Root cause failure analysis of final superheater tube from a coal fired power station

This paper presents the root cause failure investigation ot final superheater tube of unit 5 Stesen Janaelektrik Sultan Salahuddin Abdul Aziz (SJSSAA) Kapar or better known as Kapar Energy Venture (KEV). KEV is the largest power plant in Malaysia with a generation capacity of 2420 MW and the only po...

詳細記述

保存先:
書誌詳細
主要な著者: Rahman M.M., Omar A.A., Ahmad J.
その他の著者: 55328831100
フォーマット: 論文
出版事項: Microscopy Society of Malaysia 2023
主題:
タグ: タグ追加