Single-Phase induction motor performance with Symmetrical AC supply
One source of distortion is represented by non-linear loads. When a pure fundamental voltage with zero source impedance is applied to a non linear load, the resulting current differs in shape from the applied voltage. The growing use of power electronic applications has increased the friction of non...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Learning Object |
Language: | English |
Published: |
Universiti Malaysia Perlis
2009
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my/xmlui/handle/123456789/4420 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-4420 |
---|---|
record_format |
dspace |
spelling |
my.unimap-44202009-02-20T09:28:19Z Single-Phase induction motor performance with Symmetrical AC supply Muhammad Sukri Ngatiman Syafruddin Hasan, Ir. (Advisor) Electrical engineering Electronic apparatus and appliances -- Power supply Electric motors, Induction Electric motors, Induction -- Design and construction AC voltage controller One source of distortion is represented by non-linear loads. When a pure fundamental voltage with zero source impedance is applied to a non linear load, the resulting current differs in shape from the applied voltage. The growing use of power electronic applications has increased the friction of non-sinusoidal currents and voltages in utility networks, drives equipments and building. If a thyristor switch is connected between ac supply and load, the power flow can be controlled by varying the rms value of AC voltage applied to the load; and this type of power circuit is known as an AC voltage controller. The most common applications of AC voltage controllers have increased the friction of non-sinusoidal currents and voltages in utility networks, drives equipments and building. In this project, the symmetrical AC voltage is found from the output of a symmetrical AC voltage controller, therefore, the output is not pure sinusoidal. For comparative need of single phase induction motor performance, the motor is the subjected to this output voltage, and also with pure sinusoidal input voltage. The performances are illustrated in term of speed of motor, harmonics, power factor and power consumption on input source side view. 2009-02-02T07:25:58Z 2009-02-02T07:25:58Z 2008-05 Learning Object http://hdl.handle.net/123456789/4420 en Universiti Malaysia Perlis School of Electrical Systems Engineering |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Electrical engineering Electronic apparatus and appliances -- Power supply Electric motors, Induction Electric motors, Induction -- Design and construction AC voltage controller |
spellingShingle |
Electrical engineering Electronic apparatus and appliances -- Power supply Electric motors, Induction Electric motors, Induction -- Design and construction AC voltage controller Muhammad Sukri Ngatiman Single-Phase induction motor performance with Symmetrical AC supply |
description |
One source of distortion is represented by non-linear loads. When a pure fundamental voltage with zero source impedance is applied to a non linear load, the resulting current differs in shape from the applied voltage. The growing use of power electronic applications has increased the friction of non-sinusoidal currents and voltages in utility networks, drives equipments and building. If a thyristor switch is connected between ac supply and load, the power flow can be controlled by varying the rms value of AC voltage applied to the load; and this type of power circuit is known as an AC voltage controller. The most common applications of AC voltage controllers have increased the friction of non-sinusoidal currents and voltages in utility networks, drives equipments and building. In this project, the symmetrical AC voltage is found from the output of a symmetrical AC voltage controller, therefore, the output is not pure sinusoidal. For comparative need of single phase induction motor performance, the motor is the subjected to this output voltage, and also with pure sinusoidal input voltage. The performances are illustrated in term of speed of motor, harmonics, power factor and power consumption on input source side view. |
author2 |
Syafruddin Hasan, Ir. (Advisor) |
author_facet |
Syafruddin Hasan, Ir. (Advisor) Muhammad Sukri Ngatiman |
format |
Learning Object |
author |
Muhammad Sukri Ngatiman |
author_sort |
Muhammad Sukri Ngatiman |
title |
Single-Phase induction motor performance with Symmetrical AC supply |
title_short |
Single-Phase induction motor performance with Symmetrical AC supply |
title_full |
Single-Phase induction motor performance with Symmetrical AC supply |
title_fullStr |
Single-Phase induction motor performance with Symmetrical AC supply |
title_full_unstemmed |
Single-Phase induction motor performance with Symmetrical AC supply |
title_sort |
single-phase induction motor performance with symmetrical ac supply |
publisher |
Universiti Malaysia Perlis |
publishDate |
2009 |
url |
http://dspace.unimap.edu.my/xmlui/handle/123456789/4420 |
_version_ |
1643788104506540032 |
score |
13.222552 |