Testing and rating non-ducted air conditioners in Malaysia: The applicability of ISO standard 5151

Air conditioners are one of the major energy-consuming appliances in the Malaysian domestic sector. According to a load survey, air conditioners account for around 8.3% of the total residential electricity consumption in Malaysia. To reduce the energy consumption in this sector, Malaysia Energy Cent...

Full description

Saved in:
Bibliographic Details
Main Authors: Mahlia, T.M.I., Masjuki, H.H., Choudhury, I.A., Saidur, R.
Format:
Published: 2017
Online Access:http://dspace.uniten.edu.my/jspui/handle/123456789/6287
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-6287
record_format dspace
spelling my.uniten.dspace-62872017-12-08T09:12:37Z Testing and rating non-ducted air conditioners in Malaysia: The applicability of ISO standard 5151 Mahlia, T.M.I. Masjuki, H.H. Choudhury, I.A. Saidur, R. Air conditioners are one of the major energy-consuming appliances in the Malaysian domestic sector. According to a load survey, air conditioners account for around 8.3% of the total residential electricity consumption in Malaysia. To reduce the energy consumption in this sector, Malaysia Energy Center is considering implementing minimum energy efficiency standards for room air conditioners sometime in the coming year. The first step towards adopting energy efficiency standards is to create a test procedure for rating and testing this appliance. An energy test procedure is the technical foundation for alt energy efficiency standards, energy labels, and other related programs. As room air conditioners are a climate-dependent appliance, the climatic condition for a particular country or region is an important determinant in developing the test conditions. Therefore, before setting the test conditions, the requirements for a specific country and region must be clarified. This article is an analysis of the applicability of ISO 5151 nonducted air conditioner test conditions, based on the climatic conditions in Malaysia. International adoption of ISO 5151 by several countries is also discussed. There is a trend towards international harmonization of appliance test standards; this work can be considered as support to that end. 2017-12-08T09:12:37Z 2017-12-08T09:12:37Z 2002 http://dspace.uniten.edu.my/jspui/handle/123456789/6287
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description Air conditioners are one of the major energy-consuming appliances in the Malaysian domestic sector. According to a load survey, air conditioners account for around 8.3% of the total residential electricity consumption in Malaysia. To reduce the energy consumption in this sector, Malaysia Energy Center is considering implementing minimum energy efficiency standards for room air conditioners sometime in the coming year. The first step towards adopting energy efficiency standards is to create a test procedure for rating and testing this appliance. An energy test procedure is the technical foundation for alt energy efficiency standards, energy labels, and other related programs. As room air conditioners are a climate-dependent appliance, the climatic condition for a particular country or region is an important determinant in developing the test conditions. Therefore, before setting the test conditions, the requirements for a specific country and region must be clarified. This article is an analysis of the applicability of ISO 5151 nonducted air conditioner test conditions, based on the climatic conditions in Malaysia. International adoption of ISO 5151 by several countries is also discussed. There is a trend towards international harmonization of appliance test standards; this work can be considered as support to that end.
format
author Mahlia, T.M.I.
Masjuki, H.H.
Choudhury, I.A.
Saidur, R.
spellingShingle Mahlia, T.M.I.
Masjuki, H.H.
Choudhury, I.A.
Saidur, R.
Testing and rating non-ducted air conditioners in Malaysia: The applicability of ISO standard 5151
author_facet Mahlia, T.M.I.
Masjuki, H.H.
Choudhury, I.A.
Saidur, R.
author_sort Mahlia, T.M.I.
title Testing and rating non-ducted air conditioners in Malaysia: The applicability of ISO standard 5151
title_short Testing and rating non-ducted air conditioners in Malaysia: The applicability of ISO standard 5151
title_full Testing and rating non-ducted air conditioners in Malaysia: The applicability of ISO standard 5151
title_fullStr Testing and rating non-ducted air conditioners in Malaysia: The applicability of ISO standard 5151
title_full_unstemmed Testing and rating non-ducted air conditioners in Malaysia: The applicability of ISO standard 5151
title_sort testing and rating non-ducted air conditioners in malaysia: the applicability of iso standard 5151
publishDate 2017
url http://dspace.uniten.edu.my/jspui/handle/123456789/6287
_version_ 1644493896542060544
score 13.222552