Implementation and use of multi chamber arresters for 33kV overhead lines in Malaysia

Overhead lines; Bare overhead lines; Distribution lines; Lightning activity; Lightning detection; Lightning performance; Lightning strikes; Monitoring periods; Multi-chamber; Lightning

Saved in:
Bibliographic Details
Main Authors: Abdullah N., Osman M., Kadir M.Z.A.A., Hatta N.M., Ariffin M.F.
Other Authors: 26422769600
Format: Conference Paper
Published: Institute of Electrical and Electronics Engineers Inc. 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-24632
record_format dspace
spelling my.uniten.dspace-246322023-05-29T15:25:20Z Implementation and use of multi chamber arresters for 33kV overhead lines in Malaysia Abdullah N. Osman M. Kadir M.Z.A.A. Hatta N.M. Ariffin M.F. 26422769600 7201930315 25947297000 55611430000 35178958300 Overhead lines; Bare overhead lines; Distribution lines; Lightning activity; Lightning detection; Lightning performance; Lightning strikes; Monitoring periods; Multi-chamber; Lightning Multi chambers arresters were installed on 33kV bare overhead line in Malaysia to improve the line trippings due to lightning. In this pilot study, the line was equipped with line fault indicators and auto recloser for transient event recording. Field monitoring was carried out to determine feasibility and reliability of the device in preventing line trippings due to lightning. The case study line has been experiencing a significant amount of lightning activities, a total of 1,805 lightning strikes, detected by TNBR Lightning Detection System during 6 months monitoring period with an average peak current of 18.61 kA. Observation of one-time indicators has shown that 31 out of 180 devices have operated during the monitoring period. Line lightning performance analysis was carried out to quantify the effectiveness of the device in reducing tripping rate. � 2019 IEEE. Final 2023-05-29T07:25:20Z 2023-05-29T07:25:20Z 2019 Conference Paper 10.1109/APL.2019.8815993 2-s2.0-85072310898 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85072310898&doi=10.1109%2fAPL.2019.8815993&partnerID=40&md5=a3a0d8a4831ccb576504775c151f5284 https://irepository.uniten.edu.my/handle/123456789/24632 8815993 Institute of Electrical and Electronics Engineers Inc. Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description Overhead lines; Bare overhead lines; Distribution lines; Lightning activity; Lightning detection; Lightning performance; Lightning strikes; Monitoring periods; Multi-chamber; Lightning
author2 26422769600
author_facet 26422769600
Abdullah N.
Osman M.
Kadir M.Z.A.A.
Hatta N.M.
Ariffin M.F.
format Conference Paper
author Abdullah N.
Osman M.
Kadir M.Z.A.A.
Hatta N.M.
Ariffin M.F.
spellingShingle Abdullah N.
Osman M.
Kadir M.Z.A.A.
Hatta N.M.
Ariffin M.F.
Implementation and use of multi chamber arresters for 33kV overhead lines in Malaysia
author_sort Abdullah N.
title Implementation and use of multi chamber arresters for 33kV overhead lines in Malaysia
title_short Implementation and use of multi chamber arresters for 33kV overhead lines in Malaysia
title_full Implementation and use of multi chamber arresters for 33kV overhead lines in Malaysia
title_fullStr Implementation and use of multi chamber arresters for 33kV overhead lines in Malaysia
title_full_unstemmed Implementation and use of multi chamber arresters for 33kV overhead lines in Malaysia
title_sort implementation and use of multi chamber arresters for 33kv overhead lines in malaysia
publisher Institute of Electrical and Electronics Engineers Inc.
publishDate 2023
_version_ 1806423425370030080
score 13.223943