Simulative study of two-phase homogenous and isotropic media imaging using magnetic induction tomography

Link to publisher's homepage at http://www.penerbit.utm.my/

Saved in:
Bibliographic Details
Main Authors: Zulkarnay, Zakaria, Ibrahim, Balkhis, Lee, Pick Yern, Nor Muzakkir, Nor Ayob, Mohd Hafiz, Fazalul Rahiman, Dr., Mohd Zikrillah, Zawahirah, Ruzairi, Abdul Rahim, Prof. Dr.
Other Authors: zulkarnay@unimap.edu.my
Format: Article
Language:English
Published: Penerbit UTM Press 2015
Subjects:
Online Access:http://dspace.unimap.edu.my:80/xmlui/handle/123456789/39949
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimap-39949
record_format dspace
spelling my.unimap-399492015-05-25T03:20:22Z Simulative study of two-phase homogenous and isotropic media imaging using magnetic induction tomography Zulkarnay, Zakaria Ibrahim, Balkhis Lee, Pick Yern Nor Muzakkir, Nor Ayob Mohd Hafiz, Fazalul Rahiman, Dr. Mohd Zikrillah, Zawahirah Ruzairi, Abdul Rahim, Prof. Dr. zulkarnay@unimap.edu.my Ibrahim_balkhis@gmail.com pickyern_88@yahoo.com normuzakkir@gmail.com hafiz@unimap.edu.my ruzairi@fke.utm.my Image reconstruction algorithm Isotropic Low conductivity Magnetic induction Tomography Link to publisher's homepage at http://www.penerbit.utm.my/ Magnetic induction tomography is a new non-invasive technology, based on eddy current discovery of electromagnetic induction by Michael Faraday. Through this technique, the passive electrical properties distribution of an object can be obtained by the use of image reconstruction algorithm implemented in this system. There are many types of image reconstruction that have been developed for this modality, however in this paper only two algorithms discussed, Linear Back Projection and Eminent Pixel Reconstruction. Linear Back Projection algorithm is the most basic type of image reconstruction. It is the simplest and fast algorithm out of all types of algorithms, whereas Eminent Pixel Reconstruction algorithm is an improved algorithm which provided better images and has been implemented in other modalities such as optical tomography. This paper has implemented Eminent Pixel Reconstruction in magnetic induction tomography applications and the performance is compared to Linear Back Projection based on the simulation of the fourteen types of simulated phantoms of homogenous and isotropic conductivity property. It was found that Eminent Pixel Reconstruction has produced better images relative to Linear Back Projection, however the images are still poor when the objects are located near to the excitation coil or sensor and it is worse when the distance between objects are near to each other. 2015-05-25T03:20:22Z 2015-05-25T03:20:22Z 2014 Article Jurnal Teknologi (Sciences and Engineering), vol. 69(8), 2014, pages 65-70 0127-9696 (P) 2180-3722 (O) http://www.jurnalteknologi.utm.my/index.php/jurnalteknologi/article/view/3298 http://dspace.unimap.edu.my:80/xmlui/handle/123456789/39949 en Penerbit UTM Press
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Image reconstruction algorithm
Isotropic
Low conductivity
Magnetic induction
Tomography
spellingShingle Image reconstruction algorithm
Isotropic
Low conductivity
Magnetic induction
Tomography
Zulkarnay, Zakaria
Ibrahim, Balkhis
Lee, Pick Yern
Nor Muzakkir, Nor Ayob
Mohd Hafiz, Fazalul Rahiman, Dr.
Mohd Zikrillah, Zawahirah
Ruzairi, Abdul Rahim, Prof. Dr.
Simulative study of two-phase homogenous and isotropic media imaging using magnetic induction tomography
description Link to publisher's homepage at http://www.penerbit.utm.my/
author2 zulkarnay@unimap.edu.my
author_facet zulkarnay@unimap.edu.my
Zulkarnay, Zakaria
Ibrahim, Balkhis
Lee, Pick Yern
Nor Muzakkir, Nor Ayob
Mohd Hafiz, Fazalul Rahiman, Dr.
Mohd Zikrillah, Zawahirah
Ruzairi, Abdul Rahim, Prof. Dr.
format Article
author Zulkarnay, Zakaria
Ibrahim, Balkhis
Lee, Pick Yern
Nor Muzakkir, Nor Ayob
Mohd Hafiz, Fazalul Rahiman, Dr.
Mohd Zikrillah, Zawahirah
Ruzairi, Abdul Rahim, Prof. Dr.
author_sort Zulkarnay, Zakaria
title Simulative study of two-phase homogenous and isotropic media imaging using magnetic induction tomography
title_short Simulative study of two-phase homogenous and isotropic media imaging using magnetic induction tomography
title_full Simulative study of two-phase homogenous and isotropic media imaging using magnetic induction tomography
title_fullStr Simulative study of two-phase homogenous and isotropic media imaging using magnetic induction tomography
title_full_unstemmed Simulative study of two-phase homogenous and isotropic media imaging using magnetic induction tomography
title_sort simulative study of two-phase homogenous and isotropic media imaging using magnetic induction tomography
publisher Penerbit UTM Press
publishDate 2015
url http://dspace.unimap.edu.my:80/xmlui/handle/123456789/39949
_version_ 1643799227104493568
score 13.211869