The comparative study between R-22 and R-410A as refrigerant in air conditioning applications

Access is limited to UniMAP community.

Saved in:
Bibliographic Details
Main Author: Soon, Kuok Hau
Other Authors: Salsuwanda Selamat
Format: Learning Object
Language:English
Published: Universiti Malaysia Perlis (UniMAP) 2013
Subjects:
Online Access:http://dspace.unimap.edu.my/xmlui/handle/123456789/24440
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimap-24440
record_format dspace
spelling my.unimap-244402013-04-23T08:00:29Z The comparative study between R-22 and R-410A as refrigerant in air conditioning applications Soon, Kuok Hau Salsuwanda Selamat Ozone (O3) Air conditioning system Refrigerant R-22 Refrigerant R-410A Access is limited to UniMAP community. Since the ozone hole was discovered in the late 1970s, a lot researches had been carried out to determine the main contribution to this phenomena. One of the main contributions is the refrigerant R-22. Previous researches showed that R-22 disintegrate the ozone molecules when chlorine atom reacted with ozone molecules, resulted in ozone depletion. In order to reduce the ozone depletion, R-22 was scheduled to be phased out and alternatives were determined to replace R-22. This study reports the thermal characteristic and environmental attributes of R-22 and R-410A refrigerants. The experiment was conducted in a test room in the School of Environmental Engineering, University Malaysia Perlis. The performances of both refrigerants were experimentally determined. The experimental data were taken every 15 minutes in 12 hours a day from 8 February to 15 March 2012. The average coefficient of performance (COP) was determined using the measured temperature of the cooled space and ambient temperature. Average COP for the R-22 and R-410A refrigerant were 4.8 and 6.3 respectively. The average power consumption for R-22 refrigerant and R-410A were 6.9 kilowatt and 5.6 kilowatt respectively. The experiment results indicate that R-410A refrigerant is economically preferable, more environmental friendly and has a better performance therefore it is an alternative solution for replacing the obsolete R-22 refrigerant. 2013-04-23T08:00:29Z 2013-04-23T08:00:29Z 2012-05 Learning Object http://hdl.handle.net/123456789/24440 en Universiti Malaysia Perlis (UniMAP) School of Environmental Engineering
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Ozone (O3)
Air conditioning system
Refrigerant R-22
Refrigerant R-410A
spellingShingle Ozone (O3)
Air conditioning system
Refrigerant R-22
Refrigerant R-410A
Soon, Kuok Hau
The comparative study between R-22 and R-410A as refrigerant in air conditioning applications
description Access is limited to UniMAP community.
author2 Salsuwanda Selamat
author_facet Salsuwanda Selamat
Soon, Kuok Hau
format Learning Object
author Soon, Kuok Hau
author_sort Soon, Kuok Hau
title The comparative study between R-22 and R-410A as refrigerant in air conditioning applications
title_short The comparative study between R-22 and R-410A as refrigerant in air conditioning applications
title_full The comparative study between R-22 and R-410A as refrigerant in air conditioning applications
title_fullStr The comparative study between R-22 and R-410A as refrigerant in air conditioning applications
title_full_unstemmed The comparative study between R-22 and R-410A as refrigerant in air conditioning applications
title_sort comparative study between r-22 and r-410a as refrigerant in air conditioning applications
publisher Universiti Malaysia Perlis (UniMAP)
publishDate 2013
url http://dspace.unimap.edu.my/xmlui/handle/123456789/24440
_version_ 1643794339397107712
score 13.222552