Evaluation of transient response of different earthing configurations due to lightning impulses

Earthing system is very important in order to protect the electrical equipment as well as the human’s safety against over voltages. The main function of the earthling system is to remove unwanted excessive electrical currents caused by unusual conditions such as fault and lightning or switching over...

Full description

Saved in:
Bibliographic Details
Main Authors: Wai, L.M., Abd Rahman, M.S., Mohd Ariffin, A., Nik Ali, N.H., Osman, M., Ab Kadir, M.Z.A.
Format: Conference Proceeding
Language:English
Published: 2020
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-12780
record_format dspace
spelling my.uniten.dspace-127802020-08-19T06:03:51Z Evaluation of transient response of different earthing configurations due to lightning impulses Wai, L.M. Abd Rahman, M.S. Mohd Ariffin, A. Nik Ali, N.H. Osman, M. Ab Kadir, M.Z.A. Earthing system is very important in order to protect the electrical equipment as well as the human’s safety against over voltages. The main function of the earthling system is to remove unwanted excessive electrical currents caused by unusual conditions such as fault and lightning or switching over voltages by providing a low resistance path to the earth. Researchers had studied the behaviour of the earthling system to improve its performance for the past few years. There are few factors that influence the performance of the earthling system such as soil resistivity and soil ionization which need to be focused in order to improve the earthling. Thus, this paper evaluates on the factors that affect the behaviour of the earthling system based on simulation works using MATLAB and Safe Grid Software. Some analytical calculations are used to obtain the soil resistivity and resistance as well as the touch and step voltages. The simulation results were validated based on comparison with other studies on the factors that influence the earthling system performance. The results reveal that the variation of soil resistivity, the configuration of electrodes, current magnitude and frequency dependence can result in a change of transient response of the systems. © BEIESP. 2020-02-03T03:26:44Z 2020-02-03T03:26:44Z 2019-07 Conference Proceeding 10.35940/ijrte.D5118.118419 en 5th International Conference on Energy and Environment 2019 (Icee),
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
language English
description Earthing system is very important in order to protect the electrical equipment as well as the human’s safety against over voltages. The main function of the earthling system is to remove unwanted excessive electrical currents caused by unusual conditions such as fault and lightning or switching over voltages by providing a low resistance path to the earth. Researchers had studied the behaviour of the earthling system to improve its performance for the past few years. There are few factors that influence the performance of the earthling system such as soil resistivity and soil ionization which need to be focused in order to improve the earthling. Thus, this paper evaluates on the factors that affect the behaviour of the earthling system based on simulation works using MATLAB and Safe Grid Software. Some analytical calculations are used to obtain the soil resistivity and resistance as well as the touch and step voltages. The simulation results were validated based on comparison with other studies on the factors that influence the earthling system performance. The results reveal that the variation of soil resistivity, the configuration of electrodes, current magnitude and frequency dependence can result in a change of transient response of the systems. © BEIESP.
format Conference Proceeding
author Wai, L.M.
Abd Rahman, M.S.
Mohd Ariffin, A.
Nik Ali, N.H.
Osman, M.
Ab Kadir, M.Z.A.
spellingShingle Wai, L.M.
Abd Rahman, M.S.
Mohd Ariffin, A.
Nik Ali, N.H.
Osman, M.
Ab Kadir, M.Z.A.
Evaluation of transient response of different earthing configurations due to lightning impulses
author_facet Wai, L.M.
Abd Rahman, M.S.
Mohd Ariffin, A.
Nik Ali, N.H.
Osman, M.
Ab Kadir, M.Z.A.
author_sort Wai, L.M.
title Evaluation of transient response of different earthing configurations due to lightning impulses
title_short Evaluation of transient response of different earthing configurations due to lightning impulses
title_full Evaluation of transient response of different earthing configurations due to lightning impulses
title_fullStr Evaluation of transient response of different earthing configurations due to lightning impulses
title_full_unstemmed Evaluation of transient response of different earthing configurations due to lightning impulses
title_sort evaluation of transient response of different earthing configurations due to lightning impulses
publishDate 2020
_version_ 1678595884856639488
score 13.222552