Optimization of the direct buried characteristics for 11kV underground cable installation
Energy utilization; Telecommunication cables; Underground cables; Cable ampacity; Cable installations; Direct Buried; Installation methods; Insulation materials; Operational lifetime; Underground cable systems; Underground power cable system; Cables
Saved in:
Main Authors: | , , |
---|---|
Other Authors: | |
Format: | Conference Paper |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-23183 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-231832023-05-29T14:38:15Z Optimization of the direct buried characteristics for 11kV underground cable installation Raveendran S.K. Arokiam D. Thevadass M. 57064141200 57194948358 57194945027 Energy utilization; Telecommunication cables; Underground cables; Cable ampacity; Cable installations; Direct Buried; Installation methods; Insulation materials; Operational lifetime; Underground cable systems; Underground power cable system; Cables Direct buried is the most common and widely used installation method for underground power cable system. However, the installation characteristics that have been used in recent times do not have an optimum level of cable ampacity which could not support the increasing demand of electrical energy utilization. Besides, the existing installation characteristics have deteriorated the operational lifetime of the cables and in many cases have led to cable failure. Therefore, this projects aims to optimize the installation characteristics for underground cable system. The new optimized installation characteristics will ensure that the 11kV underground cable system is able to transmit electricity with an optimum cable ampacity. Throughout this project, CYMCAP software have been used to model and simulate the installation configuration based on the entered parameters in order to calculate the cable ampacity. The objective of this project have been achieved by recommending two new installation characteristics for the 11kV underground cable that can deliver an optimum cable ampacity. The two new optimized installation characteristics are firstly in changing the insulation material and secondly in changing the backfilling material. Hence, by using these two new optimized installation characteristics, the 11kV underground cable will be able to transmit electricity at higher ampacity and also increase the operational lifetime of the power cable whilst minimizing the occurrence of cable fault. � 2016 IEEE. Final 2023-05-29T06:38:15Z 2023-05-29T06:38:15Z 2017 Conference Paper 10.1109/PECON.2016.7951570 2-s2.0-85024389234 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85024389234&doi=10.1109%2fPECON.2016.7951570&partnerID=40&md5=ca3471abf02190b521881d2b1e78b062 https://irepository.uniten.edu.my/handle/123456789/23183 7951570 262 267 Institute of Electrical and Electronics Engineers Inc. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Energy utilization; Telecommunication cables; Underground cables; Cable ampacity; Cable installations; Direct Buried; Installation methods; Insulation materials; Operational lifetime; Underground cable systems; Underground power cable system; Cables |
author2 |
57064141200 |
author_facet |
57064141200 Raveendran S.K. Arokiam D. Thevadass M. |
format |
Conference Paper |
author |
Raveendran S.K. Arokiam D. Thevadass M. |
spellingShingle |
Raveendran S.K. Arokiam D. Thevadass M. Optimization of the direct buried characteristics for 11kV underground cable installation |
author_sort |
Raveendran S.K. |
title |
Optimization of the direct buried characteristics for 11kV underground cable installation |
title_short |
Optimization of the direct buried characteristics for 11kV underground cable installation |
title_full |
Optimization of the direct buried characteristics for 11kV underground cable installation |
title_fullStr |
Optimization of the direct buried characteristics for 11kV underground cable installation |
title_full_unstemmed |
Optimization of the direct buried characteristics for 11kV underground cable installation |
title_sort |
optimization of the direct buried characteristics for 11kv underground cable installation |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2023 |
_version_ |
1806424392456994816 |
score |
13.222552 |