Automotif Transfer Scheme (ATS) experience in Tenaga Nasional Berhad Distribution Negeri Perak
Link to publisher’s homepage at http://www.myiem.org.my/
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
The Institution of Engineers, Malaysia
2011
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my/xmlui/handle/123456789/15688 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-15688 |
---|---|
record_format |
dspace |
spelling |
my.unimap-156882011-11-15T06:29:27Z Automotif Transfer Scheme (ATS) experience in Tenaga Nasional Berhad Distribution Negeri Perak Mohd. Hashimi, Hashim Megat Ahmad Fauzi, Megat Rasidin Sahari, Adullah Electricity Automatic Transfer Scheme (ATS) Tenaga Nasional Berhad (TNB) Perak Cable Link to publisher’s homepage at http://www.myiem.org.my/ Electricity is distributed to most large power/important consumers via, at least, two feeders of underground/ overhead cables. Generally, the main cable is operational while the other is on standby as backup with the bus-section CLOSE. Other configurations such as having both incomers CLOSE and the bus-section OPEN, and no bus-section are also practised. In the event of a fault in the main cable, the switch to transfer load to the backup cable will be done either manually or remotely via control centres. The process might take anywhere from one hour or longer especially during peak hours or night time. Automatic Transfer Scheme (AT S) is designed to perform safely the automatic switching to minimise interruption down to approximately 1 sec or faster. Remedial work on the faulty cable or equipment can be done at a later time. System normalisation is designed to be done manually. 2011-11-15T06:29:27Z 2011-11-15T06:29:27Z 2008-07 Article p.16, 18 0126-9909 http://www.myiem.org.my/content/iem_bulletin_2008-183.aspx http://hdl.handle.net/123456789/15688 en Jurutera 2008 (7) The Institution of Engineers, Malaysia |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Electricity Automatic Transfer Scheme (ATS) Tenaga Nasional Berhad (TNB) Perak Cable |
spellingShingle |
Electricity Automatic Transfer Scheme (ATS) Tenaga Nasional Berhad (TNB) Perak Cable Mohd. Hashimi, Hashim Megat Ahmad Fauzi, Megat Rasidin Sahari, Adullah Automotif Transfer Scheme (ATS) experience in Tenaga Nasional Berhad Distribution Negeri Perak |
description |
Link to publisher’s homepage at http://www.myiem.org.my/ |
format |
Article |
author |
Mohd. Hashimi, Hashim Megat Ahmad Fauzi, Megat Rasidin Sahari, Adullah |
author_facet |
Mohd. Hashimi, Hashim Megat Ahmad Fauzi, Megat Rasidin Sahari, Adullah |
author_sort |
Mohd. Hashimi, Hashim |
title |
Automotif Transfer Scheme (ATS) experience in Tenaga Nasional Berhad Distribution Negeri Perak |
title_short |
Automotif Transfer Scheme (ATS) experience in Tenaga Nasional Berhad Distribution Negeri Perak |
title_full |
Automotif Transfer Scheme (ATS) experience in Tenaga Nasional Berhad Distribution Negeri Perak |
title_fullStr |
Automotif Transfer Scheme (ATS) experience in Tenaga Nasional Berhad Distribution Negeri Perak |
title_full_unstemmed |
Automotif Transfer Scheme (ATS) experience in Tenaga Nasional Berhad Distribution Negeri Perak |
title_sort |
automotif transfer scheme (ats) experience in tenaga nasional berhad distribution negeri perak |
publisher |
The Institution of Engineers, Malaysia |
publishDate |
2011 |
url |
http://dspace.unimap.edu.my/xmlui/handle/123456789/15688 |
_version_ |
1643791153546395648 |
score |
13.222552 |