Unstructured electrical impedance tomography using ad hoc sensor node

Electrical Impedance Tomography (EIT) is a simple solution for obtaining information about the interior of an object or a process through performing voltage measurements, whereby interior conductivity distribution in an object can be reconstructed in a form of tomograms. EIT has many applications in...

Full description

Saved in:
Bibliographic Details
Main Author: Abbas Ibrahim Mbulwa
Format: Thesis
Language:English
English
Published: 2019
Subjects:
Online Access:https://eprints.ums.edu.my/id/eprint/36207/1/24%20PAGES.pdf
https://eprints.ums.edu.my/id/eprint/36207/2/FULLTEXT.pdf
https://eprints.ums.edu.my/id/eprint/36207/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ums.eprints.36207
record_format eprints
spelling my.ums.eprints.362072023-07-27T03:14:12Z https://eprints.ums.edu.my/id/eprint/36207/ Unstructured electrical impedance tomography using ad hoc sensor node Abbas Ibrahim Mbulwa TA630-695 Structural engineering (General) Electrical Impedance Tomography (EIT) is a simple solution for obtaining information about the interior of an object or a process through performing voltage measurements, whereby interior conductivity distribution in an object can be reconstructed in a form of tomograms. EIT has many applications in areas such as medical, geophysical, and industrial process, where it has shown various potential over existing tomographic modalities. However, the main drawback has been low spatial resolution towards the center of the object. The objective of this project is to obtain EIT measurements from the interior of the object under test, through the employment of ad hoe internal electrodes, in an effort to acquire data that were unobtainable through conventional EIT system. To achieve this objective, a prototype of an ad hoe EIT sensor is designed. The ad hoe EIT sensor is battery powered. The sensor node is attached with two pairs of electrodes. The sensor integrated circuit is designed to enable current injection and voltage measurement from within the medium using the two pairs of electrodes. One pair performs current injection, while another pair measures localized voltage difference. The role of the two pairs are interchangeable by using analog multiplexers. The sensor integrated system consisting of a current source, voltage sense, multiplexers, and microcontroller unit, were simulated and tested. The ad hoe sensor prototype was experimented on homogeneous medium and inhomogeneous medium of tap water and saline. The results show a feasible means of acquiring EIT data from the interior of the object. 2019 Thesis NonPeerReviewed text en https://eprints.ums.edu.my/id/eprint/36207/1/24%20PAGES.pdf text en https://eprints.ums.edu.my/id/eprint/36207/2/FULLTEXT.pdf Abbas Ibrahim Mbulwa (2019) Unstructured electrical impedance tomography using ad hoc sensor node. Masters thesis, Universiti Malaysia Sabah.
institution Universiti Malaysia Sabah
building UMS Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sabah
content_source UMS Institutional Repository
url_provider http://eprints.ums.edu.my/
language English
English
topic TA630-695 Structural engineering (General)
spellingShingle TA630-695 Structural engineering (General)
Abbas Ibrahim Mbulwa
Unstructured electrical impedance tomography using ad hoc sensor node
description Electrical Impedance Tomography (EIT) is a simple solution for obtaining information about the interior of an object or a process through performing voltage measurements, whereby interior conductivity distribution in an object can be reconstructed in a form of tomograms. EIT has many applications in areas such as medical, geophysical, and industrial process, where it has shown various potential over existing tomographic modalities. However, the main drawback has been low spatial resolution towards the center of the object. The objective of this project is to obtain EIT measurements from the interior of the object under test, through the employment of ad hoe internal electrodes, in an effort to acquire data that were unobtainable through conventional EIT system. To achieve this objective, a prototype of an ad hoe EIT sensor is designed. The ad hoe EIT sensor is battery powered. The sensor node is attached with two pairs of electrodes. The sensor integrated circuit is designed to enable current injection and voltage measurement from within the medium using the two pairs of electrodes. One pair performs current injection, while another pair measures localized voltage difference. The role of the two pairs are interchangeable by using analog multiplexers. The sensor integrated system consisting of a current source, voltage sense, multiplexers, and microcontroller unit, were simulated and tested. The ad hoe sensor prototype was experimented on homogeneous medium and inhomogeneous medium of tap water and saline. The results show a feasible means of acquiring EIT data from the interior of the object.
format Thesis
author Abbas Ibrahim Mbulwa
author_facet Abbas Ibrahim Mbulwa
author_sort Abbas Ibrahim Mbulwa
title Unstructured electrical impedance tomography using ad hoc sensor node
title_short Unstructured electrical impedance tomography using ad hoc sensor node
title_full Unstructured electrical impedance tomography using ad hoc sensor node
title_fullStr Unstructured electrical impedance tomography using ad hoc sensor node
title_full_unstemmed Unstructured electrical impedance tomography using ad hoc sensor node
title_sort unstructured electrical impedance tomography using ad hoc sensor node
publishDate 2019
url https://eprints.ums.edu.my/id/eprint/36207/1/24%20PAGES.pdf
https://eprints.ums.edu.my/id/eprint/36207/2/FULLTEXT.pdf
https://eprints.ums.edu.my/id/eprint/36207/
_version_ 1772812713493266432
score 13.211869