Preliminary evaluation of a hydrophilic microfiltration membrane in treating high strength wastewater

In this study, two types of flat sheet membranes were produced and tested in the laboratory. These types of membranes are hydrophilic and hydrophobic flat sheet membranes. The membranes were prepared using a phase-inversion technique. Three synthetic based polymers were used to produce the membrane....

Full description

Saved in:
Bibliographic Details
Main Authors: Mohamed Ali, Thamer Ahmad, Megat Mohd Noor, Megat Johari, Abdullah, Abdul Ghani Liew
Format: Article
Language:English
Published: Taylor & Francis 2009
Online Access:http://psasir.upm.edu.my/id/eprint/16296/1/Preliminary%20evaluation%20of%20a%20hydrophilic%20microfiltration%20membrane%20in%20treating%20high%20strength%20wastewater.pdf
http://psasir.upm.edu.my/id/eprint/16296/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.16296
record_format eprints
spelling my.upm.eprints.162962016-03-11T08:20:33Z http://psasir.upm.edu.my/id/eprint/16296/ Preliminary evaluation of a hydrophilic microfiltration membrane in treating high strength wastewater Mohamed Ali, Thamer Ahmad Megat Mohd Noor, Megat Johari Abdullah, Abdul Ghani Liew In this study, two types of flat sheet membranes were produced and tested in the laboratory. These types of membranes are hydrophilic and hydrophobic flat sheet membranes. The membranes were prepared using a phase-inversion technique. Three synthetic based polymers were used to produce the membrane. These polymers are polysulfone (PSF), polyethylene glycol (PEG), and N-methyl- 2-pyrrolidone (NMP). Fourteen polymer solutions were formulated by Response Surface Method and the polymers concentrations used were 15 wt % for PSF, 30–40 wt % for PEG and 45–55 wt % for NMP. The produced membranes were physically characterized by scanning electron microscope (SEM) measurements of their top surface and cross-section images. The produced membranes are used to test the flux value for pure water, synthetic wastewater and raw wastewater using a bench scale unit. Meanwhile, the rejection performance is evaluated using synthetic wastewater and raw wastewater. The pure water flux for the hydrophobic membrane ranges from 78.45 L/m2h to 88.05 L/m2h, while pure water flux for the hydrophilic membrane ranges from 41.92 L/m2h to 52.25 L/m2h. Meanwhile, the COD rejection rate from raw wastewater was greater for the hydrophilic membrane (58%) compared to the hydrophobic membrane (42%). Results obtained from the bench scale unit show a gradual increase in the percentage removal of COD, BOB and TOC with time and it increased from 0 to 75% from the 1st day to the 8th day while only a 20% increment was observed from the 8th day up to the end of the test. But, the percentage removal obtained form hydrophilic membrane is slightly higher than the percentage removal of the hydrophobic membrane. Taylor & Francis 2009 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/16296/1/Preliminary%20evaluation%20of%20a%20hydrophilic%20microfiltration%20membrane%20in%20treating%20high%20strength%20wastewater.pdf Mohamed Ali, Thamer Ahmad and Megat Mohd Noor, Megat Johari and Abdullah, Abdul Ghani Liew (2009) Preliminary evaluation of a hydrophilic microfiltration membrane in treating high strength wastewater. Desalination and Water Treatment, 10 (1-3). pp. 272-280. ISSN 1944-3994; ESSN: 1944-3986 10.5004/dwt.2009.928
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description In this study, two types of flat sheet membranes were produced and tested in the laboratory. These types of membranes are hydrophilic and hydrophobic flat sheet membranes. The membranes were prepared using a phase-inversion technique. Three synthetic based polymers were used to produce the membrane. These polymers are polysulfone (PSF), polyethylene glycol (PEG), and N-methyl- 2-pyrrolidone (NMP). Fourteen polymer solutions were formulated by Response Surface Method and the polymers concentrations used were 15 wt % for PSF, 30–40 wt % for PEG and 45–55 wt % for NMP. The produced membranes were physically characterized by scanning electron microscope (SEM) measurements of their top surface and cross-section images. The produced membranes are used to test the flux value for pure water, synthetic wastewater and raw wastewater using a bench scale unit. Meanwhile, the rejection performance is evaluated using synthetic wastewater and raw wastewater. The pure water flux for the hydrophobic membrane ranges from 78.45 L/m2h to 88.05 L/m2h, while pure water flux for the hydrophilic membrane ranges from 41.92 L/m2h to 52.25 L/m2h. Meanwhile, the COD rejection rate from raw wastewater was greater for the hydrophilic membrane (58%) compared to the hydrophobic membrane (42%). Results obtained from the bench scale unit show a gradual increase in the percentage removal of COD, BOB and TOC with time and it increased from 0 to 75% from the 1st day to the 8th day while only a 20% increment was observed from the 8th day up to the end of the test. But, the percentage removal obtained form hydrophilic membrane is slightly higher than the percentage removal of the hydrophobic membrane.
format Article
author Mohamed Ali, Thamer Ahmad
Megat Mohd Noor, Megat Johari
Abdullah, Abdul Ghani Liew
spellingShingle Mohamed Ali, Thamer Ahmad
Megat Mohd Noor, Megat Johari
Abdullah, Abdul Ghani Liew
Preliminary evaluation of a hydrophilic microfiltration membrane in treating high strength wastewater
author_facet Mohamed Ali, Thamer Ahmad
Megat Mohd Noor, Megat Johari
Abdullah, Abdul Ghani Liew
author_sort Mohamed Ali, Thamer Ahmad
title Preliminary evaluation of a hydrophilic microfiltration membrane in treating high strength wastewater
title_short Preliminary evaluation of a hydrophilic microfiltration membrane in treating high strength wastewater
title_full Preliminary evaluation of a hydrophilic microfiltration membrane in treating high strength wastewater
title_fullStr Preliminary evaluation of a hydrophilic microfiltration membrane in treating high strength wastewater
title_full_unstemmed Preliminary evaluation of a hydrophilic microfiltration membrane in treating high strength wastewater
title_sort preliminary evaluation of a hydrophilic microfiltration membrane in treating high strength wastewater
publisher Taylor & Francis
publishDate 2009
url http://psasir.upm.edu.my/id/eprint/16296/1/Preliminary%20evaluation%20of%20a%20hydrophilic%20microfiltration%20membrane%20in%20treating%20high%20strength%20wastewater.pdf
http://psasir.upm.edu.my/id/eprint/16296/
_version_ 1643826172053684224
score 13.211869