Optimisation of an electrochemical sensor based on bare gold electrode for detection of aluminium ion

In this work, an electrochemical method for detection of trace amount of aluminium (Al3+), a heavy metal ion, based on a bare gold electrode (AuE) was developed. Current responses of the AuE under various type of electrolytes, redox indicators, pH, scan rate and accumulation time were investigated...

Full description

Saved in:
Bibliographic Details
Main Authors: Gilbert Ringgit, Shafiquzzaman Siddiquee, Suryani Saallah, Mohammad Tamrin Mohamad Lal
Format: Article
Language:English
English
Published: Borneo International Journal of Biotechnology (BIJB) 2020
Subjects:
Online Access:https://eprints.ums.edu.my/id/eprint/27409/1/Optimisation%20of%20an%20electrochemical%20sensor%20based%20on%20bare%20gold%20electrode%20for%20detection%20of%20aluminium%20ion%20abstract.pdf
https://eprints.ums.edu.my/id/eprint/27409/2/Optimisation%20of%20an%20electrochemical%20sensor%20based%20on%20bare%20gold%20electrode%20for%20detection%20of%20aluminium%20ion%20fulltext.pdf
https://eprints.ums.edu.my/id/eprint/27409/
https://doi.org/10.51200/bijb.vi.2203
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In this work, an electrochemical method for detection of trace amount of aluminium (Al3+), a heavy metal ion, based on a bare gold electrode (AuE) was developed. Current responses of the AuE under various type of electrolytes, redox indicators, pH, scan rate and accumulation time were investigated using cyclic voltammetry (CV) method to obtain the optimum conditions for Al3+ detection. The sensing properties of the AuE towards the target ion with different concentrations were investigated using differential pulse voltammetry (DPV) method. From the CV results, the optimal conditions for the detection of Al3+ were Tris-HCl buffer (0.1 M, pH 2) supported by 5 mM Prussian blue with scan rate and accumulation time respectively of 100 mVs−1 and 15 s. Under the optimum conditions, the DPV method was detected with different concentrations of aluminium ion ranging from 0.2 to 1.0 ppm resulted in a good linear regression r² = 0.9806. This result suggests that the optimisation of the basic parameters in electrochemical detection using AuE is crucial before further modification of the Au-electrode to improve the sensitivity and selectivity especially for the low concentration of ion detection. The developed method has a great potential for rapid detection of heavy metal ion (Al3+) in drinking water samples.