Investigation of distributed generation units placement and sizing based on voltage stability condition indicator (VSCI)

Voltage instability in power distribution systems can result in voltage collapse throughout the grid. Today, with the advanced of power generation technology from renewable sources, concerns of utility companies are much being focused on the stability of the grid when there is an integration of dist...

Full description

Saved in:
Bibliographic Details
Main Authors: Raj, A., Ab Aziz, N.F., Yasin, Z.M., Salim, N.A.
Format: Article
Language:English
Published: 2020
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-12859
record_format dspace
spelling my.uniten.dspace-128592020-02-06T08:20:55Z Investigation of distributed generation units placement and sizing based on voltage stability condition indicator (VSCI) Raj, A. Ab Aziz, N.F. Yasin, Z.M. Salim, N.A. Voltage instability in power distribution systems can result in voltage collapse throughout the grid. Today, with the advanced of power generation technology from renewable sources, concerns of utility companies are much being focused on the stability of the grid when there is an integration of distributed generation (DG) in the system. This paper presents a study on DG units’ placement and sizing in a radial distribution network by using a pre-developed index called Voltage Stability Condition Index (VSCI). In this paper, VSCI is used to determine DG placement candidates, while the value of power losses is used to identify the best DG placement. The proposed method is tested on a standard 33-bus radial distribution network and compared with existing Ettehadi and Aman methods. The effectiveness of the method is presented in terms of reduction in power system losses, maximization of system loadability and voltage quality improvement. Results show that VSCI can be utilized as the voltage stability indicator for DG placement in radial distribution power system. The integration of DG is found to improve voltage stability by increasing the system loadability and reducing the power losses of the network. © 2019 Institute of Advanced Engineering and Science. All rights reserved. 2020-02-03T03:27:20Z 2020-02-03T03:27:20Z 2019 Article 10.11591/ijpeds.v10.i3.1317-1323 en
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
language English
description Voltage instability in power distribution systems can result in voltage collapse throughout the grid. Today, with the advanced of power generation technology from renewable sources, concerns of utility companies are much being focused on the stability of the grid when there is an integration of distributed generation (DG) in the system. This paper presents a study on DG units’ placement and sizing in a radial distribution network by using a pre-developed index called Voltage Stability Condition Index (VSCI). In this paper, VSCI is used to determine DG placement candidates, while the value of power losses is used to identify the best DG placement. The proposed method is tested on a standard 33-bus radial distribution network and compared with existing Ettehadi and Aman methods. The effectiveness of the method is presented in terms of reduction in power system losses, maximization of system loadability and voltage quality improvement. Results show that VSCI can be utilized as the voltage stability indicator for DG placement in radial distribution power system. The integration of DG is found to improve voltage stability by increasing the system loadability and reducing the power losses of the network. © 2019 Institute of Advanced Engineering and Science. All rights reserved.
format Article
author Raj, A.
Ab Aziz, N.F.
Yasin, Z.M.
Salim, N.A.
spellingShingle Raj, A.
Ab Aziz, N.F.
Yasin, Z.M.
Salim, N.A.
Investigation of distributed generation units placement and sizing based on voltage stability condition indicator (VSCI)
author_facet Raj, A.
Ab Aziz, N.F.
Yasin, Z.M.
Salim, N.A.
author_sort Raj, A.
title Investigation of distributed generation units placement and sizing based on voltage stability condition indicator (VSCI)
title_short Investigation of distributed generation units placement and sizing based on voltage stability condition indicator (VSCI)
title_full Investigation of distributed generation units placement and sizing based on voltage stability condition indicator (VSCI)
title_fullStr Investigation of distributed generation units placement and sizing based on voltage stability condition indicator (VSCI)
title_full_unstemmed Investigation of distributed generation units placement and sizing based on voltage stability condition indicator (VSCI)
title_sort investigation of distributed generation units placement and sizing based on voltage stability condition indicator (vsci)
publishDate 2020
_version_ 1662758780088090624
score 13.211869