Investigation of harmonic losses from compact fluorescent lamp due to type of voltage source
Access is limited to UniMAP community.
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Learning Object |
Language: | English |
Published: |
Universiti Malaysia Perlis (UniMAP)
2015
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my:80/xmlui/handle/123456789/40339 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-40339 |
---|---|
record_format |
dspace |
spelling |
my.unimap-403392015-07-24T08:09:26Z Investigation of harmonic losses from compact fluorescent lamp due to type of voltage source Nurhidayah, Anuar Ir. Risnidar Chan Bahaudin Harmonic losses Harmonic analysis Harmonics (Electric waves) Compact fluorescent lamp (CFL) Access is limited to UniMAP community. Project reportedly is focus on investigation of harmonic losses result from compact fluorescent lamp usage (CFL) by using a few unique voltage type, which is triangular wave, square wave, combination of third harmonic, fifth and seventh and sinusoidal wave as main referral. This project sees effect the input current form and the voltage after nonlinear burden (CFL) is connected. Criteria that observed are active power effect, reactive power, real power, power factor, and also the total harmonic distortion for current and voltage. CFL's nonlinear load had produced current distortion more to 100 percent on power system electric that harmful to amount of power received by end user. The measurement from the experiment been analyzed until the eleventh of harmonic seems precise with the experiment data. The sinusoidal and combination of third, fifth and seventh harmonic seem to be the better as a source voltage compared to the square wave. To design and simulate circuit, Simulink Matlab 2009 software been used. 2015-07-24T08:09:26Z 2015-07-24T08:09:26Z 2011-05 Learning Object http://dspace.unimap.edu.my:80/xmlui/handle/123456789/40339 en Universiti Malaysia Perlis (UniMAP) School of Electrical Systems Engineering |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Harmonic losses Harmonic analysis Harmonics (Electric waves) Compact fluorescent lamp (CFL) |
spellingShingle |
Harmonic losses Harmonic analysis Harmonics (Electric waves) Compact fluorescent lamp (CFL) Nurhidayah, Anuar Investigation of harmonic losses from compact fluorescent lamp due to type of voltage source |
description |
Access is limited to UniMAP community. |
author2 |
Ir. Risnidar Chan Bahaudin |
author_facet |
Ir. Risnidar Chan Bahaudin Nurhidayah, Anuar |
format |
Learning Object |
author |
Nurhidayah, Anuar |
author_sort |
Nurhidayah, Anuar |
title |
Investigation of harmonic losses from compact fluorescent lamp due to type of voltage source |
title_short |
Investigation of harmonic losses from compact fluorescent lamp due to type of voltage source |
title_full |
Investigation of harmonic losses from compact fluorescent lamp due to type of voltage source |
title_fullStr |
Investigation of harmonic losses from compact fluorescent lamp due to type of voltage source |
title_full_unstemmed |
Investigation of harmonic losses from compact fluorescent lamp due to type of voltage source |
title_sort |
investigation of harmonic losses from compact fluorescent lamp due to type of voltage source |
publisher |
Universiti Malaysia Perlis (UniMAP) |
publishDate |
2015 |
url |
http://dspace.unimap.edu.my:80/xmlui/handle/123456789/40339 |
_version_ |
1643799339005378560 |
score |
13.222552 |