Energy usage monitoring system
Electrical energy price has been increa sing over the years. Due to this reason, home users are getting more concern about the efficiency of the electrical appliances . The solution on this problem is to create an energy usage monitoring system that can mon...
Saved in:
Main Author: | |
---|---|
Format: | Final Year Project Report |
Language: | English English |
Published: |
Universiti Malaysia Sarawak, UNIMAS
2009
|
Subjects: | |
Online Access: | http://ir.unimas.my/id/eprint/6514/1/ENERGY%20USAGE%20MONITORING%20SYSTEM%2824%20pgs%29.pdf http://ir.unimas.my/id/eprint/6514/8/ENERGY%20USAGE%20MONITORING%20SYSTEM%28OCR%29.pdf http://ir.unimas.my/id/eprint/6514/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimas.ir.6514 |
---|---|
record_format |
eprints |
spelling |
my.unimas.ir.65142023-02-08T02:28:55Z http://ir.unimas.my/id/eprint/6514/ Energy usage monitoring system Chong, Kian Tat T Technology (General) TK Electrical engineering. Electronics Nuclear engineering Electrical energy price has been increa sing over the years. Due to this reason, home users are getting more concern about the efficiency of the electrical appliances . The solution on this problem is to create an energy usage monitoring system that can monitor the energy used by electrical appliances . The objective of this project is to design and build a computer based energy monitoring system. The system will be consisting of a compu ter, a data acquisition (DAQ) module , a voltage sensor and a current sensor. The LabVIEW graphical programming software by National Instrument Inc. is used to design and build the computer interfacing software (virtual instrument software) . Th e system is a ble to measure the source frequency, source voltage, current drown by the monitored device, real power, apparent power, power factor, phase shift between the voltage graph and the current graph (in both radiance and degree), kilo - Watt - hour reading, monito red device operation time (elapsed time) and cost of operation of the monitored device. The measured data is presented in both graphical and numerical form. The system also has error detection capability (over voltage, voltage too low and over current dete ction) which will cut off the power supply when error is detected. The database of the system is able to store both measurement data and error report. This system can be accessed remotely by using the Windows Remote Desktop Connection software. Universiti Malaysia Sarawak, UNIMAS 2009 Final Year Project Report NonPeerReviewed text en http://ir.unimas.my/id/eprint/6514/1/ENERGY%20USAGE%20MONITORING%20SYSTEM%2824%20pgs%29.pdf text en http://ir.unimas.my/id/eprint/6514/8/ENERGY%20USAGE%20MONITORING%20SYSTEM%28OCR%29.pdf Chong, Kian Tat (2009) Energy usage monitoring system. [Final Year Project Report] (Unpublished) |
institution |
Universiti Malaysia Sarawak |
building |
Centre for Academic Information Services (CAIS) |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Sarawak |
content_source |
UNIMAS Institutional Repository |
url_provider |
http://ir.unimas.my/ |
language |
English English |
topic |
T Technology (General) TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
T Technology (General) TK Electrical engineering. Electronics Nuclear engineering Chong, Kian Tat Energy usage monitoring system |
description |
Electrical energy price has been increa
sing over the years. Due to this
reason,
home
users are getting more concern about the efficiency of the
electrical appliances
.
The solution
on
this problem is to create an energy usage monitoring system that can
monitor the energy used
by
electrical appliances
. The objective of this project is to
design and build a computer based energy monitoring system.
The system will be
consisting
of a compu
ter,
a data acquisition (DAQ)
module
, a voltage sensor and a
current sensor.
The LabVIEW graphical programming software by National Instrument
Inc. is used to design and build the computer interfacing software (virtual instrument
software)
.
Th
e system is a
ble to measure the source frequency, source voltage, current
drown by the monitored device, real power, apparent power, power factor, phase shift
between the voltage graph and the current graph (in both radiance and degree), kilo
-
Watt
-
hour reading, monito
red device operation time (elapsed time) and cost of operation
of the monitored device. The measured data
is
presented in both graphical and numerical
form. The system also has error detection capability (over voltage, voltage too low and
over current dete
ction) which will cut off the power supply when error is detected. The
database of the system is able to store both measurement data
and error report. This
system can be accessed remotely
by using the Windows Remote Desktop Connection
software. |
format |
Final Year Project Report |
author |
Chong, Kian Tat |
author_facet |
Chong, Kian Tat |
author_sort |
Chong, Kian Tat |
title |
Energy usage monitoring system |
title_short |
Energy usage monitoring system |
title_full |
Energy usage monitoring system |
title_fullStr |
Energy usage monitoring system |
title_full_unstemmed |
Energy usage monitoring system |
title_sort |
energy usage monitoring system |
publisher |
Universiti Malaysia Sarawak, UNIMAS |
publishDate |
2009 |
url |
http://ir.unimas.my/id/eprint/6514/1/ENERGY%20USAGE%20MONITORING%20SYSTEM%2824%20pgs%29.pdf http://ir.unimas.my/id/eprint/6514/8/ENERGY%20USAGE%20MONITORING%20SYSTEM%28OCR%29.pdf http://ir.unimas.my/id/eprint/6514/ |
_version_ |
1758582474262183936 |
score |
13.211869 |