Determination of correlation functions of the oxide scale growth and the temperature increase
In this paper, a method for estimating the scale growth of superheater and reheater tubes of boiler and generating the constant B which is correlating the scale growth and the increased tube metal temperature, for different operational conditions is reported. This method utilizes an empirical formul...
Saved in:
Main Authors: | Salman B.H., Hamzah M.Z., Purbolaksono J., Inayat-Hussain J.I., Mohammed H.A., Muhieldeen M.W. |
---|---|
Other Authors: | 48461700800 |
Format: | Article |
Published: |
2023
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
A new method for estimating heat flux in superheater and reheater tubes
by: Purbolaksono J., et al.
Published: (2023) -
Evaluation on reheater tube failure
by: Purbolaksono J., et al.
Published: (2023) -
Estimation of oxide scale growth and temperature increase of high (9-12%) chromium martensitic steels of superheater tubes
by: Hamzah M.Z., et al.
Published: (2023) -
Investigation on wall thinning and creep damage in boiler tube due to scale formation
by: Begum S., et al.
Published: (2023) -
Failure investigation on reheater tube due to deposit and wall thinning
by: Purbolaksono J., et al.
Published: (2023)