Electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode.

Electrochemical behaviour of paracetamol at the multi wall carbon nanotubes/titanium dioxide (MWCNT/TiO2) composite film modified glassy carbon electrode (GCE) via solvent casting method was studied. It is shown that the MWCNT/TiO2/GCE exhibits remarkable improvement in analytical response as compar...

Full description

Saved in:
Bibliographic Details
Main Authors: Ganchimeg, Perenlei, Tan, Wee Tee, Yusof, Nor Azah, Goh, Joo Kheng
Format: Article
Language:English
English
Published: Chemical Publishing 2011
Online Access:http://psasir.upm.edu.my/id/eprint/24764/1/Electrochemical%20detection%20of%20paracetamol%20at%20multi%20wall%20carbon%20nanotubes.pdf
http://psasir.upm.edu.my/id/eprint/24764/
http://www.asianjournalofchemistry.co.in/Home.aspx
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.24764
record_format eprints
spelling my.upm.eprints.247642015-11-26T08:39:33Z http://psasir.upm.edu.my/id/eprint/24764/ Electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode. Ganchimeg, Perenlei Tan, Wee Tee Yusof, Nor Azah Goh, Joo Kheng Electrochemical behaviour of paracetamol at the multi wall carbon nanotubes/titanium dioxide (MWCNT/TiO2) composite film modified glassy carbon electrode (GCE) via solvent casting method was studied. It is shown that the MWCNT/TiO2/GCE exhibits remarkable improvement in analytical response as compared to other electrodes. Comparing the responses of the MWCNT/ TiO2/GCE with that obtained at the unmodified glassy carbon electrode, the peak currents were enhanced significantly by 8.5 folds (oxidation peak) and 11.0 folds (reduction peak), which showed stable response with enhanced selectivity and sensitivity. A linear calibration plot having a correlation coefficient of 0.991 was obtained in the concentration range of 0.01-0.12 mM paracetamol. The detection limit for the detection of paracetamol was calculated as 11.77 μM based on 3 σ/m. The method was applied in the determination of paracetamol in commercial tablets. The recoveries of the composite modified electrode obtained were 95.2 and 96.2 % for five determinations. Chemical Publishing 2011 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/24764/1/Electrochemical%20detection%20of%20paracetamol%20at%20multi%20wall%20carbon%20nanotubes.pdf Ganchimeg, Perenlei and Tan, Wee Tee and Yusof, Nor Azah and Goh, Joo Kheng (2011) Electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode. Asian Journal of Chemistry, 23 (7). pp. 3143-3147. ISSN 0970-7077 http://www.asianjournalofchemistry.co.in/Home.aspx English
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
English
description Electrochemical behaviour of paracetamol at the multi wall carbon nanotubes/titanium dioxide (MWCNT/TiO2) composite film modified glassy carbon electrode (GCE) via solvent casting method was studied. It is shown that the MWCNT/TiO2/GCE exhibits remarkable improvement in analytical response as compared to other electrodes. Comparing the responses of the MWCNT/ TiO2/GCE with that obtained at the unmodified glassy carbon electrode, the peak currents were enhanced significantly by 8.5 folds (oxidation peak) and 11.0 folds (reduction peak), which showed stable response with enhanced selectivity and sensitivity. A linear calibration plot having a correlation coefficient of 0.991 was obtained in the concentration range of 0.01-0.12 mM paracetamol. The detection limit for the detection of paracetamol was calculated as 11.77 μM based on 3 σ/m. The method was applied in the determination of paracetamol in commercial tablets. The recoveries of the composite modified electrode obtained were 95.2 and 96.2 % for five determinations.
format Article
author Ganchimeg, Perenlei
Tan, Wee Tee
Yusof, Nor Azah
Goh, Joo Kheng
spellingShingle Ganchimeg, Perenlei
Tan, Wee Tee
Yusof, Nor Azah
Goh, Joo Kheng
Electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode.
author_facet Ganchimeg, Perenlei
Tan, Wee Tee
Yusof, Nor Azah
Goh, Joo Kheng
author_sort Ganchimeg, Perenlei
title Electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode.
title_short Electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode.
title_full Electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode.
title_fullStr Electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode.
title_full_unstemmed Electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode.
title_sort electrochemical detection of paracetamol at multi wall carbon nanotubes/titanium dioxide composite modified electrode.
publisher Chemical Publishing
publishDate 2011
url http://psasir.upm.edu.my/id/eprint/24764/1/Electrochemical%20detection%20of%20paracetamol%20at%20multi%20wall%20carbon%20nanotubes.pdf
http://psasir.upm.edu.my/id/eprint/24764/
http://www.asianjournalofchemistry.co.in/Home.aspx
_version_ 1643828458755719168
score 13.211869