Evaluation of outer rotor embedded PMSM using segmented stator

To enhance the motor's efficiency, experts prioritize the optimization of the Permanent Magnet Synchronous Motor (PMSM) construction by introducing the consequent-pole (CP) PM rotor which decrease the reliance on PM rotors and decreases the costs by reducing the volume of PM by 30% [1]. A...

Full description

Saved in:
Bibliographic Details
Main Authors: Hairulnizam, Hairul Faizi, Misron, Norhisam, Ibrahim, Nur Amira, Harun @ Ramli, Hafiz Rashidi, Vaithilingam, Chockalingam Aravind, Hanamoto, Tsuyoshi
Format: Conference or Workshop Item
Language:English
Published: 2024
Online Access:http://psasir.upm.edu.my/id/eprint/115146/1/115146.pdf
http://psasir.upm.edu.my/id/eprint/115146/
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To enhance the motor's efficiency, experts prioritize the optimization of the Permanent Magnet Synchronous Motor (PMSM) construction by introducing the consequent-pole (CP) PM rotor which decrease the reliance on PM rotors and decreases the costs by reducing the volume of PM by 30% [1]. Additionally, the external orientation of rotor may have a high torque density, it requires a significant amount of rare-earth PM material. A PM motor with a segmented stator design has the potential to reduce costs, increase flexibility, and minimize windings. Furthermore, the incorporation of a segmented stator can enhance the motor's output torque, elevate both the mean and peak torque, and reduce the cogging torque