziz, Samsuzana
Ishola, Tajudeen Abiodun
author_sort Renny Eka Putri,
title Calibration and accuracy determination of a microwave type sensor for measuring grain flow
title_short Calibration and accuracy determination of a microwave type sensor for measuring grain flow
title_full Calibration and accuracy determination of a microwave type sensor for measuring grain flow
title_fullStr Calibration and accuracy determination of a microwave type sensor for measuring grain flow
title_full_unstemmed Calibration and accuracy determination of a microwave type sensor for measuring grain flow
title_sort calibration and accuracy determination of a microwave type sensor for measuring grain flow
publisher Trans Tech Publications
publishDate 2014
url http://psasir.upm.edu.my/id/eprint/36693/1/Calibration%20and%20accuracy%20determination%20of%20a%20microwave%20type%20sensor%20for%20measuring%20grain%20flow.pdf
http://psasir.upm.edu.my/id/eprint/36693/
http://www.scientific.net/AMR.931-932.1592
_version_ 1643831807791071232
score 13.211869