Performance comparison of voltage stability indices for weak bus identification in power systems
Voltage collapse event is identified as complex and localized in nature but its effect is extensive once occurred. The vital effect of voltage collapse would be the total system collapse or blackouts which would cost a large loss to utility companies. Eventually, on- line monitoring of power system...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Conference paper |
Published: |
Institute of Physics Publishing
2023
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-30210 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-302102023-12-29T15:45:33Z Performance comparison of voltage stability indices for weak bus identification in power systems Verayiah R. Mohamed A. Shareef H. Abidin I.H.Z. 26431682500 57195440511 57189691198 35606640500 Complex networks Electric power systems System stability Voltage control Voltage stabilizing circuits Electric power utilities Fast voltage stability indices Performance comparison Power system networks Power system stability Under voltage load shedding Utility companies Voltage stability index bus transport conference proceeding electrical power electricity industry identification method monitoring system performance assessment Electric load shedding Voltage collapse event is identified as complex and localized in nature but its effect is extensive once occurred. The vital effect of voltage collapse would be the total system collapse or blackouts which would cost a large loss to utility companies. Eventually, on- line monitoring of power system stability has become an important factor for electric power utilities. The last utmost option to avert voltage collapse incident from occurring is by the implementation of under voltage load shedding scheme. The identification of location for load shedding is the main motivation of the study. The weakest bus in a power system is identified as the location for load shedding. This location is obtained using voltage stability index Ld. The performance and effectiveness of Ld index is compared with Fast Voltage Stability Index (FVSI) and Le Index. The results obtained indicate that Ld Index can be used to identify the weak bus in a power system and consequently for the placement of UVLS relays in a power system network. � Published under licence by IOP Publishing Ltd. Final 2023-12-29T07:45:33Z 2023-12-29T07:45:33Z 2013 Conference paper 10.1088/1755-1315/16/1/012022 2-s2.0-84881104051 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84881104051&doi=10.1088%2f1755-1315%2f16%2f1%2f012022&partnerID=40&md5=e94e4c91de1d14711cebf18c662804ce https://irepository.uniten.edu.my/handle/123456789/30210 16 1 12022 All Open Access; Gold Open Access Institute of Physics Publishing Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
topic |
Complex networks Electric power systems System stability Voltage control Voltage stabilizing circuits Electric power utilities Fast voltage stability indices Performance comparison Power system networks Power system stability Under voltage load shedding Utility companies Voltage stability index bus transport conference proceeding electrical power electricity industry identification method monitoring system performance assessment Electric load shedding |
spellingShingle |
Complex networks Electric power systems System stability Voltage control Voltage stabilizing circuits Electric power utilities Fast voltage stability indices Performance comparison Power system networks Power system stability Under voltage load shedding Utility companies Voltage stability index bus transport conference proceeding electrical power electricity industry identification method monitoring system performance assessment Electric load shedding Verayiah R. Mohamed A. Shareef H. Abidin I.H.Z. Performance comparison of voltage stability indices for weak bus identification in power systems |
description |
Voltage collapse event is identified as complex and localized in nature but its effect is extensive once occurred. The vital effect of voltage collapse would be the total system collapse or blackouts which would cost a large loss to utility companies. Eventually, on- line monitoring of power system stability has become an important factor for electric power utilities. The last utmost option to avert voltage collapse incident from occurring is by the implementation of under voltage load shedding scheme. The identification of location for load shedding is the main motivation of the study. The weakest bus in a power system is identified as the location for load shedding. This location is obtained using voltage stability index Ld. The performance and effectiveness of Ld index is compared with Fast Voltage Stability Index (FVSI) and Le Index. The results obtained indicate that Ld Index can be used to identify the weak bus in a power system and consequently for the placement of UVLS relays in a power system network. � Published under licence by IOP Publishing Ltd. |
author2 |
26431682500 |
author_facet |
26431682500 Verayiah R. Mohamed A. Shareef H. Abidin I.H.Z. |
format |
Conference paper |
author |
Verayiah R. Mohamed A. Shareef H. Abidin I.H.Z. |
author_sort |
Verayiah R. |
title |
Performance comparison of voltage stability indices for weak bus identification in power systems |
title_short |
Performance comparison of voltage stability indices for weak bus identification in power systems |
title_full |
Performance comparison of voltage stability indices for weak bus identification in power systems |
title_fullStr |
Performance comparison of voltage stability indices for weak bus identification in power systems |
title_full_unstemmed |
Performance comparison of voltage stability indices for weak bus identification in power systems |
title_sort |
performance comparison of voltage stability indices for weak bus identification in power systems |
publisher |
Institute of Physics Publishing |
publishDate |
2023 |
_version_ |
1806426337860124672 |
score |
13.211869 |