Mechanical analysis of wearable lower limb exoskeleton for rehabilitation
This paper presents the mechanical analysis of a lower limb exoskeleton for rehabilitation for both legs that was developed in University Putra Malaysia (UPM). The main objective of the project is to develop a wearable exoskeleton system based on the average height of Malaysian to enhance...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Published: |
School of Engineering, Taylor’s University College
2014
|
Online Access: | http://psasir.upm.edu.my/id/eprint/34464/ http://jestec.taylors.edu.my/Special%20Issue%20SAES2013.htm |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.upm.eprints.34464 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.344642015-12-15T02:54:27Z http://psasir.upm.edu.my/id/eprint/34464/ Mechanical analysis of wearable lower limb exoskeleton for rehabilitation Wong, Zhen Yang Ishak, Asnor Juraiza Ahmad, Siti Anom Chong, Yu Zheng This paper presents the mechanical analysis of a lower limb exoskeleton for rehabilitation for both legs that was developed in University Putra Malaysia (UPM). The main objective of the project is to develop a wearable exoskeleton system based on the average height of Malaysian to enhance the wearability of the system to lower limbs. An anthropomorphic design was adopted in the prototype with pneumatic actuations at the knee with one (1) degree of freedom (DOF), and ankle joints with two (2) DOFs via McKibben Pneumatic Artificial Muscle (MPAM). The prototype also mimics normal human joints range of motion (ROM) to enable movements similar to normal human gait patterns. Such anthropomorphic prototype was designed to fit users with different heights for both genders (male: 1.6$1.8 m, female: 1.5$1.7 m). As a result, the frame can be adjusted from 0.37$0.42 m for thigh segment and 0.385$0.445 m for lower leg segment. The actuation properties of MPAM also determined as well as Vertical Ground Reaction Force (VGRF) analysis to be performed to determine the performance of the prototype once integrated with actuation system and control system. School of Engineering, Taylor’s University College 2014-10 Article PeerReviewed Wong, Zhen Yang and Ishak, Asnor Juraiza and Ahmad, Siti Anom and Chong, Yu Zheng (2014) Mechanical analysis of wearable lower limb exoskeleton for rehabilitation. Journal of Engineering Science and Technology, 9 (spec.). pp. 107-114. ISSN 1823-4690 http://jestec.taylors.edu.my/Special%20Issue%20SAES2013.htm |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
description |
This paper presents the mechanical analysis of a lower limb exoskeleton for rehabilitation for both legs that was developed in University Putra Malaysia (UPM). The main objective of the project is to develop a wearable exoskeleton system based on the average height of Malaysian to enhance the wearability of the system to lower limbs. An anthropomorphic design was adopted in the prototype with pneumatic actuations at the knee with one (1) degree of freedom (DOF), and ankle joints with two (2) DOFs via McKibben Pneumatic Artificial Muscle (MPAM). The prototype also mimics normal human joints range of motion (ROM) to enable movements similar to normal human gait patterns. Such anthropomorphic prototype was designed to fit users with different heights for both genders (male: 1.6$1.8 m, female: 1.5$1.7 m). As a result, the frame can be adjusted from 0.37$0.42 m for thigh segment and 0.385$0.445 m for lower leg segment. The actuation properties of MPAM also determined as well as Vertical Ground Reaction Force (VGRF) analysis to be performed to determine the performance of the prototype once integrated with actuation system and control system. |
format |
Article |
author |
Wong, Zhen Yang Ishak, Asnor Juraiza Ahmad, Siti Anom Chong, Yu Zheng |
spellingShingle |
Wong, Zhen Yang Ishak, Asnor Juraiza Ahmad, Siti Anom Chong, Yu Zheng Mechanical analysis of wearable lower limb exoskeleton for rehabilitation |
author_facet |
Wong, Zhen Yang Ishak, Asnor Juraiza Ahmad, Siti Anom Chong, Yu Zheng |
author_sort |
Wong, Zhen Yang |
title |
Mechanical analysis of wearable lower limb exoskeleton for rehabilitation |
title_short |
Mechanical analysis of wearable lower limb exoskeleton for rehabilitation |
title_full |
Mechanical analysis of wearable lower limb exoskeleton for rehabilitation |
title_fullStr |
Mechanical analysis of wearable lower limb exoskeleton for rehabilitation |
title_full_unstemmed |
Mechanical analysis of wearable lower limb exoskeleton for rehabilitation |
title_sort |
mechanical analysis of wearable lower limb exoskeleton for rehabilitation |
publisher |
School of Engineering, Taylor’s University College |
publishDate |
2014 |
url |
http://psasir.upm.edu.my/id/eprint/34464/ http://jestec.taylors.edu.my/Special%20Issue%20SAES2013.htm |
_version_ |
1643831162154516480 |
score |
13.211869 |