Finite element study on the micromotion of cementless total hip arthroplasty

Link to publisher's homepage at www.ifmbe.org/

Saved in:
Bibliographic Details
Main Authors: Mohd. Yusof, Baharuddin, Mohammed Rafiq, Abdul Kadir
Other Authors: myusof@unimap.edu.my
Format: Working Paper
Language:English
Published: International Federation for Medical and Biological Engineering 2011
Subjects:
Online Access:http://dspace.unimap.edu.my/xmlui/handle/123456789/10451
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimap-10451
record_format dspace
spelling my.unimap-104512011-01-10T04:36:58Z Finite element study on the micromotion of cementless total hip arthroplasty Mohd. Yusof, Baharuddin Mohammed Rafiq, Abdul Kadir myusof@unimap.edu.my Micromotion Stability Total Hip Arthroplasty Link to publisher's homepage at www.ifmbe.org/ Major problem associated with the cementless design is the lack of stability. Several design features were introduced to provide the much needed stability for bone integration. These include fins, fiber mesh, beads, indentations and collars. The use of collar has been a subject of controversy with mixed reports of clinical outcomes. In this study, the effectiveness of collar in terms of providing stability was analysed using finite element method. Three dimensional model of a human femur was constructed from CT dataset and hip arthroplasty was simulated. With an applied joint contact load simulating physiological gait, micromotion of the implant relative to the bone was calculated via an experimentally validated algorithm. Results showed that collar did not improve stability of the whole stem but only around the medial calcar region. 2011-01-10T04:05:31Z 2011-01-10T04:05:31Z 2010-08-01 Working Paper Vol. 31, p. 605-607 978-3-5407-9038-9 1680-0737 http://www.springerlink.com/content/v82mqw0v36060461/fulltext.pdf http://hdl.handle.net/123456789/10451 en Proceedings of the International Federation for Medical and Biological Engineering (IFMBE) 2010 International Federation for Medical and Biological Engineering
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Micromotion
Stability
Total Hip Arthroplasty
spellingShingle Micromotion
Stability
Total Hip Arthroplasty
Mohd. Yusof, Baharuddin
Mohammed Rafiq, Abdul Kadir
Finite element study on the micromotion of cementless total hip arthroplasty
description Link to publisher's homepage at www.ifmbe.org/
author2 myusof@unimap.edu.my
author_facet myusof@unimap.edu.my
Mohd. Yusof, Baharuddin
Mohammed Rafiq, Abdul Kadir
format Working Paper
author Mohd. Yusof, Baharuddin
Mohammed Rafiq, Abdul Kadir
author_sort Mohd. Yusof, Baharuddin
title Finite element study on the micromotion of cementless total hip arthroplasty
title_short Finite element study on the micromotion of cementless total hip arthroplasty
title_full Finite element study on the micromotion of cementless total hip arthroplasty
title_fullStr Finite element study on the micromotion of cementless total hip arthroplasty
title_full_unstemmed Finite element study on the micromotion of cementless total hip arthroplasty
title_sort finite element study on the micromotion of cementless total hip arthroplasty
publisher International Federation for Medical and Biological Engineering
publishDate 2011
url http://dspace.unimap.edu.my/xmlui/handle/123456789/10451
_version_ 1643789907056918528
score 13.222552