Development of a simple in situ instrumentation for detection of breath alcohol and gas leak
The objective of this project is to develop a multiple-detector-system which consists of two systems that are toxic gas detector system and breath alcohol detector. A microcontroller of PIC 16F84, a gas sensor (TGS822), an analog to digital (A/D) TLC 549, and LCD alphanumeric display were used. Both...
Saved in:
Main Authors: | , , , |
---|---|
Format: | |
Published: |
2017
|
Online Access: | http://dspace.uniten.edu.my:8080/jspui/handle/123456789/5333 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-5333 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-53332017-11-15T02:57:35Z Development of a simple in situ instrumentation for detection of breath alcohol and gas leak Wagiran, R. Chong, A.G.E. Ahmad, I. Salleh, A.B. The objective of this project is to develop a multiple-detector-system which consists of two systems that are toxic gas detector system and breath alcohol detector. A microcontroller of PIC 16F84, a gas sensor (TGS822), an analog to digital (A/D) TLC 549, and LCD alphanumeric display were used. Both systems are mounted on the same PCB board, a DPDT switch is used for the purpose for switching systems either switch from toxic gas detector system to breath alcohol detector system and vice versa. The systems were tested using butane gas from cigarette's lighter as well as from human's breath and it worked satisfactory. © 2002 IEEE. 2017-11-15T02:57:35Z 2017-11-15T02:57:35Z 2002 http://dspace.uniten.edu.my:8080/jspui/handle/123456789/5333 |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
The objective of this project is to develop a multiple-detector-system which consists of two systems that are toxic gas detector system and breath alcohol detector. A microcontroller of PIC 16F84, a gas sensor (TGS822), an analog to digital (A/D) TLC 549, and LCD alphanumeric display were used. Both systems are mounted on the same PCB board, a DPDT switch is used for the purpose for switching systems either switch from toxic gas detector system to breath alcohol detector system and vice versa. The systems were tested using butane gas from cigarette's lighter as well as from human's breath and it worked satisfactory. © 2002 IEEE. |
format |
|
author |
Wagiran, R. Chong, A.G.E. Ahmad, I. Salleh, A.B. |
spellingShingle |
Wagiran, R. Chong, A.G.E. Ahmad, I. Salleh, A.B. Development of a simple in situ instrumentation for detection of breath alcohol and gas leak |
author_facet |
Wagiran, R. Chong, A.G.E. Ahmad, I. Salleh, A.B. |
author_sort |
Wagiran, R. |
title |
Development of a simple in situ instrumentation for detection of breath alcohol and gas leak |
title_short |
Development of a simple in situ instrumentation for detection of breath alcohol and gas leak |
title_full |
Development of a simple in situ instrumentation for detection of breath alcohol and gas leak |
title_fullStr |
Development of a simple in situ instrumentation for detection of breath alcohol and gas leak |
title_full_unstemmed |
Development of a simple in situ instrumentation for detection of breath alcohol and gas leak |
title_sort |
development of a simple in situ instrumentation for detection of breath alcohol and gas leak |
publishDate |
2017 |
url |
http://dspace.uniten.edu.my:8080/jspui/handle/123456789/5333 |
_version_ |
1644493660326199296 |
score |
13.211869 |