The comparative study between R-22 and R-410A as refrigerant in air conditioning applications
Access is limited to UniMAP community.
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Learning Object |
Language: | English |
Published: |
Universiti Malaysia Perlis (UniMAP)
2013
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my/xmlui/handle/123456789/24440 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-24440 |
---|---|
record_format |
dspace |
spelling |
my.unimap-244402013-04-23T08:00:29Z The comparative study between R-22 and R-410A as refrigerant in air conditioning applications Soon, Kuok Hau Salsuwanda Selamat Ozone (O3) Air conditioning system Refrigerant R-22 Refrigerant R-410A Access is limited to UniMAP community. Since the ozone hole was discovered in the late 1970s, a lot researches had been carried out to determine the main contribution to this phenomena. One of the main contributions is the refrigerant R-22. Previous researches showed that R-22 disintegrate the ozone molecules when chlorine atom reacted with ozone molecules, resulted in ozone depletion. In order to reduce the ozone depletion, R-22 was scheduled to be phased out and alternatives were determined to replace R-22. This study reports the thermal characteristic and environmental attributes of R-22 and R-410A refrigerants. The experiment was conducted in a test room in the School of Environmental Engineering, University Malaysia Perlis. The performances of both refrigerants were experimentally determined. The experimental data were taken every 15 minutes in 12 hours a day from 8 February to 15 March 2012. The average coefficient of performance (COP) was determined using the measured temperature of the cooled space and ambient temperature. Average COP for the R-22 and R-410A refrigerant were 4.8 and 6.3 respectively. The average power consumption for R-22 refrigerant and R-410A were 6.9 kilowatt and 5.6 kilowatt respectively. The experiment results indicate that R-410A refrigerant is economically preferable, more environmental friendly and has a better performance therefore it is an alternative solution for replacing the obsolete R-22 refrigerant. 2013-04-23T08:00:29Z 2013-04-23T08:00:29Z 2012-05 Learning Object http://hdl.handle.net/123456789/24440 en Universiti Malaysia Perlis (UniMAP) School of Environmental Engineering |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Ozone (O3) Air conditioning system Refrigerant R-22 Refrigerant R-410A |
spellingShingle |
Ozone (O3) Air conditioning system Refrigerant R-22 Refrigerant R-410A Soon, Kuok Hau The comparative study between R-22 and R-410A as refrigerant in air conditioning applications |
description |
Access is limited to UniMAP community. |
author2 |
Salsuwanda Selamat |
author_facet |
Salsuwanda Selamat Soon, Kuok Hau |
format |
Learning Object |
author |
Soon, Kuok Hau |
author_sort |
Soon, Kuok Hau |
title |
The comparative study between R-22 and R-410A as refrigerant in air conditioning applications |
title_short |
The comparative study between R-22 and R-410A as refrigerant in air conditioning applications |
title_full |
The comparative study between R-22 and R-410A as refrigerant in air conditioning applications |
title_fullStr |
The comparative study between R-22 and R-410A as refrigerant in air conditioning applications |
title_full_unstemmed |
The comparative study between R-22 and R-410A as refrigerant in air conditioning applications |
title_sort |
comparative study between r-22 and r-410a as refrigerant in air conditioning applications |
publisher |
Universiti Malaysia Perlis (UniMAP) |
publishDate |
2013 |
url |
http://dspace.unimap.edu.my/xmlui/handle/123456789/24440 |
_version_ |
1643794339397107712 |
score |
13.222552 |