SMART METERING AS SMART ELECTRIC ENERGY MANAGEMENT

Increase of consumption of electricity due to this High-Tech Era, energy saving become very important as power generation still highly depending on non-renewable energy. The only electricity usage measurement tool installed in everyone house which is electric meter only capable of displaying c...

Full description

Saved in:
Bibliographic Details
Main Author: Chin Jing Heng, -
Format: Final Year Project Report
Language:English
Published: Universiti Malaysia Sarawak 2022
Subjects:
Online Access:http://ir.unimas.my/id/eprint/39456/3/Chin%20Jing%20Heng%20-%20fulltext.pdf
http://ir.unimas.my/id/eprint/39456/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimas.ir.39456
record_format eprints
spelling my.unimas.ir.394562024-01-02T07:52:50Z http://ir.unimas.my/id/eprint/39456/ SMART METERING AS SMART ELECTRIC ENERGY MANAGEMENT Chin Jing Heng, - TK Electrical engineering. Electronics Nuclear engineering Increase of consumption of electricity due to this High-Tech Era, energy saving become very important as power generation still highly depending on non-renewable energy. The only electricity usage measurement tool installed in everyone house which is electric meter only capable of displaying cumulative energy consumption. This conventional type of electric meter causes people clueless about their electricity consumption as it is difficult to track and determine which electrical appliances contribute to that amount of electricity consumption. Therefore, in this project Smart Electric Meter System (SEMS) is designed to ease the process of monitoring the power consumption of electrical appliances and manage their appliances. The SEMS consists of Smart Electric Meter (SEM) that monitor the electricity usage of all the load at home and Smart Electric Plug (SEP) to monitor single electrical appliances. The main component of this project is components that are widely available in market such as ESP 8266, PZEM004T, Real Time Clock Module DS3231, Solid-state Relay, and OLED display. In this project, experiment is done by using incandescent bulb and ballast as load to test the accuracy of voltage and current measurement of SEM and SEP by comparing it to Flukes 317 True RMS Clamp Meter. The error for voltage measurement of SEM is ranging between 0.177%-0.279% and error for current measurement is ranging from 4.274% to 6.279%. For SEP the error of voltage measurement is between 0.045% and 0.124% while error of current measurement is between 4.167% and 7.477%. The SEP in this project also provide energy management feature which been tested in this research that it is capable of saving 57.35% of electricity and 45.86% of cost for electricity when compared to load that connected to a normal power plug. Universiti Malaysia Sarawak 2022 Final Year Project Report NonPeerReviewed text en http://ir.unimas.my/id/eprint/39456/3/Chin%20Jing%20Heng%20-%20fulltext.pdf Chin Jing Heng, - (2022) SMART METERING AS SMART ELECTRIC ENERGY MANAGEMENT. [Final Year Project Report] (Unpublished)
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Chin Jing Heng, -
SMART METERING AS SMART ELECTRIC ENERGY MANAGEMENT
description Increase of consumption of electricity due to this High-Tech Era, energy saving become very important as power generation still highly depending on non-renewable energy. The only electricity usage measurement tool installed in everyone house which is electric meter only capable of displaying cumulative energy consumption. This conventional type of electric meter causes people clueless about their electricity consumption as it is difficult to track and determine which electrical appliances contribute to that amount of electricity consumption. Therefore, in this project Smart Electric Meter System (SEMS) is designed to ease the process of monitoring the power consumption of electrical appliances and manage their appliances. The SEMS consists of Smart Electric Meter (SEM) that monitor the electricity usage of all the load at home and Smart Electric Plug (SEP) to monitor single electrical appliances. The main component of this project is components that are widely available in market such as ESP 8266, PZEM004T, Real Time Clock Module DS3231, Solid-state Relay, and OLED display. In this project, experiment is done by using incandescent bulb and ballast as load to test the accuracy of voltage and current measurement of SEM and SEP by comparing it to Flukes 317 True RMS Clamp Meter. The error for voltage measurement of SEM is ranging between 0.177%-0.279% and error for current measurement is ranging from 4.274% to 6.279%. For SEP the error of voltage measurement is between 0.045% and 0.124% while error of current measurement is between 4.167% and 7.477%. The SEP in this project also provide energy management feature which been tested in this research that it is capable of saving 57.35% of electricity and 45.86% of cost for electricity when compared to load that connected to a normal power plug.
format Final Year Project Report
author Chin Jing Heng, -
author_facet Chin Jing Heng, -
author_sort Chin Jing Heng, -
title SMART METERING AS SMART ELECTRIC ENERGY MANAGEMENT
title_short SMART METERING AS SMART ELECTRIC ENERGY MANAGEMENT
title_full SMART METERING AS SMART ELECTRIC ENERGY MANAGEMENT
title_fullStr SMART METERING AS SMART ELECTRIC ENERGY MANAGEMENT
title_full_unstemmed SMART METERING AS SMART ELECTRIC ENERGY MANAGEMENT
title_sort smart metering as smart electric energy management
publisher Universiti Malaysia Sarawak
publishDate 2022
url http://ir.unimas.my/id/eprint/39456/3/Chin%20Jing%20Heng%20-%20fulltext.pdf
http://ir.unimas.my/id/eprint/39456/
_version_ 1787140510350049280
score 13.211869