Preliminary investigation of developing most economical cooling system utilizing underground time-delay characteristics
MUCEET 2009 is organized by Malaysian Technical Universities Network (MTUN) comprising of Universiti Malaysia Perlis (UniMAP), Universiti Tun Hussein Onn (UTHM), Universiti Teknikal Melaka (UTeM) and Universiti Malaysia Pahang (UMP), 20th - 22nd June 2009 at M. S. Garden Hotel, Kuantan, Pahang.
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Working Paper |
Language: | English |
Published: |
Universiti Malaysia Pahang (UMP)
2010
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my/xmlui/handle/123456789/8541 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-8541 |
---|---|
record_format |
dspace |
spelling |
my.unimap-85412010-08-11T03:18:29Z Preliminary investigation of developing most economical cooling system utilizing underground time-delay characteristics Sivarao M. S., Kasim Sivasan N. I. S., Hussein A. R. M., Warikh A. S., Rahim Tajul, A. Taufik Cooling system Underground temperature MUCEET Malaysian Technical Universities Conference on Engineering and Technology MUCEET 2009 is organized by Malaysian Technical Universities Network (MTUN) comprising of Universiti Malaysia Perlis (UniMAP), Universiti Tun Hussein Onn (UTHM), Universiti Teknikal Melaka (UTeM) and Universiti Malaysia Pahang (UMP), 20th - 22nd June 2009 at M. S. Garden Hotel, Kuantan, Pahang. The preliminary research work conducted has produced satisfactory result, in which the system is being designed with an accumulator and chamber so that it can be used as the primary cooling system to save electricity consumption up to 70% as compared to the conventional cooling system available in our country. Therefore, an underground evacuation system with complete chamber and control system is to be developed to cater human cooling comfort zone. To make this underground cooling evacuation function, an investigation on underground temperature of certain depth has been carried out extensively to provide valuable and most reliable data before any further related work is initialized. Through a very ‘tedious and expensive’ methodology, the temperature of five different depths has been traced and proves that the human comfort zone has been achieved. This paper shows the preliminary work subjected to the design of the novel cooling system to be. 2010-08-11T03:18:29Z 2010-08-11T03:18:29Z 2009-06-20 Working Paper p.115-117 http://hdl.handle.net/123456789/8541 en Proceedings of the Malaysian Technical Universities Conference on Engineering and Technology (MUCEET) 2009 Universiti Malaysia Pahang (UMP) |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Cooling system Underground temperature MUCEET Malaysian Technical Universities Conference on Engineering and Technology |
spellingShingle |
Cooling system Underground temperature MUCEET Malaysian Technical Universities Conference on Engineering and Technology Sivarao M. S., Kasim Sivasan N. I. S., Hussein A. R. M., Warikh A. S., Rahim Tajul, A. Taufik Preliminary investigation of developing most economical cooling system utilizing underground time-delay characteristics |
description |
MUCEET 2009 is organized by Malaysian Technical Universities Network (MTUN) comprising of Universiti Malaysia Perlis (UniMAP), Universiti Tun Hussein Onn (UTHM), Universiti Teknikal Melaka (UTeM) and Universiti Malaysia Pahang (UMP), 20th - 22nd June 2009 at M. S. Garden Hotel, Kuantan, Pahang. |
format |
Working Paper |
author |
Sivarao M. S., Kasim Sivasan N. I. S., Hussein A. R. M., Warikh A. S., Rahim Tajul, A. Taufik |
author_facet |
Sivarao M. S., Kasim Sivasan N. I. S., Hussein A. R. M., Warikh A. S., Rahim Tajul, A. Taufik |
author_sort |
Sivarao |
title |
Preliminary investigation of developing most economical cooling system utilizing underground time-delay characteristics |
title_short |
Preliminary investigation of developing most economical cooling system utilizing underground time-delay characteristics |
title_full |
Preliminary investigation of developing most economical cooling system utilizing underground time-delay characteristics |
title_fullStr |
Preliminary investigation of developing most economical cooling system utilizing underground time-delay characteristics |
title_full_unstemmed |
Preliminary investigation of developing most economical cooling system utilizing underground time-delay characteristics |
title_sort |
preliminary investigation of developing most economical cooling system utilizing underground time-delay characteristics |
publisher |
Universiti Malaysia Pahang (UMP) |
publishDate |
2010 |
url |
http://dspace.unimap.edu.my/xmlui/handle/123456789/8541 |
_version_ |
1643789256962867200 |
score |
13.222552 |