Behaviour of Cold Formed Steel Built-Up Channel Columns Strengthened Using CFRP
This paper presents experimental findings of carbon fibre reinforced polymer (CFRP) strengthened cold-formed steel built-up channels subjected to axial load. In order to sensitively detect the buckling strengths and failure modes, twenty-four built-up columns were tested in which twelve columns were...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
2020
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-13319 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-133192020-03-16T08:18:38Z Behaviour of Cold Formed Steel Built-Up Channel Columns Strengthened Using CFRP Naganathan, S. Chakravarthy, H.G.N. Anuar, N.A. Kalavagunta, S. Mustapha, K.N.B. This paper presents experimental findings of carbon fibre reinforced polymer (CFRP) strengthened cold-formed steel built-up channels subjected to axial load. In order to sensitively detect the buckling strengths and failure modes, twenty-four built-up columns were tested in which twelve columns were unadorned and another twelve columns were strengthened using CFRP sheets. The columns were tested for ultimate load, lateral displacement and failure modes. Tension coupon tests were conducted to determine the material properties of test specimens. The experimental results were compared with the design load calculated according to AISI S100-16 specification and are found to be in good agreement. It is established that the use of CFRP for strengthening increases the ultimate load and delays the buckling. © 2019, Korean Society of Steel Construction. 2020-02-03T03:31:48Z 2020-02-03T03:31:48Z 2019 Article 10.1007/s13296-019-00293-5 en |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
language |
English |
description |
This paper presents experimental findings of carbon fibre reinforced polymer (CFRP) strengthened cold-formed steel built-up channels subjected to axial load. In order to sensitively detect the buckling strengths and failure modes, twenty-four built-up columns were tested in which twelve columns were unadorned and another twelve columns were strengthened using CFRP sheets. The columns were tested for ultimate load, lateral displacement and failure modes. Tension coupon tests were conducted to determine the material properties of test specimens. The experimental results were compared with the design load calculated according to AISI S100-16 specification and are found to be in good agreement. It is established that the use of CFRP for strengthening increases the ultimate load and delays the buckling. © 2019, Korean Society of Steel Construction. |
format |
Article |
author |
Naganathan, S. Chakravarthy, H.G.N. Anuar, N.A. Kalavagunta, S. Mustapha, K.N.B. |
spellingShingle |
Naganathan, S. Chakravarthy, H.G.N. Anuar, N.A. Kalavagunta, S. Mustapha, K.N.B. Behaviour of Cold Formed Steel Built-Up Channel Columns Strengthened Using CFRP |
author_facet |
Naganathan, S. Chakravarthy, H.G.N. Anuar, N.A. Kalavagunta, S. Mustapha, K.N.B. |
author_sort |
Naganathan, S. |
title |
Behaviour of Cold Formed Steel Built-Up Channel Columns Strengthened Using CFRP |
title_short |
Behaviour of Cold Formed Steel Built-Up Channel Columns Strengthened Using CFRP |
title_full |
Behaviour of Cold Formed Steel Built-Up Channel Columns Strengthened Using CFRP |
title_fullStr |
Behaviour of Cold Formed Steel Built-Up Channel Columns Strengthened Using CFRP |
title_full_unstemmed |
Behaviour of Cold Formed Steel Built-Up Channel Columns Strengthened Using CFRP |
title_sort |
behaviour of cold formed steel built-up channel columns strengthened using cfrp |
publishDate |
2020 |
_version_ |
1662758845705879552 |
score |
13.222552 |