Classification of Potential Risk Factors through HIRARC Method in Assessing Indoor Environment of Museums

Museums were established in Malaysia more than a hundred years ago. Since the year 2005, Malaysian government has discouraged constructing new purposely built museums in favour of refurbishing historic and old buildings to function as adaptive reused museums. Commonly due to insufficient ventilation...

Full description

Saved in:
Bibliographic Details
Main Authors: Syahrun Neizam, Mohd Dzulkifli, Abd Halid, Abdullah, Lee, Yee Yong, Mohd Mahathir, Suhaimi Shamsuri, Zawawi, Daud
Format: Article
Language:English
Published: Penerbit UTHM 2018
Subjects:
Online Access:http://ir.unimas.my/id/eprint/22984/1/Classification%20of%20Potential%20Risk%20Factors%20through%20HIRARC%20Method%20in%20Assessing%20Indoor%20Environment%20of%20Museums%20%20-%20Copy.pdf
http://ir.unimas.my/id/eprint/22984/
http://penerbit.uthm.edu.my/ojs/index.php/ijie
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimas.ir.22984
record_format eprints
spelling my.unimas.ir.229842023-05-15T07:36:46Z http://ir.unimas.my/id/eprint/22984/ Classification of Potential Risk Factors through HIRARC Method in Assessing Indoor Environment of Museums Syahrun Neizam, Mohd Dzulkifli Abd Halid, Abdullah Lee, Yee Yong Mohd Mahathir, Suhaimi Shamsuri Zawawi, Daud T Technology (General) TA Engineering (General). Civil engineering (General) Museums were established in Malaysia more than a hundred years ago. Since the year 2005, Malaysian government has discouraged constructing new purposely built museums in favour of refurbishing historic and old buildings to function as adaptive reused museums. Commonly due to insufficient ventilation, fully mechanically ventilated museums can pose critical indoor environmental issues that may lead to health hazards and risks among employees and visitors. Thus, the purpose of this study is to determine the potential risk factors within the museums based on indoor environmental criteria. This potential risk factors are resulted from the ‘Potential Risk Categories’, which have been developed by adopting the established Hazard Identification, Risks Assessment and Risk Control (HIRARC) Method. Based on the assessment of four main indoor environmental criteria in the Potential Risk Categories, it was discovered that 8 out of 24 museums are in the range of medium potential risk, while the rest of them are in the range of low potential risk. The ‘Potential Risk Categories’ is important for assessing indoor environment at the museums whereby the most critical risk could be assessed, and then suggestion could be provided to minimize the potential risk within the spaces inside the museums. Penerbit UTHM 2018 Article PeerReviewed text en http://ir.unimas.my/id/eprint/22984/1/Classification%20of%20Potential%20Risk%20Factors%20through%20HIRARC%20Method%20in%20Assessing%20Indoor%20Environment%20of%20Museums%20%20-%20Copy.pdf Syahrun Neizam, Mohd Dzulkifli and Abd Halid, Abdullah and Lee, Yee Yong and Mohd Mahathir, Suhaimi Shamsuri and Zawawi, Daud (2018) Classification of Potential Risk Factors through HIRARC Method in Assessing Indoor Environment of Museums. International Journal of Integrated Engineering, 10 (8). pp. 43-55. ISSN 2600-7916 http://penerbit.uthm.edu.my/ojs/index.php/ijie DOI: https://doi.org/10.30880/ijie
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
topic T Technology (General)
TA Engineering (General). Civil engineering (General)
spellingShingle T Technology (General)
TA Engineering (General). Civil engineering (General)
Syahrun Neizam, Mohd Dzulkifli
Abd Halid, Abdullah
Lee, Yee Yong
Mohd Mahathir, Suhaimi Shamsuri
Zawawi, Daud
Classification of Potential Risk Factors through HIRARC Method in Assessing Indoor Environment of Museums
description Museums were established in Malaysia more than a hundred years ago. Since the year 2005, Malaysian government has discouraged constructing new purposely built museums in favour of refurbishing historic and old buildings to function as adaptive reused museums. Commonly due to insufficient ventilation, fully mechanically ventilated museums can pose critical indoor environmental issues that may lead to health hazards and risks among employees and visitors. Thus, the purpose of this study is to determine the potential risk factors within the museums based on indoor environmental criteria. This potential risk factors are resulted from the ‘Potential Risk Categories’, which have been developed by adopting the established Hazard Identification, Risks Assessment and Risk Control (HIRARC) Method. Based on the assessment of four main indoor environmental criteria in the Potential Risk Categories, it was discovered that 8 out of 24 museums are in the range of medium potential risk, while the rest of them are in the range of low potential risk. The ‘Potential Risk Categories’ is important for assessing indoor environment at the museums whereby the most critical risk could be assessed, and then suggestion could be provided to minimize the potential risk within the spaces inside the museums.
format Article
author Syahrun Neizam, Mohd Dzulkifli
Abd Halid, Abdullah
Lee, Yee Yong
Mohd Mahathir, Suhaimi Shamsuri
Zawawi, Daud
author_facet Syahrun Neizam, Mohd Dzulkifli
Abd Halid, Abdullah
Lee, Yee Yong
Mohd Mahathir, Suhaimi Shamsuri
Zawawi, Daud
author_sort Syahrun Neizam, Mohd Dzulkifli
title Classification of Potential Risk Factors through HIRARC Method in Assessing Indoor Environment of Museums
title_short Classification of Potential Risk Factors through HIRARC Method in Assessing Indoor Environment of Museums
title_full Classification of Potential Risk Factors through HIRARC Method in Assessing Indoor Environment of Museums
title_fullStr Classification of Potential Risk Factors through HIRARC Method in Assessing Indoor Environment of Museums
title_full_unstemmed Classification of Potential Risk Factors through HIRARC Method in Assessing Indoor Environment of Museums
title_sort classification of potential risk factors through hirarc method in assessing indoor environment of museums
publisher Penerbit UTHM
publishDate 2018
url http://ir.unimas.my/id/eprint/22984/1/Classification%20of%20Potential%20Risk%20Factors%20through%20HIRARC%20Method%20in%20Assessing%20Indoor%20Environment%20of%20Museums%20%20-%20Copy.pdf
http://ir.unimas.my/id/eprint/22984/
http://penerbit.uthm.edu.my/ojs/index.php/ijie
_version_ 1767209820838952960
score 13.211869