Comparison on losses and flux distribution between two 3-phase distribution transformers 1000kVA assembled with air gap and without air gap of transformer core lamination

Link to publisher's homepage at http://ieeexplore.ieee.org

Saved in:
Bibliographic Details
Main Authors: Ismail, Daut, Dina Maizana, Maiz Ahmad, Shuhaimi, Zakaria, Soib, Taib
Format: Working Paper
Language:English
Published: Institute of Electrical and Electronics Engineering (IEEE) 2008
Subjects:
Online Access:http://dspace.unimap.edu.my/xmlui/handle/123456789/2299
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimap-2299
record_format dspace
spelling my.unimap-22992014-05-05T06:37:08Z Comparison on losses and flux distribution between two 3-phase distribution transformers 1000kVA assembled with air gap and without air gap of transformer core lamination Ismail, Daut Dina Maizana, Maiz Ahmad Shuhaimi, Zakaria Soib, Taib Transformer cores Flux distribution Power loss Transformers Iron loss Magnetic flux Harmonic distortion Link to publisher's homepage at http://ieeexplore.ieee.org This paper describes the result of an investigation on the effect of air gap of core lamination in two 3-phase distribution transformers 1000kVA. The investigation involves the variation of power loss, building factor, the third harmonic distortion and flux leakages. The power loss and flux distribution have been measured using no load test in two types of model of setting of core built from the same size and type of M5 (CGO) grades material of laminations. And the loss of the transformer core without air gap of layer joint of core lamination is 2.75% better than the loss of the transformer core with air gap of layer joint of core lamination at 1.7T, 50 Hz. The flux leakage at the corner joint in the core without air gap of layer joint of lamination is lower than that in the transformer core with air gap of layer joint of lamination, over the whole flux density range. The third harmonic distortion of flux is smaller in the transformer core without air gap of layer joint of lamination and larger in the transformer core with air gap of layer joint of core lamination. Using the type without air gap of layer joint of lamination in transformer core is more efficient than the other types of transformer core lamination. 2008-09-19T02:03:48Z 2008-09-19T02:03:48Z 2007-12-06 Working Paper p.1-4 978-1-4244-1434-5 http://hdl.handle.net/123456789/2299 http://ieeexplore.ieee.org/xpls/abs_all.jsp?=&arnumber=4603874 en Proceedings of the Asia - Pacific Conference on Applied Electromagnetics (APACE 2007) Institute of Electrical and Electronics Engineering (IEEE)
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Transformer cores
Flux distribution
Power loss
Transformers
Iron loss
Magnetic flux
Harmonic distortion
spellingShingle Transformer cores
Flux distribution
Power loss
Transformers
Iron loss
Magnetic flux
Harmonic distortion
Ismail, Daut
Dina Maizana, Maiz Ahmad
Shuhaimi, Zakaria
Soib, Taib
Comparison on losses and flux distribution between two 3-phase distribution transformers 1000kVA assembled with air gap and without air gap of transformer core lamination
description Link to publisher's homepage at http://ieeexplore.ieee.org
format Working Paper
author Ismail, Daut
Dina Maizana, Maiz Ahmad
Shuhaimi, Zakaria
Soib, Taib
author_facet Ismail, Daut
Dina Maizana, Maiz Ahmad
Shuhaimi, Zakaria
Soib, Taib
author_sort Ismail, Daut
title Comparison on losses and flux distribution between two 3-phase distribution transformers 1000kVA assembled with air gap and without air gap of transformer core lamination
title_short Comparison on losses and flux distribution between two 3-phase distribution transformers 1000kVA assembled with air gap and without air gap of transformer core lamination
title_full Comparison on losses and flux distribution between two 3-phase distribution transformers 1000kVA assembled with air gap and without air gap of transformer core lamination
title_fullStr Comparison on losses and flux distribution between two 3-phase distribution transformers 1000kVA assembled with air gap and without air gap of transformer core lamination
title_full_unstemmed Comparison on losses and flux distribution between two 3-phase distribution transformers 1000kVA assembled with air gap and without air gap of transformer core lamination
title_sort comparison on losses and flux distribution between two 3-phase distribution transformers 1000kva assembled with air gap and without air gap of transformer core lamination
publisher Institute of Electrical and Electronics Engineering (IEEE)
publishDate 2008
url http://dspace.unimap.edu.my/xmlui/handle/123456789/2299
_version_ 1643787526107824128
score 13.222552