Development of a simple in situ instrumentation for detection of breath alcohol and gas leak

The objective of this project is to develop a multiple-detector-system which consists of two systems that are toxic gas detector system and breath alcohol detector. A microcontroller of PIC 16F84, a gas sensor (TGS822), an analog to digital (A/D) TLC 549, and LCD alphanumeric display were used. Both...

Full description

Saved in:
Bibliographic Details
Main Authors: Wagiran, R., Chong, A.G.E., Ahmad, I., Salleh, A.B.
Format:
Published: 2017
Online Access:http://dspace.uniten.edu.my:8080/jspui/handle/123456789/5333
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-5333
record_format dspace
spelling my.uniten.dspace-53332017-11-15T02:57:35Z Development of a simple in situ instrumentation for detection of breath alcohol and gas leak Wagiran, R. Chong, A.G.E. Ahmad, I. Salleh, A.B. The objective of this project is to develop a multiple-detector-system which consists of two systems that are toxic gas detector system and breath alcohol detector. A microcontroller of PIC 16F84, a gas sensor (TGS822), an analog to digital (A/D) TLC 549, and LCD alphanumeric display were used. Both systems are mounted on the same PCB board, a DPDT switch is used for the purpose for switching systems either switch from toxic gas detector system to breath alcohol detector system and vice versa. The systems were tested using butane gas from cigarette's lighter as well as from human's breath and it worked satisfactory. © 2002 IEEE. 2017-11-15T02:57:35Z 2017-11-15T02:57:35Z 2002 http://dspace.uniten.edu.my:8080/jspui/handle/123456789/5333
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description The objective of this project is to develop a multiple-detector-system which consists of two systems that are toxic gas detector system and breath alcohol detector. A microcontroller of PIC 16F84, a gas sensor (TGS822), an analog to digital (A/D) TLC 549, and LCD alphanumeric display were used. Both systems are mounted on the same PCB board, a DPDT switch is used for the purpose for switching systems either switch from toxic gas detector system to breath alcohol detector system and vice versa. The systems were tested using butane gas from cigarette's lighter as well as from human's breath and it worked satisfactory. © 2002 IEEE.
format
author Wagiran, R.
Chong, A.G.E.
Ahmad, I.
Salleh, A.B.
spellingShingle Wagiran, R.
Chong, A.G.E.
Ahmad, I.
Salleh, A.B.
Development of a simple in situ instrumentation for detection of breath alcohol and gas leak
author_facet Wagiran, R.
Chong, A.G.E.
Ahmad, I.
Salleh, A.B.
author_sort Wagiran, R.
title Development of a simple in situ instrumentation for detection of breath alcohol and gas leak
title_short Development of a simple in situ instrumentation for detection of breath alcohol and gas leak
title_full Development of a simple in situ instrumentation for detection of breath alcohol and gas leak
title_fullStr Development of a simple in situ instrumentation for detection of breath alcohol and gas leak
title_full_unstemmed Development of a simple in situ instrumentation for detection of breath alcohol and gas leak
title_sort development of a simple in situ instrumentation for detection of breath alcohol and gas leak
publishDate 2017
url http://dspace.uniten.edu.my:8080/jspui/handle/123456789/5333
_version_ 1644493660326199296
score 13.211869