Effects of variations in generator inputs for small signal stability studies of a three machine nine bus network
Small signal stability causes small perturbations in the generator that can cause instability in the power network. It is generally known that small signal stability are directly related to the generator and load properties. This paper examines the effects of generator input variations on power syst...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
2023
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-29557 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-295572023-12-28T15:05:38Z Effects of variations in generator inputs for small signal stability studies of a three machine nine bus network Vijiyan H.N. Ramasamy A.K. Teng A.M. Ahmed S.K. 37066648400 16023154400 9742020600 25926812900 Eigen-analysis Generation modeling Participation factor Small signal stability Mathematical models Bus networks Bus systems Dynamic power systems Eigenanalysis Eigenvectors Generation modeling Load flow Load property Participation factor Participation factors Power networks Power system model Power system oscillations Power systems Small perturbations Small signal stability System stability Small signal stability causes small perturbations in the generator that can cause instability in the power network. It is generally known that small signal stability are directly related to the generator and load properties. This paper examines the effects of generator input variations on power system oscillations for a small signal stability study. Eigenvaules and eigenvectors are used to examine the stability of the power system. The dynamic power system's mathematical model is constructed and thus calculated using load flow and small signal stability toolbox on MATLAB. The power system model is based on a 3-machine 9-bus system that was modified to suit this study. In this paper, Participation Factors are a means to gauge the effects of variation in generation with other parameters on the network are also incorporated. Final 2023-12-28T07:05:38Z 2023-12-28T07:05:38Z 2011 Article 2-s2.0-79953281052 https://www.scopus.com/inward/record.uri?eid=2-s2.0-79953281052&partnerID=40&md5=b57a53143c60782d8179c0c7a11c73c1 https://irepository.uniten.edu.my/handle/123456789/29557 74 290 293 Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
topic |
Eigen-analysis Generation modeling Participation factor Small signal stability Mathematical models Bus networks Bus systems Dynamic power systems Eigenanalysis Eigenvectors Generation modeling Load flow Load property Participation factor Participation factors Power networks Power system model Power system oscillations Power systems Small perturbations Small signal stability System stability |
spellingShingle |
Eigen-analysis Generation modeling Participation factor Small signal stability Mathematical models Bus networks Bus systems Dynamic power systems Eigenanalysis Eigenvectors Generation modeling Load flow Load property Participation factor Participation factors Power networks Power system model Power system oscillations Power systems Small perturbations Small signal stability System stability Vijiyan H.N. Ramasamy A.K. Teng A.M. Ahmed S.K. Effects of variations in generator inputs for small signal stability studies of a three machine nine bus network |
description |
Small signal stability causes small perturbations in the generator that can cause instability in the power network. It is generally known that small signal stability are directly related to the generator and load properties. This paper examines the effects of generator input variations on power system oscillations for a small signal stability study. Eigenvaules and eigenvectors are used to examine the stability of the power system. The dynamic power system's mathematical model is constructed and thus calculated using load flow and small signal stability toolbox on MATLAB. The power system model is based on a 3-machine 9-bus system that was modified to suit this study. In this paper, Participation Factors are a means to gauge the effects of variation in generation with other parameters on the network are also incorporated. |
author2 |
37066648400 |
author_facet |
37066648400 Vijiyan H.N. Ramasamy A.K. Teng A.M. Ahmed S.K. |
format |
Article |
author |
Vijiyan H.N. Ramasamy A.K. Teng A.M. Ahmed S.K. |
author_sort |
Vijiyan H.N. |
title |
Effects of variations in generator inputs for small signal stability studies of a three machine nine bus network |
title_short |
Effects of variations in generator inputs for small signal stability studies of a three machine nine bus network |
title_full |
Effects of variations in generator inputs for small signal stability studies of a three machine nine bus network |
title_fullStr |
Effects of variations in generator inputs for small signal stability studies of a three machine nine bus network |
title_full_unstemmed |
Effects of variations in generator inputs for small signal stability studies of a three machine nine bus network |
title_sort |
effects of variations in generator inputs for small signal stability studies of a three machine nine bus network |
publishDate |
2023 |
_version_ |
1806425720604327936 |
score |
13.222552 |