Calculation of the Effective Stopping Power of Ions Generated by Neutrons in Tissue Constituents

This paper reports the calculation of stopping powers of heavy charged particles generated by neutrons in four-element tissue constituents for particle energies from 0.1 keY to 1.0 MeV. At low projectile energies of less than 30 keV/amu where the nuclear stopping phenomenon is more dominant than t...

詳細記述

保存先:
書誌詳細
主要な著者: Saion, Elias, Watt, D. E.
フォーマット: 論文
言語:English
English
出版事項: 1992
オンライン・アクセス:http://psasir.upm.edu.my/id/eprint/2922/1/Calculation_of_the_Effective_Stopping_Power.pdf
http://psasir.upm.edu.my/id/eprint/2922/
タグ: タグ追加
タグなし, このレコードへの初めてのタグを付けませんか!
id my.upm.eprints.2922
record_format eprints
spelling my.upm.eprints.29222013-05-27T07:04:29Z http://psasir.upm.edu.my/id/eprint/2922/ Calculation of the Effective Stopping Power of Ions Generated by Neutrons in Tissue Constituents Saion, Elias Watt, D. E. This paper reports the calculation of stopping powers of heavy charged particles generated by neutrons in four-element tissue constituents for particle energies from 0.1 keY to 1.0 MeV. At low projectile energies of less than 30 keV/amu where the nuclear stopping phenomenon is more dominant than the electronic stopping phenomenon, the effective stopping power values are higher than the continuous slowing-down approximation (CSDA) values, from which the deviation is dependent upon the target mass and the energy and mass of the projectiles. 1992 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/2922/1/Calculation_of_the_Effective_Stopping_Power.pdf Saion, Elias and Watt, D. E. (1992) Calculation of the Effective Stopping Power of Ions Generated by Neutrons in Tissue Constituents. Pertanika, 15 (1). pp. 55-59. English
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
English
description This paper reports the calculation of stopping powers of heavy charged particles generated by neutrons in four-element tissue constituents for particle energies from 0.1 keY to 1.0 MeV. At low projectile energies of less than 30 keV/amu where the nuclear stopping phenomenon is more dominant than the electronic stopping phenomenon, the effective stopping power values are higher than the continuous slowing-down approximation (CSDA) values, from which the deviation is dependent upon the target mass and the energy and mass of the projectiles.
format Article
author Saion, Elias
Watt, D. E.
spellingShingle Saion, Elias
Watt, D. E.
Calculation of the Effective Stopping Power of Ions Generated by Neutrons in Tissue Constituents
author_facet Saion, Elias
Watt, D. E.
author_sort Saion, Elias
title Calculation of the Effective Stopping Power of Ions Generated by Neutrons in Tissue Constituents
title_short Calculation of the Effective Stopping Power of Ions Generated by Neutrons in Tissue Constituents
title_full Calculation of the Effective Stopping Power of Ions Generated by Neutrons in Tissue Constituents
title_fullStr Calculation of the Effective Stopping Power of Ions Generated by Neutrons in Tissue Constituents
title_full_unstemmed Calculation of the Effective Stopping Power of Ions Generated by Neutrons in Tissue Constituents
title_sort calculation of the effective stopping power of ions generated by neutrons in tissue constituents
publishDate 1992
url http://psasir.upm.edu.my/id/eprint/2922/1/Calculation_of_the_Effective_Stopping_Power.pdf
http://psasir.upm.edu.my/id/eprint/2922/
_version_ 1643822461251223552
score 13.251813