A review: Partial discharge sensor applications and classification technique in high voltage cable
Partial discharge (PD)can cause a failure at high voltage (HV) equipment. Internal discharge, surface discharge and corona discharge can be identified as PD types which can lead to HV system failure. Power cable is one of the major applications in transmission line and power distribution. Therefore,...
Saved in:
Main Authors: | , , , , , , |
---|---|
Other Authors: | |
Format: | Review |
Published: |
Institute of Advanced Scientific Research, Inc.
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-25677 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-256772023-05-29T16:12:36Z A review: Partial discharge sensor applications and classification technique in high voltage cable Auni W.N. Rohani M.N.K.H. Roslee N.F. Rosmi A.S. Kamaro M. Mohd Aizam T. Jalil M.A.A. 57218891545 57189241581 57819042100 57193830914 57218902479 57218898343 56178619100 Partial discharge (PD)can cause a failure at high voltage (HV) equipment. Internal discharge, surface discharge and corona discharge can be identified as PD types which can lead to HV system failure. Power cable is one of the major applications in transmission line and power distribution. Therefore, early detection of PD at power cable is important due to prevent any sign of failure. In this paper reviews on how the PD present in power cable and some methods of PD detection at HV equipment. This review highlight on some application of AE sensor and electrical sensor in power cable. Since the PD signals are hard to differentiate due to noise surrounding during experiment, de-noising techniques are proposed in order to remove unwanted PD signal. Next, three popular techniques like Adaptive Neuro-Fuzzy Inference system (ANFIS), Artificial Neural Network (ANN) and Support Vector Machine (SVM) are review in the section of classification of PD signal. Feature extraction act as input of PD classification also introduced to reduce the size of PD data. � 2020, Institute of Advanced Scientific Research, Inc. All rights reserved. Final 2023-05-29T08:12:36Z 2023-05-29T08:12:36Z 2020 Review 10.5373/JARDCS/V12SP7/20202229 2-s2.0-85090638765 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85090638765&doi=10.5373%2fJARDCS%2fV12SP7%2f20202229&partnerID=40&md5=fb43d0042b3f44900b14f92ba7819243 https://irepository.uniten.edu.my/handle/123456789/25677 12 7 Special Issue 1290 1301 Institute of Advanced Scientific Research, Inc. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Partial discharge (PD)can cause a failure at high voltage (HV) equipment. Internal discharge, surface discharge and corona discharge can be identified as PD types which can lead to HV system failure. Power cable is one of the major applications in transmission line and power distribution. Therefore, early detection of PD at power cable is important due to prevent any sign of failure. In this paper reviews on how the PD present in power cable and some methods of PD detection at HV equipment. This review highlight on some application of AE sensor and electrical sensor in power cable. Since the PD signals are hard to differentiate due to noise surrounding during experiment, de-noising techniques are proposed in order to remove unwanted PD signal. Next, three popular techniques like Adaptive Neuro-Fuzzy Inference system (ANFIS), Artificial Neural Network (ANN) and Support Vector Machine (SVM) are review in the section of classification of PD signal. Feature extraction act as input of PD classification also introduced to reduce the size of PD data. � 2020, Institute of Advanced Scientific Research, Inc. All rights reserved. |
author2 |
57218891545 |
author_facet |
57218891545 Auni W.N. Rohani M.N.K.H. Roslee N.F. Rosmi A.S. Kamaro M. Mohd Aizam T. Jalil M.A.A. |
format |
Review |
author |
Auni W.N. Rohani M.N.K.H. Roslee N.F. Rosmi A.S. Kamaro M. Mohd Aizam T. Jalil M.A.A. |
spellingShingle |
Auni W.N. Rohani M.N.K.H. Roslee N.F. Rosmi A.S. Kamaro M. Mohd Aizam T. Jalil M.A.A. A review: Partial discharge sensor applications and classification technique in high voltage cable |
author_sort |
Auni W.N. |
title |
A review: Partial discharge sensor applications and classification technique in high voltage cable |
title_short |
A review: Partial discharge sensor applications and classification technique in high voltage cable |
title_full |
A review: Partial discharge sensor applications and classification technique in high voltage cable |
title_fullStr |
A review: Partial discharge sensor applications and classification technique in high voltage cable |
title_full_unstemmed |
A review: Partial discharge sensor applications and classification technique in high voltage cable |
title_sort |
review: partial discharge sensor applications and classification technique in high voltage cable |
publisher |
Institute of Advanced Scientific Research, Inc. |
publishDate |
2023 |
_version_ |
1806427896113266688 |
score |
13.222552 |