Implementation and use of multi chamber arresters for 33kV overhead lines in Malaysia
Overhead lines; Bare overhead lines; Distribution lines; Lightning activity; Lightning detection; Lightning performance; Lightning strikes; Monitoring periods; Multi-chamber; Lightning
Saved in:
Main Authors: | , , , , |
---|---|
Other Authors: | |
Format: | Conference Paper |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-24632 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-246322023-05-29T15:25:20Z Implementation and use of multi chamber arresters for 33kV overhead lines in Malaysia Abdullah N. Osman M. Kadir M.Z.A.A. Hatta N.M. Ariffin M.F. 26422769600 7201930315 25947297000 55611430000 35178958300 Overhead lines; Bare overhead lines; Distribution lines; Lightning activity; Lightning detection; Lightning performance; Lightning strikes; Monitoring periods; Multi-chamber; Lightning Multi chambers arresters were installed on 33kV bare overhead line in Malaysia to improve the line trippings due to lightning. In this pilot study, the line was equipped with line fault indicators and auto recloser for transient event recording. Field monitoring was carried out to determine feasibility and reliability of the device in preventing line trippings due to lightning. The case study line has been experiencing a significant amount of lightning activities, a total of 1,805 lightning strikes, detected by TNBR Lightning Detection System during 6 months monitoring period with an average peak current of 18.61 kA. Observation of one-time indicators has shown that 31 out of 180 devices have operated during the monitoring period. Line lightning performance analysis was carried out to quantify the effectiveness of the device in reducing tripping rate. � 2019 IEEE. Final 2023-05-29T07:25:20Z 2023-05-29T07:25:20Z 2019 Conference Paper 10.1109/APL.2019.8815993 2-s2.0-85072310898 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85072310898&doi=10.1109%2fAPL.2019.8815993&partnerID=40&md5=a3a0d8a4831ccb576504775c151f5284 https://irepository.uniten.edu.my/handle/123456789/24632 8815993 Institute of Electrical and Electronics Engineers Inc. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Overhead lines; Bare overhead lines; Distribution lines; Lightning activity; Lightning detection; Lightning performance; Lightning strikes; Monitoring periods; Multi-chamber; Lightning |
author2 |
26422769600 |
author_facet |
26422769600 Abdullah N. Osman M. Kadir M.Z.A.A. Hatta N.M. Ariffin M.F. |
format |
Conference Paper |
author |
Abdullah N. Osman M. Kadir M.Z.A.A. Hatta N.M. Ariffin M.F. |
spellingShingle |
Abdullah N. Osman M. Kadir M.Z.A.A. Hatta N.M. Ariffin M.F. Implementation and use of multi chamber arresters for 33kV overhead lines in Malaysia |
author_sort |
Abdullah N. |
title |
Implementation and use of multi chamber arresters for 33kV overhead lines in Malaysia |
title_short |
Implementation and use of multi chamber arresters for 33kV overhead lines in Malaysia |
title_full |
Implementation and use of multi chamber arresters for 33kV overhead lines in Malaysia |
title_fullStr |
Implementation and use of multi chamber arresters for 33kV overhead lines in Malaysia |
title_full_unstemmed |
Implementation and use of multi chamber arresters for 33kV overhead lines in Malaysia |
title_sort |
implementation and use of multi chamber arresters for 33kv overhead lines in malaysia |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2023 |
_version_ |
1806423425370030080 |
score |