Development of a single-run liquid chromatography-mass spectrometry analysis for the detection of 11 multiclass contaminants of emerging concern using a direct filtration method

In toxicological analysis, the analytical validation method is important to assess the exact risk of contaminants of emerging concern in the environment. Syringe filters are mainly used to remove impurities from sample solutions. However, the loss of analyte to the syringe filter could be considerab...

Full description

Saved in:
Bibliographic Details
Main Authors: Razak, Muhammad Raznisyafiq, Aris, Ahmad Zaharin, Sukatis, Fahren Fazzer, Mohd Zaki, Muhammad Rozaimi, Zainuddin, Azim Haziq, Mohamad Haron, Didi Erwandi, Md Yusoff, Fatimah, Yusof, Zetty Norhana Balia
Format: Article
Published: Wiley 2022
Online Access:http://psasir.upm.edu.my/id/eprint/100601/
https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/abs/10.1002/jssc.202200282
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.100601
record_format eprints
spelling my.upm.eprints.1006012023-10-09T18:42:45Z http://psasir.upm.edu.my/id/eprint/100601/ Development of a single-run liquid chromatography-mass spectrometry analysis for the detection of 11 multiclass contaminants of emerging concern using a direct filtration method Razak, Muhammad Raznisyafiq Aris, Ahmad Zaharin Sukatis, Fahren Fazzer Mohd Zaki, Muhammad Rozaimi Zainuddin, Azim Haziq Mohamad Haron, Didi Erwandi Md Yusoff, Fatimah Yusof, Zetty Norhana Balia In toxicological analysis, the analytical validation method is important to assess the exact risk of contaminants of emerging concern in the environment. Syringe filters are mainly used to remove impurities from sample solutions. However, the loss of analyte to the syringe filter could be considerable, causing an underestimate of the analyte concentrations. The current study develops and validates simultaneous liquid chromatography-mass spectrometry analysis using a direct filtration method to detect four groups of contaminants of emerging concern. The adsorption of the analyte onto three different matrices and six types of syringe filters is reported. The lowest adsorption of analytes was observed in methanol (16.72%), followed by deionized water (48.19%) and filtered surface lake water (48.94%). Irrespective of the type of the matrices, the lowest average adsorption by the syringe filter was observed in the 0.45 μm polypropylene membrane (15.15%), followed by the 0.20 μm polypropylene membrane (16.10%), the 0.20 μm regenerated cellulose (16.15%), the 0.20 μm polytetrafluoroethylene membrane (47.38%), the 0.45 μm nylon membrane (64.87%) and the 0.20 μm nylon membrane (71.30%). In conclusion, the recommended syringe filter membranes for contaminants of emerging concern analysis are polypropylene membranes and regenerated cellulose, regardless of the matrix used. Wiley 2022-11-07 Article PeerReviewed Razak, Muhammad Raznisyafiq and Aris, Ahmad Zaharin and Sukatis, Fahren Fazzer and Mohd Zaki, Muhammad Rozaimi and Zainuddin, Azim Haziq and Mohamad Haron, Didi Erwandi and Md Yusoff, Fatimah and Yusof, Zetty Norhana Balia (2022) Development of a single-run liquid chromatography-mass spectrometry analysis for the detection of 11 multiclass contaminants of emerging concern using a direct filtration method. Journal of Separation Science, 46 (1). art. no. 2200282. ISSN 1615-9306; ESSN: 1615-9314 https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/abs/10.1002/jssc.202200282 10.1002/jssc.202200282
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
description In toxicological analysis, the analytical validation method is important to assess the exact risk of contaminants of emerging concern in the environment. Syringe filters are mainly used to remove impurities from sample solutions. However, the loss of analyte to the syringe filter could be considerable, causing an underestimate of the analyte concentrations. The current study develops and validates simultaneous liquid chromatography-mass spectrometry analysis using a direct filtration method to detect four groups of contaminants of emerging concern. The adsorption of the analyte onto three different matrices and six types of syringe filters is reported. The lowest adsorption of analytes was observed in methanol (16.72%), followed by deionized water (48.19%) and filtered surface lake water (48.94%). Irrespective of the type of the matrices, the lowest average adsorption by the syringe filter was observed in the 0.45 μm polypropylene membrane (15.15%), followed by the 0.20 μm polypropylene membrane (16.10%), the 0.20 μm regenerated cellulose (16.15%), the 0.20 μm polytetrafluoroethylene membrane (47.38%), the 0.45 μm nylon membrane (64.87%) and the 0.20 μm nylon membrane (71.30%). In conclusion, the recommended syringe filter membranes for contaminants of emerging concern analysis are polypropylene membranes and regenerated cellulose, regardless of the matrix used.
format Article
author Razak, Muhammad Raznisyafiq
Aris, Ahmad Zaharin
Sukatis, Fahren Fazzer
Mohd Zaki, Muhammad Rozaimi
Zainuddin, Azim Haziq
Mohamad Haron, Didi Erwandi
Md Yusoff, Fatimah
Yusof, Zetty Norhana Balia
spellingShingle Razak, Muhammad Raznisyafiq
Aris, Ahmad Zaharin
Sukatis, Fahren Fazzer
Mohd Zaki, Muhammad Rozaimi
Zainuddin, Azim Haziq
Mohamad Haron, Didi Erwandi
Md Yusoff, Fatimah
Yusof, Zetty Norhana Balia
Development of a single-run liquid chromatography-mass spectrometry analysis for the detection of 11 multiclass contaminants of emerging concern using a direct filtration method
author_facet Razak, Muhammad Raznisyafiq
Aris, Ahmad Zaharin
Sukatis, Fahren Fazzer
Mohd Zaki, Muhammad Rozaimi
Zainuddin, Azim Haziq
Mohamad Haron, Didi Erwandi
Md Yusoff, Fatimah
Yusof, Zetty Norhana Balia
author_sort Razak, Muhammad Raznisyafiq
title Development of a single-run liquid chromatography-mass spectrometry analysis for the detection of 11 multiclass contaminants of emerging concern using a direct filtration method
title_short Development of a single-run liquid chromatography-mass spectrometry analysis for the detection of 11 multiclass contaminants of emerging concern using a direct filtration method
title_full Development of a single-run liquid chromatography-mass spectrometry analysis for the detection of 11 multiclass contaminants of emerging concern using a direct filtration method
title_fullStr Development of a single-run liquid chromatography-mass spectrometry analysis for the detection of 11 multiclass contaminants of emerging concern using a direct filtration method
title_full_unstemmed Development of a single-run liquid chromatography-mass spectrometry analysis for the detection of 11 multiclass contaminants of emerging concern using a direct filtration method
title_sort development of a single-run liquid chromatography-mass spectrometry analysis for the detection of 11 multiclass contaminants of emerging concern using a direct filtration method
publisher Wiley
publishDate 2022
url http://psasir.upm.edu.my/id/eprint/100601/
https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/abs/10.1002/jssc.202200282
_version_ 1781706665001746432
score 13.211869