DC traction power substation using eighteen-pulse rectifier transformer system

Twelve-pulse rectification system had been widely integrated in today�s DC traction power sub-station (DC-TPSS). This configuration had successfully mitigated low order harmonic distortion. As some research findings had confirmed that the DC voltage and current ripple factors may further minimize by...

Full description

Saved in:
Bibliographic Details
Main Authors: Toh C.L., Tan C.W.
Other Authors: 8690228000
Format: Article
Published: Institute of Advanced Engineering and Science 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-25848
record_format dspace
spelling my.uniten.dspace-258482023-05-29T17:05:15Z DC traction power substation using eighteen-pulse rectifier transformer system Toh C.L. Tan C.W. 8690228000 35216732200 Twelve-pulse rectification system had been widely integrated in today�s DC traction power sub-station (DC-TPSS). This configuration had successfully mitigated low order harmonic distortion. As some research findings had confirmed that the DC voltage and current ripple factors may further minimize by increasing the number of rectification pulses to 18, 24, or 36. This paper had presented a simulation study to investigate the prospect of implementing an eighteen-pulse rectification system in a DC-TPSS. The theory of phase-shifting transformer used to produce an 18-pulse rectifier is presented with simulation verification. Simulation result shows that 3.69% of grid current distortion index is recorded without installing any filters. In addition, the DC voltage and current ripple may also be further reduced for about 30% compared to a conventional twelve-pulse rectification system. � 2021, Institute of Advanced Engineering and Science. All rights reserved. Final 2023-05-29T09:05:15Z 2023-05-29T09:05:15Z 2021 Article 10.11591/ijpeds.v12.i4.pp2284-2294 2-s2.0-85118926560 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85118926560&doi=10.11591%2fijpeds.v12.i4.pp2284-2294&partnerID=40&md5=b44ce6001c8a886cb58a329a53a26163 https://irepository.uniten.edu.my/handle/123456789/25848 12 4 2284 2394 All Open Access, Gold, Green Institute of Advanced Engineering and Science Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description Twelve-pulse rectification system had been widely integrated in today�s DC traction power sub-station (DC-TPSS). This configuration had successfully mitigated low order harmonic distortion. As some research findings had confirmed that the DC voltage and current ripple factors may further minimize by increasing the number of rectification pulses to 18, 24, or 36. This paper had presented a simulation study to investigate the prospect of implementing an eighteen-pulse rectification system in a DC-TPSS. The theory of phase-shifting transformer used to produce an 18-pulse rectifier is presented with simulation verification. Simulation result shows that 3.69% of grid current distortion index is recorded without installing any filters. In addition, the DC voltage and current ripple may also be further reduced for about 30% compared to a conventional twelve-pulse rectification system. � 2021, Institute of Advanced Engineering and Science. All rights reserved.
author2 8690228000
author_facet 8690228000
Toh C.L.
Tan C.W.
format Article
author Toh C.L.
Tan C.W.
spellingShingle Toh C.L.
Tan C.W.
DC traction power substation using eighteen-pulse rectifier transformer system
author_sort Toh C.L.
title DC traction power substation using eighteen-pulse rectifier transformer system
title_short DC traction power substation using eighteen-pulse rectifier transformer system
title_full DC traction power substation using eighteen-pulse rectifier transformer system
title_fullStr DC traction power substation using eighteen-pulse rectifier transformer system
title_full_unstemmed DC traction power substation using eighteen-pulse rectifier transformer system
title_sort dc traction power substation using eighteen-pulse rectifier transformer system
publisher Institute of Advanced Engineering and Science
publishDate 2023
_version_ 1806423549565468672
score 13.222552