Investigation of harmonic losses from compact fluorescent lamp due to type of voltage source

Access is limited to UniMAP community.

Saved in:
Bibliographic Details
Main Author: Nurhidayah, Anuar
Other Authors: Ir. Risnidar Chan Bahaudin
Format: Learning Object
Language:English
Published: Universiti Malaysia Perlis (UniMAP) 2015
Subjects:
Online Access:http://dspace.unimap.edu.my:80/xmlui/handle/123456789/40339
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimap-40339
record_format dspace
spelling my.unimap-403392015-07-24T08:09:26Z Investigation of harmonic losses from compact fluorescent lamp due to type of voltage source Nurhidayah, Anuar Ir. Risnidar Chan Bahaudin Harmonic losses Harmonic analysis Harmonics (Electric waves) Compact fluorescent lamp (CFL) Access is limited to UniMAP community. Project reportedly is focus on investigation of harmonic losses result from compact fluorescent lamp usage (CFL) by using a few unique voltage type, which is triangular wave, square wave, combination of third harmonic, fifth and seventh and sinusoidal wave as main referral. This project sees effect the input current form and the voltage after nonlinear burden (CFL) is connected. Criteria that observed are active power effect, reactive power, real power, power factor, and also the total harmonic distortion for current and voltage. CFL's nonlinear load had produced current distortion more to 100 percent on power system electric that harmful to amount of power received by end user. The measurement from the experiment been analyzed until the eleventh of harmonic seems precise with the experiment data. The sinusoidal and combination of third, fifth and seventh harmonic seem to be the better as a source voltage compared to the square wave. To design and simulate circuit, Simulink Matlab 2009 software been used. 2015-07-24T08:09:26Z 2015-07-24T08:09:26Z 2011-05 Learning Object http://dspace.unimap.edu.my:80/xmlui/handle/123456789/40339 en Universiti Malaysia Perlis (UniMAP) School of Electrical Systems Engineering
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Harmonic losses
Harmonic analysis
Harmonics (Electric waves)
Compact fluorescent lamp (CFL)
spellingShingle Harmonic losses
Harmonic analysis
Harmonics (Electric waves)
Compact fluorescent lamp (CFL)
Nurhidayah, Anuar
Investigation of harmonic losses from compact fluorescent lamp due to type of voltage source
description Access is limited to UniMAP community.
author2 Ir. Risnidar Chan Bahaudin
author_facet Ir. Risnidar Chan Bahaudin
Nurhidayah, Anuar
format Learning Object
author Nurhidayah, Anuar
author_sort Nurhidayah, Anuar
title Investigation of harmonic losses from compact fluorescent lamp due to type of voltage source
title_short Investigation of harmonic losses from compact fluorescent lamp due to type of voltage source
title_full Investigation of harmonic losses from compact fluorescent lamp due to type of voltage source
title_fullStr Investigation of harmonic losses from compact fluorescent lamp due to type of voltage source
title_full_unstemmed Investigation of harmonic losses from compact fluorescent lamp due to type of voltage source
title_sort investigation of harmonic losses from compact fluorescent lamp due to type of voltage source
publisher Universiti Malaysia Perlis (UniMAP)
publishDate 2015
url http://dspace.unimap.edu.my:80/xmlui/handle/123456789/40339
_version_ 1643799339005378560