Field study on thermal comfort in Malaysia

A field study on the environmental conditions and occupant comfort was carried out in two schools, which is a primary and secondary school, and in a public waiting area in a health clinic in Johor Bahru, located in the southern region of Malaysia. These buildings were mechanically ventilated by fans...

Full description

Saved in:
Bibliographic Details
Main Authors: Hussein I., Rahman M.H.A.
Other Authors: 7006902818
Format: Article
Published: EuroJournals, Inc. 2023
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-30898
record_format dspace
spelling my.uniten.dspace-308982023-12-29T15:55:30Z Field study on thermal comfort in Malaysia Hussein I. Rahman M.H.A. 7006902818 15047138000 Classrooms Field study Thermal comfort Tropics A field study on the environmental conditions and occupant comfort was carried out in two schools, which is a primary and secondary school, and in a public waiting area in a health clinic in Johor Bahru, located in the southern region of Malaysia. These buildings were mechanically ventilated by fans. The study was made in three different days from morning until noon as to get variation of temperatures, collecting a full set of objective physical measurements and subjective assessments through questionnaires. The measured environmental parameters were air temperature, relative humidity and air velocity. The subjective responses concern the judgment of the respondents about the thermal environment at the moment of measurements. The results obtained showed that more than 80% of the respondents found that their indoor thermal conditions acceptable even though the thermal sensation votes (TSV) exceeded those specified by ASHRAE Standard 55 and the environmental assessments exceeded the standard. The neutral temperature and comfort range were obtained through linear regression analysis of TSV and in the Fanger's PMV model. From the subjective assessment, it was found that the occupants can accept the thermal range beyond the ASHRAE comfort zone. In this study, it seems that the occupants in the tropic environment such as Malaysia have a higher heat tolerance and can adapt to the environment that they are used to. � EuroJournals Publishing Inc. 2009. Final 2023-12-29T07:55:30Z 2023-12-29T07:55:30Z 2009 Article 2-s2.0-70449090056 https://www.scopus.com/inward/record.uri?eid=2-s2.0-70449090056&partnerID=40&md5=108f979d4c4d7f32bc1cd09a9e0895a7 https://irepository.uniten.edu.my/handle/123456789/30898 37 1 134 152 EuroJournals, Inc. Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
topic Classrooms
Field study
Thermal comfort
Tropics
spellingShingle Classrooms
Field study
Thermal comfort
Tropics
Hussein I.
Rahman M.H.A.
Field study on thermal comfort in Malaysia
description A field study on the environmental conditions and occupant comfort was carried out in two schools, which is a primary and secondary school, and in a public waiting area in a health clinic in Johor Bahru, located in the southern region of Malaysia. These buildings were mechanically ventilated by fans. The study was made in three different days from morning until noon as to get variation of temperatures, collecting a full set of objective physical measurements and subjective assessments through questionnaires. The measured environmental parameters were air temperature, relative humidity and air velocity. The subjective responses concern the judgment of the respondents about the thermal environment at the moment of measurements. The results obtained showed that more than 80% of the respondents found that their indoor thermal conditions acceptable even though the thermal sensation votes (TSV) exceeded those specified by ASHRAE Standard 55 and the environmental assessments exceeded the standard. The neutral temperature and comfort range were obtained through linear regression analysis of TSV and in the Fanger's PMV model. From the subjective assessment, it was found that the occupants can accept the thermal range beyond the ASHRAE comfort zone. In this study, it seems that the occupants in the tropic environment such as Malaysia have a higher heat tolerance and can adapt to the environment that they are used to. � EuroJournals Publishing Inc. 2009.
author2 7006902818
author_facet 7006902818
Hussein I.
Rahman M.H.A.
format Article
author Hussein I.
Rahman M.H.A.
author_sort Hussein I.
title Field study on thermal comfort in Malaysia
title_short Field study on thermal comfort in Malaysia
title_full Field study on thermal comfort in Malaysia
title_fullStr Field study on thermal comfort in Malaysia
title_full_unstemmed Field study on thermal comfort in Malaysia
title_sort field study on thermal comfort in malaysia
publisher EuroJournals, Inc.
publishDate 2023
_version_ 1806424205480165376
score 13.222552