Electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode.
Electrochemical behaviour of paracetamol at the multi wall carbon nanotubes/titanium dioxide (MWCNT/TiO2) composite film modified glassy carbon electrode (GCE) via solvent casting method was studied. It is shown that the MWCNT/TiO2/GCE exhibits remarkable improvement in analytical response as compar...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English English |
Published: |
Chemical Publishing
2011
|
Online Access: | http://psasir.upm.edu.my/id/eprint/24764/1/Electrochemical%20detection%20of%20paracetamol%20at%20multi%20wall%20carbon%20nanotubes.pdf http://psasir.upm.edu.my/id/eprint/24764/ http://www.asianjournalofchemistry.co.in/Home.aspx |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.upm.eprints.24764 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.247642015-11-26T08:39:33Z http://psasir.upm.edu.my/id/eprint/24764/ Electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode. Ganchimeg, Perenlei Tan, Wee Tee Yusof, Nor Azah Goh, Joo Kheng Electrochemical behaviour of paracetamol at the multi wall carbon nanotubes/titanium dioxide (MWCNT/TiO2) composite film modified glassy carbon electrode (GCE) via solvent casting method was studied. It is shown that the MWCNT/TiO2/GCE exhibits remarkable improvement in analytical response as compared to other electrodes. Comparing the responses of the MWCNT/ TiO2/GCE with that obtained at the unmodified glassy carbon electrode, the peak currents were enhanced significantly by 8.5 folds (oxidation peak) and 11.0 folds (reduction peak), which showed stable response with enhanced selectivity and sensitivity. A linear calibration plot having a correlation coefficient of 0.991 was obtained in the concentration range of 0.01-0.12 mM paracetamol. The detection limit for the detection of paracetamol was calculated as 11.77 μM based on 3 σ/m. The method was applied in the determination of paracetamol in commercial tablets. The recoveries of the composite modified electrode obtained were 95.2 and 96.2 % for five determinations. Chemical Publishing 2011 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/24764/1/Electrochemical%20detection%20of%20paracetamol%20at%20multi%20wall%20carbon%20nanotubes.pdf Ganchimeg, Perenlei and Tan, Wee Tee and Yusof, Nor Azah and Goh, Joo Kheng (2011) Electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode. Asian Journal of Chemistry, 23 (7). pp. 3143-3147. ISSN 0970-7077 http://www.asianjournalofchemistry.co.in/Home.aspx English |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English English |
description |
Electrochemical behaviour of paracetamol at the multi wall carbon nanotubes/titanium dioxide (MWCNT/TiO2) composite film modified glassy carbon electrode (GCE) via solvent casting method was studied. It is shown that the MWCNT/TiO2/GCE exhibits remarkable improvement in analytical response as compared to other electrodes. Comparing the responses of the MWCNT/ TiO2/GCE with that obtained at the unmodified glassy carbon electrode, the peak currents were enhanced significantly by 8.5 folds (oxidation peak) and 11.0 folds (reduction peak), which showed stable response with enhanced selectivity and sensitivity. A linear calibration plot having a correlation coefficient of 0.991 was obtained in the concentration range of 0.01-0.12 mM paracetamol. The detection limit for the detection of paracetamol was calculated as 11.77 μM based on 3 σ/m. The method was applied in the determination of paracetamol in commercial tablets. The recoveries of the composite modified electrode obtained were 95.2 and 96.2 % for five determinations. |
format |
Article |
author |
Ganchimeg, Perenlei Tan, Wee Tee Yusof, Nor Azah Goh, Joo Kheng |
spellingShingle |
Ganchimeg, Perenlei Tan, Wee Tee Yusof, Nor Azah Goh, Joo Kheng Electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode. |
author_facet |
Ganchimeg, Perenlei Tan, Wee Tee Yusof, Nor Azah Goh, Joo Kheng |
author_sort |
Ganchimeg, Perenlei |
title |
Electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode. |
title_short |
Electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode. |
title_full |
Electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode. |
title_fullStr |
Electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode. |
title_full_unstemmed |
Electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode. |
title_sort |
electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode. |
publisher |
Chemical Publishing |
publishDate |
2011 |
url |
http://psasir.upm.edu.my/id/eprint/24764/1/Electrochemical%20detection%20of%20paracetamol%20at%20multi%20wall%20carbon%20nanotubes.pdf http://psasir.upm.edu.my/id/eprint/24764/ http://www.asianjournalofchemistry.co.in/Home.aspx |
_version_ |
1643828458755719168 |
score |
13.211869 |